Instrukcja obsługi JETI J-ESW4


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla JETI J-ESW4 (4 stron) w kategorii Zabawki sterowane radiem. Ta instrukcja była pomocna dla 7 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/4
USER MANUAL
E 4 XPANDER SW
By JETI model s.r.o. 17. 4. 2015
Návod k obsluze: Switch Expander
-2-
1. Introduction
The Expander SW4 is an extension for magnetic and switches and is designed for switching RC
multiple devices simultaneously. The JETI model company produces a wide range of devices that can
be switched by magnetic switch or RC switch. The Expander SW4 allows you to combine the switching
duties so that several devices can be controlled using one only element. Furthermore, some outputs are
optically isolated to prevent interference. This makes it is possible to isolate control of devices which
may be sensitive to electric interference.
2. Switch Expander circuitry
Expander SW4 has on output for a magnetic or RC switch and 4 outputs, 3 of them are optically
isolated (OPTO1-OPTO3). The output that is not optically isolated is connected to the magnetic or RC
switch directly, including the power supply (Master input). The optically isolated outputs must be
powered separately. One of the optically isolated outputs is inverted (e.g. for SBEC40) OPT INV.
Návod k obsluze: Switch Expander
-3-
Fig. 1: Expander SW4 application connection
Circuitry with the RC Switch in case its setting has been changed in the transmitter, it is necessary
to make sure that the switch is set to normal output (as by default). If the output is set to inverted, the
Expander SW4 would not work correctly. The RC switch is connected to the pander SW4 output Ex
labelled Switch, see Fig. 1.
Circuitry with the magnetic switch normal output of the magnetic switch is connected to the input
of the Expander SW4 (labelled Switch), see Fig. 1.
If optical connection is needed, the poles of the separated circuits must not be connected an
anywhere, as well as the +poles.
Magnetic or RC switches, as well as the Expander SW4, are supplied power from the same Master
output. Thus it is necessary to have the power supply connected at least to this connector, see Fig. 1.
If the power supply of the Expander SW4 is interrupted when the magnetic or RC switch is on,
the devices connected to any optically isolated output are switched OFF!! If only a magnetic or
RC switch is disconnected from the Expander SW4, all the devices connected to Expander SW4
outputs remain switched . ON
Please follow all the directives described in individual manuals for the magnetic or RC switch!


Specyfikacje produktu

Marka: JETI
Kategoria: Zabawki sterowane radiem
Model: J-ESW4

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z JETI J-ESW4, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Zabawki sterowane radiem JETI

JETI

JETI TD1609S Instrukcja

23 Września 2024
JETI

JETI JDEX-RR7 Instrukcja

23 Września 2024
JETI

JETI JEX-MF2G-800 Instrukcja

22 Września 2024
JETI

JETI JM-090-L Instrukcja

22 Września 2024
JETI

JETI TD0905L Instrukcja

22 Września 2024
JETI

JETI AddCAP 1640 Instrukcja

22 Września 2024

Instrukcje Zabawki sterowane radiem

Najnowsze instrukcje dla Zabawki sterowane radiem