Installation instructions
Compact speed monitor
DIA
701092 / 03 09 / 2007
UK
UK
UK
UK
UK
2
1 Functions and features
The Compact speed monitor detects without contact whether a minimum speed is
reached and signals underspeed by means of a switching signal.
Nominal sensing range (Sn) 10 mm; Preset speed adjustable, see type label.
2 Installation
E
A
BC
D
F
A
B
C
³F
³2 x A
½ x Sn
D
E
Fix the unit by means of a mounting device and secure it by means of the nuts
provided so that it cannot work loose. Flush installation.
Adhere to the above dimensions to ensure a correct function.
3 Electrical connection
Disconnect power.
Connect the unit according to the indications on the type label.
Note: insert a miniature fuse according to the technical data sheet, if specified.
Recommendation: check the safe functioning of the unit after a short circuit.
3
UK
4 Adjustment
1
2
LEDs
Green LED: output switched (actual
speed > preset speed)
Yellow LED (optional for 2-wire AC/DC):
sensor damped
multiturn potentiometer
preset value
1.
2.
Keep the speed to be monitored in the plant on a constant level.
The yellow LED must flash (damping pulses are detected).
Start the adjustment according to A or B when the start-up delay* (AÜ see type
label) has elapsed.
A
Green LED lit
B
Green LED not lit
Turn the pot clockwise until the LED goes
off.
Turn the pot slowly anticlockwise until the
LED is lit.
Turn the pot slowly anticlockwise until the
LED is let.
On delivery: pot at the right end stop (except DI5011 = approx. 30 pulses/min).
5 Operation
The operation is maintenance-free. Ensure the following for a correct function:
Keep the sensing face and the open space free of metal deposits and foreign
bodies.
Do not operate units with high field intensity (e.g. walkie-talkies) at close range
to the speed monitor.
*) The start-up delay (AÜ) suppresses an error signal as long as the machine is in
the process of starting and has not yet reached its nominal speed. After applica-
tion of the operating voltage the start-up delay is active only once.
If the drive is often turned on and off, couple the supply voltage of the drive and
the monitor. By doing so, the start-up delay is active every time the drive is turned
on.


Specyfikacje produktu

Marka: IFM
Kategoria: nieskategoryzowany
Model: DI004A

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z IFM DI004A, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje nieskategoryzowany IFM

IFM

IFM RV6068 Instrukcja

4 Września 2024
IFM

IFM NN5010 Instrukcja

4 Września 2024
IFM

IFM PL1502 Instrukcja

4 Września 2024
IFM

IFM OB5025 Instrukcja

4 Września 2024
IFM

IFM PL1512 Instrukcja

4 Września 2024
IFM

IFM RB6026 Instrukcja

4 Września 2024
IFM

IFM RV6106 Instrukcja

3 Września 2024
IFM

IFM RC6045 Instrukcja

3 Września 2024
IFM

IFM RU6067 Instrukcja

3 Września 2024
IFM

IFM EVC995 Instrukcja

3 Września 2024

Instrukcje nieskategoryzowany

Najnowsze instrukcje dla nieskategoryzowany

Meec Tools

Meec Tools 010-084 Instrukcja

6 Października 2024
Outwell

Outwell Scenic Road 250 Instrukcja

5 Października 2024
Impact

Impact QuikBalance Instrukcja

4 Października 2024
Impact

Impact CA-112 Instrukcja

4 Października 2024
Impact

Impact LS-BHA Instrukcja

4 Października 2024
Impact

Impact LKB-5C Instrukcja

4 Października 2024
Impact

Impact RST-001 Instrukcja

4 Października 2024