80293944 / 00 04 / 2020
Operating Instructions
IO-Link Master with AS-
Interface Interface
StandardLine
4 Ports
IP 65 / IP 66 / IP 67
AC6000
Firmware: 2.4.x or higher
English
IO-Link Master with AS Interface Interface StandardLine 4 Po- rts IP 65 / IP 66 / IP 67
2
Contens
1 4 Preliminary note
1.1 Legal and copyright information ........................................................................................... 4
1.2 Symbols used ....................................................................................................................... 5
1.3 Warnings used ..................................................................................................................... 5
1.4 User documentation for this device...................................................................................... 6
1.5 Modification history .............................................................................................................. 6
2 Safety instructions 7
2.1 General 7................................................................................................................................
3 8 Functions and features
4 9 Function
4.1 Link IO- .................................................................................................................................. 9
4.1.1 IO -Link supply .............................................................................................................................. 9
4.2 interface AS- ......................................................................................................................... 9
4.3 Parameter setting ................................................................................................................. 9
4.4 Visual indication .................................................................................................................10
5 Mounting 11
5.1 Mounting the device ...........................................................................................................11
6 Electrical connection 12
6.1 Notes ..................................................................................................................................12
6.2 IO-Link ports .......................................................................................................................13
6.2.1 Connecting IO Link devices for Class A operation- ..................................................................... 13
6.2.2 Connecting IO Link devices for Class B operation- ..................................................................... 14
6.3 Connecting the unit ............................................................................................................15
7 Operating and display elements 16
7.1 Overview ............................................................................................................................16
7.2 LED indicators ....................................................................................................................17
7.2.1 Status LEDs ............................................................................................................................... 17
7.2.2 Voltage supply ............................................................................................................................ 17
7.2.3 IO -Link ports (Class A) ............................................................................................................... 18
8 - Set up 19
9 Configuration 20
9.1 Notes ..................................................................................................................................21
9.1.1 Device structure ......................................................................................................................... 21
9.1.2 Options for parameter setting ..................................................................................................... 21
9.1.3 Using the command interface ..................................................................................................... 22
9.2 Addressing the AS i slave of the AC6000- ..........................................................................24
9.2.1 Addressing via AS- i master ........................................................................................................ 24
9.2.2 Addressing with addressing unit ................................................................................................. 25
IO-Link Master with AS Interface Interface StandardLine 4 Ports IP 65 / IP 66 / IP 67-
3
9.3 Adjusting the gateway profile .............................................................................................26
9.3.1 Example: Setting the gateway profile ......................................................................................... 27
9.4 Configuring IO-Link ports ...................................................................................................28
9.4.1 Note: Device validation and data storage ................................................................................... 28
9.5 Reading / writing parameters of the IO Link devices- .........................................................29
9.5.1 Example: Reading parameter ..................................................................................................... 29
9.5.2 Example: Writing parameter ....................................................................................................... 31
9.6 Reading / writing process data ...........................................................................................33
9.7 Reading identification and diagnostic information .............................................................33
9.8 33 Reading IO Link events- .....................................................................................................
9.9 Resetting IO-Link master ...................................................................................................33
9.10 Updating the firmware ........................................................................................................34
10 Maintenance, repair and disposal 35
10.1 Cleaning process ...............................................................................................................35
10.2 Replacing IO Link device- ...................................................................................................35
11 36 Factory settings
12 Accessories 37
13 38 Appendix
13.1 Technical data ....................................................................................................................39
13.1.1 Application .................................................................................................................................. 39
13.1.2 Electrical data ............................................................................................................................. 39
13.1.3 Inputs / outputs ........................................................................................................................... 39
13.1.4 Inputs .......................................................................................................................................... 40
13.1.5 Outputs ....................................................................................................................................... 40
13.1.6 Interfaces .................................................................................................................................... 40
13.1.7 Operating conditions .................................................................................................................. 41
13.1.8 Approvals / Tests ........................................................................................................................ 41
13.1.9 AS-i classification ....................................................................................................................... 41
13.1.10 Mechanical data ......................................................................................................................... 41
13.1.11 Electrical connection .................................................................................................................. 42
13.2 Interface AS- .......................................................................................................................43
13.2.1 Mapping: inputs and outputs of the IO Link ports- ....................................................................... 44
13.3 Command interface ............................................................................................................61
13.3.1 Structure of the command interface ...........................................................................................61
13.3.2 Overview: Acyclic commands ..................................................................................................... 64
13.3.3 0x01: Read IO Link Port Configuration Errors- ............................................................................ 65
13.3.4 0x02: Write IO-Link Port Configuration ....................................................................................... 66
13.3.5 0x03: Read IO Link Port Configuration- ....................................................................................... 70
13.3.6 0x04: Read Input Process Data .................................................................................................. 73
13.3.7 0x05: Read Output Process Data ............................................................................................... 75
13.3.8 0x06: Write Output Process Data ............................................................................................... 77
13.3.9 0x07: Read Diagnosis Data ........................................................................................................ 79
13.3.10 0x08: Factory Defaults................................................................................................................ 81
13.3.11 0x09: Set IO Link Failsafe Data- .................................................................................................. 82
13.3.12 0x0A: Write Parameter ............................................................................................................... 84
13.3.13 0x0B: Read Parameter ............................................................................................................... 87
13.3.14 0x0C: Read Device Name, Serial Number, HW and SW Revisions ........................................... 89
13.3.15 0x0D: Update Firmware.............................................................................................................. 91
14 93 Index


Specyfikacje produktu

Marka: IFM
Kategoria: nieskategoryzowany
Model: AC6000

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z IFM AC6000, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje nieskategoryzowany IFM

IFM

IFM RV6068 Instrukcja

4 Września 2024
IFM

IFM NN5010 Instrukcja

4 Września 2024
IFM

IFM PL1502 Instrukcja

4 Września 2024
IFM

IFM OB5025 Instrukcja

4 Września 2024
IFM

IFM PL1512 Instrukcja

4 Września 2024
IFM

IFM RB6026 Instrukcja

4 Września 2024
IFM

IFM RV6106 Instrukcja

3 Września 2024
IFM

IFM RC6045 Instrukcja

3 Września 2024
IFM

IFM RU6067 Instrukcja

3 Września 2024
IFM

IFM EVC995 Instrukcja

3 Września 2024

Instrukcje nieskategoryzowany

Najnowsze instrukcje dla nieskategoryzowany

Asko

Asko DBI644MIB.S.TW/1 Instrukcja

28 Października 2024
Asko

Asko DFS233IB.S.TW/1 Instrukcja

28 Października 2024
Emko

Emko EZM-9920 Instrukcja

27 Października 2024
Emko

Emko ESM-3712-H Instrukcja

27 Października 2024
Emko

Emko ATS-10 Instrukcja

27 Października 2024
Emko

Emko EAOM-11.2 Instrukcja

27 Października 2024
Emko

Emko EPM-3790 Instrukcja

27 Października 2024
Emko

Emko EPM-7790 Instrukcja

27 Października 2024
Livarno Lux

Livarno Lux IAN 108340 Instrukcja

27 Października 2024
Livarno Lux

Livarno Lux HG06009A-BS Instrukcja

27 Października 2024