Instrukcja obsługi Hotpoint HW18HN2DAA

Hotpoint klimatyzacja HW18HN2DAA

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Hotpoint HW18HN2DAA (50 stron) w kategorii klimatyzacja. Ta instrukcja była pomocna dla 2 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/50
READ CAREFULLY.
KEEP THESE INSTRUCTIONS.
Ductless Single Zone
with Highwall Indoor Unit
Installation
Instructions
Design may vary by model number L’aspect peut varier selon le numéro
de modèle.
El diseño puede variar según el
número de model.
31-5000884 Rev. 3 04-24
231-5000884 Rev. 3
READ AND SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE
SAFETY INFORMATION
WARNING For your safety; the information in this manual must be followed to minimize the risk of
re, electric shock, or personal injury.
Use this equipment only for its intended purpose as
described in this manual.
This heat pump must be properly installed in
accordance with these instructions before it is used.
All wiring should be rated for the amperage value
listed on the rating plate. Use only copper wiring.
All electrical work must be completed by a qualified
electrician and completed in accordance with local
and national building codes.
All air conditioners contain refrigerants, which under
federal and/or local law must be removed prior to
product disposal. If you are getting rid of an old
product with refrigerants, check with the company
handling disposal..
These R32 heat pumps systems require that
contractors and technicians use tools, equipment and
safety standards approved for use with this refrigerant.
DO NOT use equipment certified for R22 or R410A
refrigerant only.
WARNING RISK OF ELECTRIC SHOCK. Could cause injury or death.
An adequate ground is essential before connecting
the power supply or charging with refrigerant.
Disconnect all connected electric power supplies
before servicing.
Aluminum building wiring may present special
problems - consult a qualified electrician.
The surrounding conditions (ambient temperature,
direct sunlight, and rainwater) shall be noticed during
electrical wiring, with effective protective measures
being taken.
The dedicated branch circuit must be used, and
leakage protector with sufficient capacity must be
installed.
Repair or replace immediately all electrical wiring that
has become frayed or otherwise damaged. Do not use
wiring that shows cracks or abrasion damage along its
length or at either end.
When the unit is in the STOP position, there is still
voltage to the electrical controls.
Copper wire cable in line with local standards shall be
used as the power line and connector wire.
Both the indoor unit and outdoor unit shall be reliably
earthed.
Wiring for the outdoor unit shall be made first and
then the indoor unit. The air conditioner can only be
powered on after wiring and pipe connection.
WARNING RISK OF FIRE. Could cause injury or death.
Do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or
any other appliance.
ATTENTION
Please do not use extension cords in this system.
Aluminum building wiring may have special problems, please consult a licensed electrician.
For any service which requires entry into the
refrigerant sealed system, Federal regulations require
that the work is performed by a technician having a
Class II or Universal certication.
31-5000884 Rev. 3 3
READ AND SAVE THESE INSTRUCTIONS
WARNING
- This product is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the product.
- Ensure that the unit shall be installed in accordance with local and national wiring codes.
- For the dimensions of the space necessary for correct installation of the appliance, including the minimum
permissible distances to adjacent structures, refer to this document.
- Ensure only approved units are connected together and that all refrigerant line dimensions and refrigerant
charging requirements are followed to prevent exceeding the maximum operating pressure.
- ONLY connect units that are labeled with the same refrigerant.
- Any damage of electrical supply must be replaced by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
- Means for disconnection must be incorporated in the fixed wiring in accordance with wiring rules. Disconnect
ampere rating must be at least 115% of the Minimum Circuit Ampacity listed on the rating plate for this product.
Disconnect must be installed within sight and readily accessible. Refer to local and national electric code for any
additional requirements specified in your region of install.
Safety Awareness
1. Procedures: operation shall be made as per controlled procedures to minimize the probability of risks.
2. Area: area shall be divided and isolated appropriately, and operation in an enclosed space shall be avoided.
Before the refrigeration system is started or before hot working, ventilation or opening of the area shall be
guaranteed.
3. Site inspection: the refrigerant shall be checked.
4. Fire control: the fire extinguisher shall be placed nearby, and fire source or high temperature is not allowed; the
sign of “No smoking” shall be arranged.
SAFETY INFORMATION
IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE
For more help, visit HotPoint.com or call the consumer help line at 800.432.2737
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT Save these instructions for local inspector’s use.
IMPORTANT Observe all governing codes and ordinances.
Note to installer – Be sure to leave these instructions with the Consumer.
Note to consumer Keep these instructions for future reference.
Skill level A licensed certified technician (to handle refrigerant R32, recovery, etc) and a qualified electrician
are required for installation and service of this split heat pump system.
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not covered under the limited warranty.
For personal safety, this system must be properly grounded.
Protective devices (fuses or circuit breakers) acceptable for installation are specified on the nameplate of
each unit.
Make sure to minimize wiring or plumbing inside the wall when installing.


Specyfikacje produktu

Marka: Hotpoint
Kategoria: klimatyzacja
Model: HW18HN2DAA

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Hotpoint HW18HN2DAA, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje klimatyzacja Hotpoint

Hotpoint

Hotpoint AHHS09D3XXA Instrukcja

9 Października 2024
Hotpoint

Hotpoint AHES12D3XXA Instrukcja

9 Października 2024
Hotpoint

Hotpoint AHES09D3XXA Instrukcja

9 Października 2024
Hotpoint

Hotpoint AHES07D3XXA Instrukcja

9 Października 2024
Hotpoint

Hotpoint AHHS07D2XXA Instrukcja

8 Października 2024
Hotpoint

Hotpoint AHHS15D3XXA Instrukcja

8 Października 2024
Hotpoint

Hotpoint AHHS12D3XXA Instrukcja

8 Października 2024
Hotpoint

Hotpoint AHES15D3XXA Instrukcja

8 Października 2024
Hotpoint

Hotpoint AHHS12E3XXA Instrukcja

8 Października 2024
Hotpoint

Hotpoint AHHS09E3XXA Instrukcja

8 Października 2024

Instrukcje klimatyzacja

Najnowsze instrukcje dla klimatyzacja

LG

LG HS-H076QPA0 Instrukcja

15 Października 2024
Klarstein

Klarstein Vita Pure 2G Instrukcja

15 Października 2024
Gree

Gree ETAC-15HP265V20B Instrukcja

15 Października 2024
Qlima

Qlima P 126 Instrukcja

14 Października 2024
Mitsubishi

Mitsubishi MSZ-CB22VA Instrukcja

14 Października 2024
Suntec

Suntec Motion 90+ Instrukcja

14 Października 2024
Danby

Danby DTAC120B1WDB Instrukcja

14 Października 2024
Amana

Amana PTC093K35AXXX Instrukcja

14 Października 2024
Amana

Amana AMAP121AB-2 Instrukcja

14 Października 2024