Instrukcja obsługi Honeywell TrueZONE HZ322

Honeywell Niesklasyfikowane TrueZONE HZ322

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Honeywell TrueZONE HZ322 (12 stron) w kategorii Niesklasyfikowane. Ta instrukcja była pomocna dla 12 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/12
HZ322 TrueZONE®
Zone Panel Professional Installation Guide
69-2199-03
Installation Guide
Specifications ..................................................................................................................................
1
Accessories .....................................................................................................................................
1
Mounting ..........................................................................................................................................
2
Wiring ..............................................................................................................................................
3
Heat Pump ......................................................................................................................................
6
Basic Configuration .........................................................................................................................
7
Advanced Configuration ..................................................................................................................
8
Operation .........................................................................................................................................
9
Checkout .........................................................................................................................................
9
Warranty ........................................................................................................................................
10
SPECIFICATIONS
TABLE OF CONTENTS
Input Ratings:
Voltage: 18-30 VAC 50/60 Hz transformer of 40 VA
or more.
Current Draw:
Zone Panel: 7.5 VA max.
THM4000R Wireless Adapter: 2 VA max.
All VA specifications at 24 VAC.
Wiring:
18- or 20-gauge solid (not stranded) wire.
Humidity Ratings:
5% to 90% RH non-condensing.
Temperature Ratings:
Shipping: -20° to 150°F (-29° to 66°C)
Operating: -40° to 165°F (-4to 74°C)
Dimensions:
See below.
Emissions:
Complies with FCC Class B, part 15 requirements.
Read and save these instructions.
Need Help?
For assistance with this product please visit http://customer.honeywell.com
and/or call Honeywell Zoning Hotline toll-free at 1-800-828-8367
® U.S. Registered Trademark. US Patent No. 7,693,591; 7,904,830; 7,913,180; 7,904,830; 7,819,331; 7,766,246; 7,558,648 and other patents pending.
Copyright © 2012 Honeywell International Inc. All rights reserved.
Fig. 1. HZ322 TrueZONE panel dimensions in in.
(mm).
M28011
1.86 (47)
8 (203)
11.5
(292)
HZ322 TrueZONE
1 69-2199—03
APPLICATION
ACCESSORIES
Table 1. Recommended Thermostats.
System Non-Programmable Programmable
Single-
Stage
TH5110D, TH3110D,
T87N
TH8110U, TH6110D,
TH4110D
Multi-
Stage
TH5220D TH8320U, TH8321U,
TH6220D, YTH9421C
Heat-
Pump
TH5220D
TH3210D
TH8320U
TH8321U
TH6220D
TH4210D
YTH9421C
Wire-
less*
TH5320R TH6320R
Note: All versions of the model numbers listed above
will work with the applications they're listed for.
* For RedLINK™ wireless devices, a THM4000 is
required.
Table 2. Recommended Dampers.
Type Honeywell
Damper
Round Rectangular
Zone Spring-open/
power-closed
ARD
(6VA)
ZD (6 VA)
Power-open/
power-closed
MARD/
RRD
(2 VA)
For recommended
dampers call the
Honeywell Zoning
Hotline at
1-800-828-8367.
Bypass -Static pres
sure regulating
damper
SPRD/
MARD
(2 VA)
SPRD
Table 3. Recommended Commercial Dampers.*
Type Actuation Round Rectangular
Zone Power-open/
power-closed
MARD D2 or D3 with
ML6161A2009*
Bypass Power-open/
power-closed
MARD
with SPC
D3 with
ML6161B2024*
and SPC
* Or equivalent damper and actuator.
Table 4. Accessories.
Accessory Description
40 VA transformer* AT140A1042*
75 VA transformer AT175A1008
Discharge Air Temperature
Sensor *
DATS C7735A1000*
SDCR** Slave Damper Control
Relay
Wireless Adapter*** THM4000R1000
Wireless Outdoor Air
Temperature Sensor***
C7089R1013
Portable Comfort Control*** REM5000R1001
RedLINK Internet
Gateway***
THM6000R1002
* Included in HZ322K kit.
** Use an SDCR (Slave Damper Control Relay) to
add additional dampers to a zone to surpass the
maximum Damper VA rating per Zone.
*** For RedLINK™ wireless devices, a THM4000 is
required.
The HZ322 TrueZONE® panel controls:
• Conventional gas, oil, or electric forced-air systems up to 2 stages heat and cool;
• Heat pump systems with single stage compressor and auxiliary heat, and two stage heat pumps with no auxiliary heat;
and two stage heat pumps with no auxiliary heat;
• 2 or 3 forced-air zones with wired thermostats, or wireless thermostats using THM4000R wireless adapter.
Please refer to TrueZONE Panel Frequently Asked Questions form 50-9694 for operating details.
http://customer.honeywell.com


Specyfikacje produktu

Marka: Honeywell
Kategoria: Niesklasyfikowane
Model: TrueZONE HZ322

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Honeywell TrueZONE HZ322, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Honeywell

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane