Instrukcja obsługi Hunter Dempsey 59243

Hunter Wentylator Dempsey 59243

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Hunter Dempsey 59243 (11 stron) w kategorii Wentylator. Ta instrukcja była pomocna dla 6 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/11
Installation Manual
©2019 Hunter Fan Co.
Model: 50282 Brushed Nickel
59243 Brushed Nickel
59244 Fresh White
59445 Noble Bronze
Fan weight ±2 lbs: 18.3 lbs (8.3 kg)
Dempsey
PG3773 r042519
Ladder
9/64” Drill BitDrill
Screwdriver
Pliers Wire Strippers
OPTIONAL
If mounting to a support structure, you will also need these tools.
1
The ceiling fan you purchased will provide comfort and performance in your home or ofce for many years. This instruction manual contains
complete instructions for installing and operating your fan. We are proud of our work and appreciate the opportunity to supply you with the
best ceiling fan available anywhere in the world.
We are here to help!
This Instruction Manual is designed to make installation as simple as possible. While working through this Instruction Manual, keep
your smartphone or tablet nearby. We have added video links to help you through the more technical sections. If you are unfamiliar or
uncomfortable with wiring, contact a qualied electrician. We also provide telephone support at 1.888.830.1326 or visit us
at HunterFan.com.
WARNING
READ and SAVE These Instructions
Warning
w.1 - To reduce the risk of re, electrical shock, or personal injury, mount fan directly from building structure and/or an outlet box marked acceptable for fan support of 70 lbs (31.8 kg) and use the
mounting screws provided with the outlet box.
w.2 - To avoid possible electrical shock, before installing or servicing your fan, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you
cannot lock the circuit breakers in the off position, securely fasten a prominent warning device, such as a tag, to the service panel.
w.3To reduce the risk of electric shock, this fan must be installed with an isolating wall control/switch.
w.4 - To reduce the risk of personal injury, do not bend the blade brackets when installing the blade brackets, balancing the blades, or cleaning the fan. Do not insert foreign objects in between
rotating fan blades.
w.5 - Chemical burn hazard. Keep batteries away from children. This remote contains a lithium button cell battery. If a new or used lithium button/coin cell battery is swallowed or enters the body,
it can cause severe internal burns and can lead to death in as little as 2 hours. Always completely secure the battery compartment. If the battery compartment does not close securely, stop using
the product, remove the batteries, and keep it away from children. If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention.
Dispose of cells properly and keep away from children. Even used cells may cause injury.
Caution
c.1 - All wiring must be in accordance with national and local electrical codes ANSI/NFPA 70. If you are unfamiliar with wiring, use a qualied electrician.
c.2 - Use only Hunter replacement parts.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions
may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Caution: modications not approved by the party responsible for compliance could void user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
This product conforms to UL Standard 507.
2
Do not discard the hardware bags or mix parts from
different bags. Make note of the symbol printed on
each hardware bag. The symbols can be used to
identify the appropriate hardware for each step.
We recommend that you pull everything out of the box and lay it out. We have
grouped the drawn components below with the hardware you’ll need for those
parts. The screws below are drawn to scale to make it easier to identify what
piece of hardware is needed to install each component.
x4
x2
x2 x3
x3
x1
For installing the hanger bracket and wiring the fan
For installing the blades
For installing the canopy
For installing the light kit
Motor
Canopy
Canopy
Screw
Top Housing
Screw
Grounding
Screw
Ceiling Bracket
Canopy Trim Ring
Wood Screw
Wire Nut
Washer
bag
Hunter Pro Tip:
Find a part that is missing or damaged?
Don’t take it back to the store. Let us make it right. Visit us at HunterFan.com or call us at 1.888.830.1326.
bag
M0230-01 r042519
Spare Parts
For your convenience,
you may receive extra fasteners.
bag
Remote Components
Remote Control
Remote Receiver
Remote Cradle
Upper Motor Housing
x12 x12
Blade ScrewBlade Washer
bag bag
x4
Blade
Glass
Upper Switch Housing
Light Kit Assembly
x6Light Kit Screw
bagx2


Specyfikacje produktu

Marka: Hunter
Kategoria: Wentylator
Model: Dempsey 59243

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Hunter Dempsey 59243, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Wentylator Hunter

Hunter

Hunter Grove Park 50341 Instrukcja

8 Października 2024
Hunter

Hunter Charlotte 50402 Instrukcja

8 Października 2024
Hunter

Hunter Claudette 59622 Instrukcja

8 Października 2024
Hunter

Hunter Havoc 59470 Instrukcja

8 Października 2024
Hunter

Hunter Starklake 50409 Instrukcja

8 Października 2024
Hunter

Hunter Midtown 54211 Instrukcja

8 Października 2024
Hunter

Hunter Donegan 53336 Instrukcja

8 Października 2024
Hunter

Hunter 53328 Instrukcja

8 Października 2024
Hunter

Hunter Anslee 59266 Instrukcja

8 Października 2024

Instrukcje Wentylator

Najnowsze instrukcje dla Wentylator

Air King

Air King E130SH Instrukcja

10 Października 2024
TriStar

TriStar VE-5936 Instrukcja

10 Października 2024
Orbegozo

Orbegozo PW 1321 Instrukcja

10 Października 2024
Thermex

Thermex Silent 100 CZ Instrukcja

9 Października 2024
Imarflex

Imarflex IF-375BU Instrukcja

9 Października 2024
Imarflex

Imarflex IF-365BK Instrukcja

9 Października 2024
Kogan

Kogan KARCDCFANLA Instrukcja

9 Października 2024
Westinghouse

Westinghouse 72206 Instrukcja

9 Października 2024
Westinghouse

Westinghouse 78425 Instrukcja

9 Października 2024