Instrukcja obsługi JUNG ME5232S


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla JUNG ME5232S (4 stron) w kategorii Niesklasyfikowane. Ta instrukcja była pomocna dla 3 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/4
Centre plate with anti lock-out function, Centre plate with anti lock-out
function and sensor connection
Blinds Management
Centre plate with anti lock-out function
Art. No. : ..5232..
Centre plate with anti lock-out function and sensor connection
Art. No. : ..5232 S..
Operating instructions
1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Danger of electric shock. Always disconnect before carrying out work on the devise or
load. At the same time, take into account all circuit breakers that supply dangerous
voltage to the device or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage.
These instructions are an integral part of the product, and must remain with the end
customer.
2 Device components
Figure 1: Device components
(1) Venetian blind control
(2) Frame
(3) Cover
(4) Status LED
3 Function
Intended use
- Operation of electrically-driven blinds, shutters and awnings
- Operation on control of the Venetian blind control system
Product characteristics
- Status LED
- Lock-out protection
- The individual moving time from the upper end position is storable
1/4
32550723
J:0082550723 16.05.2014
Additional functions for the cover with sensor connection
- Evaluation of a sun sensor
- Brightness threshold adjustable
- Automatic recognition of an outdoor sensor during the first sensor run
Sun protection function for cover with sensor evaluation
The connection of a sun sensor enables automatic shading when it is very bright outside. The
brightness threshold that controls the sun protection can be adjusted on the cover. If the
measured brightness exceeds the predefined brightness threshold for more than 2 minutes, the
Venetian blind moves downwards. The previously stored individual moving time is executed for
an outdoor sensor. The stop position is determined by the sun sensor for an indoor sensor.
iThe sun protection function is only activated if the Venetian blind has been moved to the
upper end position and the control has deactivated automatically after 2 minutes. Each
manual operation deactivates the sun protection.
If the brightness threshold is fallen short of for more than 15 minutes, the Venetian blind moves
back to the upper end position.
4 Operation
Moving the Venetian blind
oPress top or bottom of cover for longer than one second.
The Venetian blind moves in the desired direction to the end position or stops when the
button is pressed again.
Adjusting the slats
oPress top or bottom of cover for shorter than one second.
The slat position changes in the desired direction for as long as the button is pressed.
Activating lock-out protection
The lock-out protection prevents the Venetian blind from automatically moving down
unintentionally. Shutting down on site via the sensors or extensions is disabled.
oPress top of cover for longer than 4 seconds.
Status LED is illuminated. Venetian blind moves to the upper end position, the lock-out
protection is activated.
Deactivating lock-out protection
oPress top button briefly.
Status LED goes out.
The lock-out protection is deactivated.
iAfter a power failure, the lock-out protection is deactivated.
Saving individual moving time
If a Venetian blind should not move to the lower end position "ventilation function" or an outdoor
sensor is used, a shorter moving time can be stored. A time between 0.5 seconds and 2
minutes can be stored.
oPress cover over entire surface for longer than 4 seconds.
The Status LED flashes. The Venetian blind moves automatically to the upper end position.
oKeep the cover pressed in the direction until the Venetian blind is in the desired position.o
oRelease cover.
Venetian blind stops.
oPress cover over entire surface for at least 1 second to store the moving time.
- Or -
oPress cover or to discard the moving time.o n
The storage mode is exited automatically and the LED ceases to be illuminated.
2/4
32550723
J:0082550723 16.05.2014
Blinds Management
Centre plate with anti lock-out function, Centre plate with anti lock-out
function and sensor connection
iThe individual moving time remains permanently stored. The old moving time will be
replaced if a new moving time is stored.
iTo execute the individual moving time, the Venetian blind must be moved to the upper end
position and switch off there automatically after 2 minutes.
5 Information for electrically skilled persons
5.1 Fitting and electrical connection
Mounting and connecting
DANGER!
Electrical shock when live parts are touched.
Electrical shocks can be fatal.
Before carrying out work on the device or load, disengage all the
corresponding circuit breakers. Cover up live parts in the working environment.
The Venetian blind control is mounted and connected properly (see instructions for the relevant
Venetian blind control).
oInstall sun sensor for covers with sensor connection and connect to terminal block (see
instructions for the sensors and control).
oAdjust brightness threshold (see following chapter).
iConnect the sun sensor with the correct polarity. If a sensor is connected with reversed
polarity, this will result in malfunctions. It might not be possible to operate the cover any
more.
oMount cover (3) with frame (2) onto the Venetian blind control (1) (figure 1).
Adjusting brightness threshold for cover with sensor evaluation
Figure 2: Back of cover: Adjuster for brightness threshold
The brightness threshold can be adjusted within a range of approx. 5,000 Lux "small sun" to
approx 80,000 Lux "large sun" using the adjuster (5) on the back of the cover (figure 2). The
adjuster is preset to approx. 15,000 Lux at the factory.
oAdjust the brightness threshold to the required value. Adjust the brightness threshold value
after commissioning if necessary.
3/4
32550723
J:0082550723 16.05.2014
Blinds Management
Centre plate with anti lock-out function, Centre plate with anti lock-out
function and sensor connection


Specyfikacje produktu

Marka: JUNG
Kategoria: Niesklasyfikowane
Model: ME5232S

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z JUNG ME5232S, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane JUNG

JUNG

JUNG 531KO5EUM24 Instrukcja

8 Października 2024
JUNG

JUNG 531KO5EUM230 Instrukcja

8 Października 2024
JUNG

JUNG 534KO5EUD2 Instrukcja

8 Października 2024
JUNG

JUNG 531KO6EUM24 Instrukcja

8 Października 2024
JUNG

JUNG IPZ1000REG Instrukcja

7 Października 2024
JUNG

JUNG BTLC1521FS Instrukcja

25 Września 2024
JUNG

JUNG BTME1521FS Instrukcja

25 Września 2024
JUNG

JUNG BTLC1521FSE Instrukcja

25 Września 2024
JUNG

JUNG BTES1521FSE-L Instrukcja

25 Września 2024
JUNG

JUNG BTLS1521FSE Instrukcja

25 Września 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024