Instrukcja obsługi Kern BFN 3T-3AM

Kern lustrzanka BFN 3T-3AM

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Kern BFN 3T-3AM (2 stron) w kategorii lustrzanka. Ta instrukcja była pomocna dla 5 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/2
KERN & SOHN GmbH · Ziegelei 1 · 72336 Balingen · Germany · Tel. +49 7433 9933 - 0 · www.kern-sohn.com · info@kern-sohn.com
BALANCES & TEST SERVICE 2024
Floor Scales, Pallet Scales, Drive-Through Scales
BALANCES & TEST SERVICE 2024
* The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by KERN & SOHN GmbH
is under license. Other trademarks and trade names are those of their respective owners.
Internal adjusting
Quick setting up of the
balance‘s accuracy with
internal adjusting
weight (motor driven)
Adjusting program CAL
For quick setting up of
the balance‘s accuracy.
External adjusting weight
required
EasyTouch
Suitable for the connection,
data transmission and
control through PC or tablet
Memory
Balance memory capacity,
e.g. for article data,
weighing data, tare weights,
PLU etc.
ALIBI
Alibi memory
Secure, electronic
archiving of weighing
results, complying with the
2014/31/EU standard.
KERN Universal Port
(KUP)
allows the connection of
external KUP interface
adapters, e.g. RS-232,
RS-485, SB, Bluetooth,
WIFI, Analogue, Ethernet
etc. for the exchange of
data and control com-
mands, without installation
effort
RS-232 Data interface
To connect the balance to a
printer, PC or network
RS-485 Data interface
To connect the balance
to a printer, PC or other
peripherals. Suitable for
data transfer over large
distances. Network in bus
topology is possible
USB Data interface
To connect the balance
to a printer, PC or other
peripherals
Bluetooth* Data interface
To transfer data from the
balance to a printer, PC or
other peripherals
WIFI Data interface
To transfer data from the
balance to a printer, PC or
other peripherals
Control outputs
(optocoupler, digital I/O)
To connect relays, signal
lamps, valves, etc.
Analogue interface
to connect a suitable
peripheral device for
analogue processing of
the measurements
Interface for second
balance
For direct connection of a
second balance
Network interface
For connecting the scale to
an Ethernet network
KERN Communication
Protocol (KCP)
It is a standardized
interface command set for
KERN balances and other
instru ments, which allows
retrieving and controlling
all relevant parameters and
functions of the device.
KERN devices featuring KCP
are thus easily integrated
with computers, industrial
controllers and other digital
systems
GLP/ISO log intern
The balance displays
weight, date and time,
independent of a printer
connection
GLP/ISO log Printer
With weight, date and time.
Only with KERN printers.
Piece counting
Reference quantities
selectable.
Display can be switched
from piece to weight
Recipe level A
The weights of the recipe
ingredients can be added
together and the total
weight of the recipe can be
printed out
Recipe level B
Internal memory for
complete recipes with
name and target value of
the recipe ingredients. User
guidance through display
Totalising level A
The weights of similar items
can be added together and
the total can be printed out
Percentage determination
Determining the deviation
in % from the target value
(100 %)
Weighing units
Can be switched to e.g.
nonmetric units. See
balance model. Please refer
to KERN‘s website for more
details
Weighing with tolerance
range (Checkweighing)
Upper and lower limit-
ing can be programmed
individually, e.g. for sorting
and dosing. The process
is supported by an audible
or visual signal, see the
relevant model
Hold function
(Animal weighing program)
When the weighing con-
ditions are un stable, a
stable weight is calculated
as an average value
Protection against dust
and water splashes IPxx
The type of protection is
shown in the pictogram
Suspended weighing
Load support with hook
on the underside of the
balance
Battery operation
Ready for battery opera-
tion. The battery type is
specified for each device
Rechargeable
battery pack
Rechargeable set
MULTI
Universal plug-in power
supply
with universal input and
optional input socket
adapters for
A) EU, CH, GB
B) EU, CH, GB, US
C) EU, CH, GB, US, AUS
Plug-in power supply
230V/50Hz in standard
version for EU, CH.
On request GB, USA or AUS
version available
Integrated power
supply unit
Integrated in balance.
230V/50Hz standard EU.
More standards e.g.
GB, USA or AUS on request
Weighing principle
Strain gauges
Electrical resistor on an
elastic deforming body
Weighing principle
Tuning fork
A resonating body is
electromagnetically excited,
causing it to oscillate
Weighing principle
Electromagnetic force
compensation
Coil inside a permanent
magnet. For the most
accurate weighings
Weighing principle
Single cell technology
Advanced version of
the force compensation
principle with the highest
level of precision
Conformity Assessment
The time required for
conformity assessment is
specified in the pictogram
DAkkS calibration
possible (DKD)
The time required for
DAkkS calibration
is shown in days in the
pictogram
Factory calibration (ISO)
The time required for
Factory calibration is shown
in days in the pictogram
Package shipment
The time required for
internal shipping prepa-
rations is shown in days
in the pictogram
Pallet shipment
The time required for
internal shipping prepa-
rations is shown in days
in the pictogram
KERN Pictograms
KERN & SOHN GmbH · Ziegelei 1 · 72336 Balingen · Germany · Tel. +49 7433 9933 - 0 · www.kern-sohn.com · info@kern-sohn.com


Specyfikacje produktu

Marka: Kern
Kategoria: lustrzanka
Model: BFN 3T-3AM

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Kern BFN 3T-3AM, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje lustrzanka Kern

Kern

Kern IOC 100K-2M Instrukcja

9 Października 2024
Kern

Kern IFS 30K0.2DL Instrukcja

9 Października 2024
Kern

Kern IFS 100K-2LM Instrukcja

9 Października 2024
Kern

Kern IFS 10K-3LM Instrukcja

9 Października 2024
Kern

Kern HDB 10K-2XL Instrukcja

9 Października 2024
Kern

Kern HFM 10T1 Instrukcja

9 Października 2024
Kern

Kern HFM 3T0.5 Instrukcja

9 Października 2024
Kern

Kern HFC 3T-3 Instrukcja

9 Października 2024
Kern

Kern HFA 3T-3 Instrukcja

9 Października 2024
Kern

Kern HFA 1T-4 Instrukcja

9 Października 2024

Instrukcje lustrzanka

Najnowsze instrukcje dla lustrzanka