Instrukcja obsługi JUNG ABAS5232FS

JUNG Niesklasyfikowane ABAS5232FS

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla JUNG ABAS5232FS (7 stron) w kategorii Niesklasyfikowane. Ta instrukcja była pomocna dla 2 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/7
Centre plate with radio receiver, Centre plate with radio receiver and
sensor connection
Blinds Management
Centre plate with radio receiver
Art. No. : ..5232F..
Centre plate with radio receiver and sensor connection
Art. No. : ..5232FS..
Operating instructions
1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Danger of electric shock. Always disconnect before carrying out work on the devise or
load. In so doing, take all the circuit breakers into account, which support dangerous
voltages to the device and or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage.
The radio communication takes place via a non-exclusively available transmission path,
and is therefore not suitable for safety-related applications, such as emergency stop and
emergency call.
These instructions are an integral part of the product, and must remain with the end
customer.
2 Device components
Figure 1: Device components
(1) Venetian blind control
(2) Frame
(3) Radio cover
3 Function
System information
By statute, the transmitting power, the reception characteristics and the antenna cannot be
changed.
The range of a radio system from the transmitter to the receiver depends on various
circumstances.
The range of the system can be optimised by selecting the optimal installation location, taking
into account the structural circumstances.
1/7
32524333
J0082524333 13.09.2016
Figure 2: Reduced range due to structural obstacles
Example of penetration of various materials:
Material Penetration
Wood, Plaster, Plasterboard approx. 90%
Brick, Chipboard approx. 70%
Reinforced concrete approx. 30%
Metal, Metal grid approx. 10%
Rain, Snow approx. 1-40%
Intended use
- Manual and radio-controlled operation of electrically-driven Venetian blinds, shutters and
awnings
- Operation with suitable radio transmitters
- Operation on insert of the Venetian blind management system
Product characteristics
- End positions of the Venetian blind can be called up via light scenes
Additional functions for the cover with sensor connection
- Connection of a sun sensor (Accessories)
- Brightness threshold settable
Sun protection function for cover with sensor connection
The connection of a sun sensor (accessory) enables automatic shading when it is very bright
outside. The brightness threshold that controls the sun protection can be adjusted on the cover.
If the measured brightness exceeds the predefined brightness threshold for more than
2 minutes, the Venetian blind moves to the position defined by the sun sensor.
iThe sun protection can first be activated if the Venetian blind has been moved to the upper
end position and deactivated automatically after 2 minutes. Each manual or radio operation
deactivates the sun protection.
If the brightness threshold is fallen short of for more than 15 minutes, the Venetian blind moves
back to the upper end position.
4 Operation
Moving the Venetian blind
oPress top or bottom of cover for longer than one second.
The Venetian blind moves in the desired direction to the end position or stops when the
button is pressed again.
2/7
32524333
J0082524333 13.09.2016
Blinds Management
Centre plate with radio receiver, Centre plate with radio receiver and
sensor connection
Adjusting the slats
oPress top or bottom of cover for shorter than one second.
The slat position changes in the desired direction for as long as the button is pressed.
Operation with radio transmitter
A radio transmitter has to be taught in order to be able to operate the venetian blind via radio.
iObserve the instructions for the radio transmitter.
The slats are adjusted or the Venetian blind is moved depending on how long a radio
transmitter is actuated.
5 Information for electrically skilled persons
5.1 Fitting and electrical connection
DANGER!
Electrical shock when live parts are touched.
Electrical shocks can be fatal.
Before carrying out work on the device or load, disengage all the
corresponding circuit breakers. Cover up live parts in the working environment.
Fitting the device
The Venetian blind control is mounted and connected properly (see instructions for the relevant
Venetian blind control).
oIn the case of covers with sensor connections, install the sensor cable, adjust the
brightness threshold and fasten the sun sensor to a window (see following chapter):
oMount the radio cover with the frame onto the Venetian blind control (figure 1).
oSwitch on mains voltage.
Installing the sensor cable
for covers with sensor connections
iThe sensor cable carries safety extra-low voltage (SELV). Observe fitting instructions
according to VDE 0100.
The sensor cable can be installed in three different ways. In-wall routing (figure 3), surface-
mounted routing (figure 4), and with appropriate covers plugging the sensor cable into the
cover.
iThe sensor cable must not be too long, because otherwise interference from other loads
and cables may occur. This may result in malfunctions. Therefore use only shielded cables,
and connect the shielding to earth. The total length must not exceed 20 m; avoid proximity
to other electrical facilities.
3/7
32524333
J0082524333 13.09.2016
Blinds Management
Centre plate with radio receiver, Centre plate with radio receiver and
sensor connection


Specyfikacje produktu

Marka: JUNG
Kategoria: Niesklasyfikowane
Model: ABAS5232FS

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z JUNG ABAS5232FS, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane JUNG

JUNG

JUNG 531KO5EUM24 Instrukcja

8 Października 2024
JUNG

JUNG 531KO5EUM230 Instrukcja

8 Października 2024
JUNG

JUNG 534KO5EUD2 Instrukcja

8 Października 2024
JUNG

JUNG 531KO6EUM24 Instrukcja

8 Października 2024
JUNG

JUNG IPZ1000REG Instrukcja

7 Października 2024
JUNG

JUNG BTLC1521FS Instrukcja

25 Września 2024
JUNG

JUNG BTME1521FS Instrukcja

25 Września 2024
JUNG

JUNG BTLC1521FSE Instrukcja

25 Września 2024
JUNG

JUNG BTES1521FSE-L Instrukcja

25 Września 2024
JUNG

JUNG BTLS1521FSE Instrukcja

25 Września 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024