Instrukcja obsługi Kenmore 9082


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Kenmore 9082 (1 stron) w kategorii Niesklasyfikowane. Ta instrukcja była pomocna dla 5 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/1
Water Supply Potable City or Well
Water Pressure 30 - 120 psi (207 - 827 kPa)
Water Temperature 33° - 100°F (0.6° - 37.8° C)
Service Flow Rate 0.75 GPM (2.84 L/min.) @ 60 psi.
PERFORMANCE DATA SHEETS
System tested and certified by NSF International against NSF/
ANSI Standard 42, 53, 401 and CSA B483.1 for the reduction of
contaminants specified on the Performance Data Sheet.
This system has been tested according to NSF/ANSI Standards 42, 53 and 401 for the reduction of the substances listed below. The concentration
of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving
the system, as specified in NSF/ANSI Standards 42, 53, and 401.
Chlorine Taste/Odor 2.0 mg/L ± 10% 50% reduction 97.0%
Particulate Class I* At least 10,000 particles/mL 85% reduction >99.9%
Lead***: @ pH 6.5 / @ pH 8.5 0.150 mg/L ± 10% 0.010 mg/L >99.3% / >98.6%
Benzene 0.015 mg/L ± 10% 0.005 mg/L 93.8%
p-Dichlorobenzene 0.225 mg/L ± 10% 0.075 mg/L 99.8%
Carbofuran 0.080 mg/L ± 10% 0.040 mg/L 81.9%
Toxaphene 0.015 ± 10% 0.003 mg/L >95%
Atrazine 0.009 mg/L ± 10% 0.003 mg/L 87.0%
Asbestos 107 to 108 bers/L†† 99% >99%
Live Cysts† 50,000/L min. 99.95% >99.99%
Turbidity 11 NTU ± 10% 0.5 NTU 96.9%
Lindane 0.002 ± 10% 0.0002 mg/L >99.2%
Tetrachloroethylene 0.015 mg/L ± 10% 0.005 mg/L 96.6%
o-Dichlorobenzene 1.8 mg/L ± 10% 0.60 mg/L 92.3%
Ethylbenzene 2.1 mg/L ± 10% 0.70 mg/L >86.9%
1,2,4-Trichlorobenzene 0.210 mg/L ± 10% 0.07 mg/L 99.8%
2,4 - D 0.210 mg/L ± 10% 0.07 mg/L 88.5%
Styrene 2.0 mg/L ± 10% 0.1 mg/L 99.6%
Toluene 3.0 mg/L ± 10% 1.0 mg/L 93.5%
Endrin 0.006 mg/L ± 10% 0.002 mg/L 81.7%
Atenolol 200 ± 20% 30 ng/L 95.7%
Trimethoprim 140 ± 20% 20 ng/L 96.1%
Linuron 140 ± 20% 20 ng/L 96.3%
It is essential that operational, maintenance, and filter replacement
requirements be carried out for the product to perform as advertised.
Property damage can occur if all instructions are not followed.
The disposable cartridge must be changed at least every 6 months.
Use replacement filter P9RFKB2L, Part #46 9082. 2016 suggested
retail price of $54.99 U.S.A./$54.99 Canada. Prices are subject to
change without notice.
The filter monitor system measures the amount of water that passes
through the filter and alerts you when it is time to replace the filter.
Refer to the “Using the Controls” or “Water Filtration System” section
(in the User Instructions or User Guide) to learn how to check the
water filter status.
After changing the water filter, flush the water system. See “Water
and Ice Dispensers” or “Water Dispenser” in the User Instructions or
User Guide.
These contaminants are not necessarily in your water supply. While
testing was performed under standard laboratory conditions, actual
performance may vary.
* Class I particle size: >0.5 to <1 um
Based on the use of Cryptosporidium parvum oocysts
†† Fibers greater than 10 um in length
® NSF is a registered trademark of NSF International.
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.75 gpm (2.84 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C
to 22°C). Rated service capacity = 200 gallons (757 liters).
The compounds certified under NSF 401 have been deemed as “emerging compounds/incidental contaminants.” Emerging compounds/incidental
contaminants are those compounds that have been detected in drinking water supplies at trace levels. While occurring at only trace levels, these
compounds can affect the public acceptance/perception of drinking water quality.
The product is for cold water use only.
The water system must be installed in compliance with state and
local laws and regulations.
Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used on disinfected
waters that may contain filterable cysts. EPA Est. No.
082047-TWN-
001
Refer to the “Warranty” section for the Manufacturer’s limited
warranty, name and telephone number.


Specyfikacje produktu

Marka: Kenmore
Kategoria: Niesklasyfikowane
Model: 9082

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Kenmore 9082, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Kenmore

Kenmore

Kenmore DS4030 Instrukcja

3 Października 2024
Kenmore

Kenmore KW3010 Instrukcja

3 Października 2024
Kenmore

Kenmore DU5080 Instrukcja

3 Października 2024
Kenmore

Kenmore KW3030 Instrukcja

3 Października 2024
Kenmore

Kenmore DU4080 Instrukcja

3 Października 2024
Kenmore

Kenmore DS4090 Instrukcja

3 Października 2024
Kenmore

Kenmore DU3018 Instrukcja

3 Października 2024
Kenmore

Kenmore KW2005 Instrukcja

3 Października 2024
Kenmore

Kenmore DS4020 Instrukcja

3 Października 2024
Kenmore

Kenmore BC3005 Instrukcja

3 Października 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024