Instrukcja obsługi JUNG 1730DD

JUNG Opornik 1730DD

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla JUNG 1730DD (6 stron) w kategorii Opornik. Ta instrukcja była pomocna dla 4 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/6
LB management
LB management
LB management
LB managementLB management
Standard rotary dimmer LED
Standard rotary dimmer LED
Standard rotary dimmer LED
Standard rotary dimmer LED
Standard rotary dimmer LEDStandard rotary dimmer LED
Art. no.: 1730DD
Operating instructions
Operating instructions
Operating instructions
Operating instructionsOperating instructions
1
1
1
11 Safety instructions
Safety instructions
Safety instructions
Safety instructionsSafety instructions
Electrical devices may only be mounted and connected by electrically skilled persons.
Electrical devices may only be mounted and connected by electrically skilled persons.
Electrical devices may only be mounted and connected by electrically skilled persons.
Electrical devices may only be mounted and connected by electrically skilled persons.Electrical devices may only be mounted and connected by electrically skilled persons.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Serious injuries, fire or property damage possible. Please read and follow manual fully.Serious injuries, fire or property damage possible. Please read and follow manual fully.
Danger of electric shock. Always disconnect before carrying out work on the devise or load.
Danger of electric shock. Always disconnect before carrying out work on the devise or load.
Danger of electric shock. Always disconnect before carrying out work on the devise or load.
Danger of electric shock. Always disconnect before carrying out work on the devise or load.Danger of electric shock. Always disconnect before carrying out work on the devise or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage. The load
Danger of electric shock. Device is not suitable for disconnection from supply voltage. The load
Danger of electric shock. Device is not suitable for disconnection from supply voltage. The load
Danger of electric shock. Device is not suitable for disconnection from supply voltage. The loadDanger of electric shock. Device is not suitable for disconnection from supply voltage. The load
is not electrically isolated from the mains even when the device is switched off.
is not electrically isolated from the mains even when the device is switched off.
is not electrically isolated from the mains even when the device is switched off.
is not electrically isolated from the mains even when the device is switched off.is not electrically isolated from the mains even when the device is switched off.
Risk of destruction if the set operating mode and load type do not match. Set correct operating
Risk of destruction if the set operating mode and load type do not match. Set correct operating
Risk of destruction if the set operating mode and load type do not match. Set correct operating
Risk of destruction if the set operating mode and load type do not match. Set correct operatingRisk of destruction if the set operating mode and load type do not match. Set correct operating
mode when connecting or exchanging the load.
mode when connecting or exchanging the load.
mode when connecting or exchanging the load.
mode when connecting or exchanging the load.mode when connecting or exchanging the load.
Fire hazard. For operation with inductive transformers, each transformer must be fused on the
Fire hazard. For operation with inductive transformers, each transformer must be fused on the
Fire hazard. For operation with inductive transformers, each transformer must be fused on the
Fire hazard. For operation with inductive transformers, each transformer must be fused on theFire hazard. For operation with inductive transformers, each transformer must be fused on the
primary side in accordance with the manufacturer's instructions. Only safety transformers ac-
primary side in accordance with the manufacturer's instructions. Only safety transformers ac-
primary side in accordance with the manufacturer's instructions. Only safety transformers ac-
primary side in accordance with the manufacturer's instructions. Only safety transformers ac-primary side in accordance with the manufacturer's instructions. Only safety transformers ac-
cording to EN 61558-2-6 may be used.
cording to EN 61558-2-6 may be used.
cording to EN 61558-2-6 may be used.
cording to EN 61558-2-6 may be used.cording to EN 61558-2-6 may be used.
These instructions are an integral part of the product, and must remain with the end customer.
These instructions are an integral part of the product, and must remain with the end customer.
These instructions are an integral part of the product, and must remain with the end customer.
These instructions are an integral part of the product, and must remain with the end customer.These instructions are an integral part of the product, and must remain with the end customer.
2
2
2
22 Intended use
Intended use
Intended use
Intended useIntended use
Switching and dimming of lighting
Mounting in appliance box according to DIN 49073
Operation with suitable cover
3
3
3
33 Product characteristics
Product characteristics
Product characteristics
Product characteristicsProduct characteristics
Product characteristics
Product characteristics
Product characteristics
Product characteristicsProduct characteristics
Device works according to the leading edge phase control or trailing edge phase control
principle
Automatic setting of the dimming principle suitable for the load
Operation without neutral conductor possible
Switch-on via bulb-preserving soft start
Switch on with last saved brightness or saved switch-on brightness
Switch-on brightness can be saved permanently
Minimum brightness can be saved permanently
Electronic short-circuit protection with permanent switch-off after 7 seconds at the latest
Electronic over-temperature protection
Power extension possible by means of power boosters.
1 / 6
82598713 04.12.2018
J0082598713
LB management
LB management
LB management
LB managementLB management
Standard rotary dimmer LED
4
4
4
44 Operation
Operation
Operation
OperationOperation
Switching light or adjusting brightness
Switching light or adjusting brightness
Switching light or adjusting brightness
Switching light or adjusting brightnessSwitching light or adjusting brightness
Figure1: Switching light or adjusting brightness
Press the setting knob briefly: Light switches on or off (Figure 1).
Turn the setting knob quickly: Brightness is changed quickly (Figure 1).
Turn the setting knob slowly: Brightness is changed slowly (Figure 1).
Switching the light on at minimum or maximum brightness
Switching the light on at minimum or maximum brightness
Switching the light on at minimum or maximum brightness
Switching the light on at minimum or maximum brightnessSwitching the light on at minimum or maximum brightness
Figure2: Switching on the light at minimum or maximum brightness
Turn the setting knob by a quarter turn, then press the setting knob briefly: Light switches
on at minimum brightness or maximum brightness (Figure 2).
Save switch-on brightness
Save switch-on brightness
Save switch-on brightness
Save switch-on brightnessSave switch-on brightness
Adjust the brightness.
Press the setting knob for longer than 4 seconds.
Switch-on brightness is saved. The lighting switches briefly off and on again as confirma-
tion.
Delete switch-on brightness
Delete switch-on brightness
Delete switch-on brightness
Delete switch-on brightnessDelete switch-on brightness
Press the setting knob briefly: Light switches on at the saved switch-on brightness.
Press the setting knob for longer than 4 seconds.
The switch-on brightness is deleted. Switching on takes place at the last brightness value
set. For confirmation, the light is switched off briefly and switched on again.
5
5
5
55 Information for electrically skilled persons
Information for electrically skilled persons
Information for electrically skilled persons
Information for electrically skilled personsInformation for electrically skilled persons
5.1
5.1
5.1
5.15.1 Fitting and electrical connection
Fitting and electrical connection
Fitting and electrical connection
Fitting and electrical connectionFitting and electrical connection
DANGER!
Mortal danger of electric shock.
Mortal danger of electric shock.
Mortal danger of electric shock.
Mortal danger of electric shock.Mortal danger of electric shock.
Disconnect the device. Cover up live parts.
Disconnect the device. Cover up live parts.
Disconnect the device. Cover up live parts.
Disconnect the device. Cover up live parts.Disconnect the device. Cover up live parts.
2 / 6
82598713 04.12.2018
J0082598713
LB management
LB management
LB management
LB managementLB management
Standard rotary dimmer LED
Fitting and electrical connection
Fitting and electrical connection
Fitting and electrical connection
Fitting and electrical connectionFitting and electrical connection
Figure3: Connection diagram
Connect 600 Watt LED lamps or compact fluorescent lamps at most per 16ampere circuit
breaker. When connecting transformers, observe the data of the transformer manufac-
turer.
Our dimmers take into account the different electronic characteristics of most LED lamps
found on the market. However, it cannot be guaranteed that in individual cases the de-
sired results may not be achieved.
Operation without neutral conductor possible.
Figure4: Clampable conductor cross-section
Reset the overheating protection / short-circuit protection
Reset the overheating protection / short-circuit protection
Reset the overheating protection / short-circuit protection
Reset the overheating protection / short-circuit protectionReset the overheating protection / short-circuit protection
If the electronic overheating or short-circuit protection has been activated, separate the dimmer
from the grid.
5.2
5.2
5.2
5.25.2 Commissioning
Commissioning
Commissioning
CommissioningCommissioning
Setting the minimum brightness
Setting the minimum brightness
Setting the minimum brightness
Setting the minimum brightnessSetting the minimum brightness
Precondition: The dimmer is ready for operation and the load is switched off.
Press the setting knob for approx. 10 to 15 seconds until the light switches on and off
again.
Press again and hold the knob within 5 seconds. Light switches on at the lowest bright-
ness and slowly becomes brighter.
In the lowest dimming position, a lamp light must be visible.
Once the desired minimum brightness is reached, release the setting knob.
The minimum brightness is stored and the light is switched off.
6
6
6
66 Technical data
Technical data
Technical data
Technical dataTechnical data
Rated voltage AC 230 V~
Mains frequency 50 / 60 Hz
3 / 6
82598713 04.12.2018
J0082598713


Specyfikacje produktu

Marka: JUNG
Kategoria: Opornik
Model: 1730DD

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z JUNG 1730DD, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Opornik JUNG

JUNG

JUNG 1254UDE Instrukcja

13 Września 2024
JUNG

JUNG 1252UDE Instrukcja

3 Września 2024
JUNG

JUNG UD1755REG Instrukcja

30 Sierpnia 2024
JUNG

JUNG UD1255REG Instrukcja

30 Sierpnia 2024
JUNG

JUNG 1271LEDDE Instrukcja

30 Sierpnia 2024
JUNG

JUNG 247.07EB Instrukcja

29 Sierpnia 2024
JUNG

JUNG 1731DD Instrukcja

29 Sierpnia 2024
JUNG

JUNG 1724DM Instrukcja

27 Sierpnia 2024
JUNG

JUNG CD5544.03V Instrukcja

25 Sierpnia 2024
JUNG

JUNG 1724DEB Instrukcja

23 Sierpnia 2024

Instrukcje Opornik

Najnowsze instrukcje dla Opornik

Vimar

Vimar 20175 Instrukcja

15 Grudnia 2024
Vimar

Vimar 19595.0 Instrukcja

15 Grudnia 2024
Vimar

Vimar 16604 Instrukcja

15 Grudnia 2024
Vimar

Vimar 16609 Instrukcja

15 Grudnia 2024
Vimar

Vimar 16625.B Instrukcja

15 Grudnia 2024
Vimar

Vimar 16601.B Instrukcja

15 Grudnia 2024
Vimar

Vimar 16604.B Instrukcja

15 Grudnia 2024
Vimar

Vimar 16602.B Instrukcja

15 Grudnia 2024