Strona 1/10
Centre plate with anti lock-out function, Centre plate with anti lock-out
function and sensor connection
Blinds Management
Centre plate with anti lock-out function
Art. No. : ..5232..
Centre plate with anti lock-out function and sensor connection
Art. No. : ..5232 S..
Operating instructions
1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Danger of electric shock. Always disconnect before carrying out work on the devise or
load. At the same time, take into account all circuit breakers that supply dangerous
voltage to the device or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage.
These instructions are an integral part of the product, and must remain with the end
customer.
2 Device components
Figure 1: Device components
(1) Venetian blind control
(2) Frame
(3) Cover
(4) Status LED
3 Function
Intended use
- Operation of electrically-driven blinds, shutters and awnings
- Operation on control of the Venetian blind control system
Product characteristics
- Status LED
- Lock-out protection
- The individual moving time from the upper end position is storable
1/4
32550723
J:0082550723 16.05.2014
Additional functions for the cover with sensor connection
- Evaluation of a sun sensor
- Brightness threshold adjustable
- Automatic recognition of an outdoor sensor during the first sensor run
Sun protection function for cover with sensor evaluation
The connection of a sun sensor enables automatic shading when it is very bright outside. The
brightness threshold that controls the sun protection can be adjusted on the cover. If the
measured brightness exceeds the predefined brightness threshold for more than 2 minutes, the
Venetian blind moves downwards. The previously stored individual moving time is executed for
an outdoor sensor. The stop position is determined by the sun sensor for an indoor sensor.
i The sun protection function is only activated if the Venetian blind has been moved to the
upper end position and the control has deactivated automatically after 2 minutes. Each
manual operation deactivates the sun protection.
If the brightness threshold is fallen short of for more than 15 minutes, the Venetian blind moves
back to the upper end position.
4 Operation
Moving the Venetian blind
o Press top or bottom of cover for longer than one second.
The Venetian blind moves in the desired direction to the end position or stops when the
button is pressed again.
Adjusting the slats
o Press top or bottom of cover for shorter than one second.
The slat position changes in the desired direction for as long as the button is pressed.
Activating lock-out protection
The lock-out protection prevents the Venetian blind from automatically moving down
unintentionally. Shutting down on site via the sensors or extensions is disabled.
o Press top of cover for longer than 4 seconds.
Status LED is illuminated. Venetian blind moves to the upper end position, the lock-out
protection is activated.
Deactivating lock-out protection
o Press top button briefly.
Status LED goes out.
The lock-out protection is deactivated.
i After a power failure, the lock-out protection is deactivated.
Saving individual moving time
If a Venetian blind should not move to the lower end position "ventilation function" or an outdoor
sensor is used, a shorter moving time can be stored. A time between 0.5 seconds and 2
minutes can be stored.
o Press cover over entire surface for longer than 4 seconds.
The Status LED flashes. The Venetian blind moves automatically to the upper end position.
o Keep the cover pressed in the direction until the Venetian blind is in the desired position.o
o Release cover.
Venetian blind stops.
o Press cover over entire surface for at least 1 second to store the moving time.
- Or -
o Press cover or to discard the moving time.o n
The storage mode is exited automatically and the LED ceases to be illuminated.
2/4
32550723
J:0082550723 16.05.2014
Blinds Management
Centre plate with anti lock-out function, Centre plate with anti lock-out
function and sensor connection
i The individual moving time remains permanently stored. The old moving time will be
replaced if a new moving time is stored.
i To execute the individual moving time, the Venetian blind must be moved to the upper end
position and switch off there automatically after 2 minutes.
5 Information for electrically skilled persons
5.1 Fitting and electrical connection
Mounting and connecting
DANGER!
Electrical shock when live parts are touched.
Electrical shocks can be fatal.
Before carrying out work on the device or load, disengage all the
corresponding circuit breakers. Cover up live parts in the working environment.
The Venetian blind control is mounted and connected properly (see instructions for the relevant
Venetian blind control).
o Install sun sensor for covers with sensor connection and connect to terminal block (see
instructions for the sensors and control).
o Adjust brightness threshold (see following chapter).
i Connect the sun sensor with the correct polarity. If a sensor is connected with reversed
polarity, this will result in malfunctions. It might not be possible to operate the cover any
more.
o Mount cover (3) with frame (2) onto the Venetian blind control (1) (figure 1).
Adjusting brightness threshold for cover with sensor evaluation
Figure 2: Back of cover: Adjuster for brightness threshold
The brightness threshold can be adjusted within a range of approx. 5,000 Lux "small sun" to
approx 80,000 Lux "large sun" using the adjuster (5) on the back of the cover (figure 2). The
adjuster is preset to approx. 15,000 Lux at the factory.
o Adjust the brightness threshold to the required value. Adjust the brightness threshold value
after commissioning if necessary.
3/4
32550723
J:0082550723 16.05.2014
Blinds Management
Centre plate with anti lock-out function, Centre plate with anti lock-out
function and sensor connection


Specyfikacje produktu

Marka: JUNG
Kategoria: Niesklasyfikowane
Model: A5232BFSANM
Kolor produktu: Bia艂y
Typ kontroli: Przyciski
Cz臋stotliwo艣膰 wej艣ciowa AC: 50 Hz
Napi臋cie wej艣ciowe AC: 230 V
Wysoko艣膰 produktu: 620 mm
Szeroko艣膰 produktu: 410 mm
G艂臋boko艣膰 produktu: 305 mm
Poziom ha艂asu: 65 dB
Pr膮d: 2.5 A
Kod zharmonizowanego systemu (HS): 84729080
Pob贸r mocy: 500 W
Zabezpieczenie przed przegrzaniem: Tak
K贸艂ka: Tak
Rozmiary seri A ISO (A0鈥9): A4
Liczba k贸艂: 4 szt.
Bieg wsteczny: Tak
Rozdrabniacz: Rozdrabnianie mikro-ci臋te
Szeroko艣膰 szczeliny wej艣ciowej: 220 mm
Niszczenie p艂yt CD: Nie
Niszczenie papieru: Tak
Niszczenie kart kredytowych: Nie
Poziom ochrony: P-5
Ilo艣膰 arkuszy niszczonych jednocze艣nie: 15 ark.
Wymiary 艣cinek: 2 x 15 mm
Cykl pracy: 30 min
Pr臋dko艣膰 niszczenia: 1500 mm/min
Pojemno艣膰 kosza: 30 l
Gramatura: 80 g/m虏

Potrzebujesz pomocy?

Je艣li potrzebujesz pomocy z JUNG A5232BFSANM, zadaj pytanie poni偶ej, a inni u偶ytkownicy Ci odpowiedz膮




Instrukcje Niesklasyfikowane JUNG

JUNG

JUNG MAGO1193 Instrukcja

10 Grudnia 2024
JUNG

JUNG MAA1193 Instrukcja

10 Grudnia 2024
JUNG

JUNG MACD1193WW Instrukcja

10 Grudnia 2024
JUNG

JUNG WS10D Instrukcja

10 Grudnia 2024
JUNG

JUNG AL1561.07F Instrukcja

10 Grudnia 2024
JUNG

JUNG 1745DSTE Instrukcja

10 Grudnia 2024
JUNG

JUNG MALS1193 Instrukcja

10 Grudnia 2024
JUNG

JUNG ABAS1561.07 Instrukcja

10 Grudnia 2024
JUNG

JUNG LCZ981BF Instrukcja

10 Grudnia 2024
JUNG

JUNG MAAL1193 Instrukcja

10 Grudnia 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane