Instrukcja obsługi Honeywell HWM845B
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Honeywell HWM845B (17 stron) w kategorii Nawilżacz. Ta instrukcja była pomocna dla 9 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/17
GETTING TO KNOW YOUR
HUMIDIFIER
Visible Warm Mist
• With warm mist humidification, water is
boiled in a heating chamber and is then
released into the air as warm mist.
• Because the water is boiled, it produces
99.5% bacteria free mist.1
• Be careful not to over-humidify; if
condensation forms around the unit
or on walls and surfaces, turn the
humidifier off or to a lower setting.
Instruction Manual
WARM MIST HUMIDIFIER
HWM845 series
Humidity Level
• The ideal indoor humidity level is 4060%
• Use a Honeywell humidity monitor
(HHM10 or H10C) to check your indoor
humidity level (not included)
For questions and information about this humidifier
Visit or Callwww.HoneywellPluggedIn.com 800-477-0457
2
1. ALWAYSThe humidifier should be placed on
a firm, flat, waterproof surface at least four
feet (1.2m) away from bedside, 12 inches
(30cm) from the wall and out of reach of
children and pets.
2. Be sure the humidifier is in a stable position
and the power cord is away from heated
surfaces and out of the way to prevent the
humidifier from being overturned.
3. The humidifier should not be left unattended,
especially in a closed room since air could
become saturated and leave condensation
on walls and furniture. If room becomes
saturated, open the door and turn the
humidifier off or down.
4. Before using the humidifier, extend the
cord and inspect for any signs of damage.
DO NOT use the unit if the cord has been
damaged. DO NOT operate with power cord
coiled or with twist tie in place.
5. The humidifier has a polarized plug (one
blade is wider than the other) as a safety
feature. This plug will fit into a polarized
outlet only one way. If the plug does not fit
fully into the outlet, reverse the plug. If it still
does not fit, contact a qualified electrician.
DO NOT attempt to defeat this safety
feature.
6. CAUTION: To avoid fire or electric shock
hazard, plug the humidifier directly into a
120V AC electrical outlet. To avoid risk of
fire, electric shock, or personal injury, DO
NOT use an extension cord or power strip.
7. ALWAYSThe humidifier should be
unplugged and emptied when not in
operation or while being cleaned. Shut off
and unplug humidifier before moving.
DO NOT move or tilt humidifier while it is
in operation. Plug and unplug unit with dry
hands. NEVER pull by cord.
8. DO NOT operate the humidifier without
water. Turn off and unplug unit when tank
is empty and the reset light is on.
9. Humidifier requires regular cleaning.
Refer to and follow cleaning instructions.
10. DO NOT operate outdoors; this humidifier
is intended for indoor residential use only.
11. DO NOT cover or insert objects into any
openings on the unit. block intake DO NOT
or output vents.
12. DO NOT attempt to repair or adjust any
electrical or mechanical functions on this
humidifier. Doing so will void your warranty.
13. DO NOT add any essential oils or
medications (e.g. Kaz Inhalant or Vicks
VapoSteam®) into Chimney, Reservoir,
or Water Tank.
14. DO NOT touch the steam vapor. Steam
can cause burns. operate without DO NOT
the Essential Oil Cup in place on top of
the Mist Chimney.
15. For Residential Use Only
SAVE THESE INSTRUCTIONS.
IMPORTANT
SAFETY INSTRUCTIONS
READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE
USING THIS HUMIDIFIER
When using electrical appliances, basic precautions should always be followed to reduce the risk
of fire, electric shock, and injury to persons, including the following:
¹ Based on Intertek Testing Services NA, Inc. Independent Laboratory Testing
Report 103340980COL-001. Results are based on the reduction of the
following organisms after 1 hour of continuous use:
Bacteria: E. coli up to 99.999% after 1 hour of continuous use
Fungus: P. citrinum up to 99.999% after 1 hour of continuous use
Mold: A. niger up to 99.999% after 1 hour of continuous use
Virus: Phi-X174 up to 99.999% after 1 hour of continuous use
4
SETTING UP YOUR HUMIDIFIER
1. Remove packaging materials. Keep this Instruction Manual for reference.
2. Remove twist tie from power cord and extend power cord full length.
3. Ensure Proper Assembly. Make sure Mist Chimney, Essential Oil Cup, and Water
Tray are securely in place and that Heating Element Cover is secured. See
Reassembling instructions after section for reference.Cleaning your Humidifier
4. Place humidifier on a firm, level, water resistant surface a minimum of 12 inches
(30 cm) from walls. Steam should be directed away from any walls, bedding, and furniture.
WARNING : KEEP OUT OF REACH OF CHILDREN. THIS PRODUCT PRODUCES HOT STEAM AND
SHOULD BE PLACED IN AN AREA NOT ACCESSIBLE TO CHILDREN OR PETS, WITH THE POWER CORD
OUT OF REACH.
FILLING / REFILLING
NOTE: Tank should be carried using two hands; one hand on the Tank Handle and the other supporting the
bottom of the Tank.
Manufacturer will not accept responsibility for property damage caused by water spillage.
1. Remove Tank by grasping Handle and pulling up. Remove Tank Cap by turning counter clockwise (to the left).
2. Fill Water Tank with cool water. fill with warm or hot water. DO NOT
DO NOT ADD ESSENTIAL OILS, MEDICATIONS, OR INHALANT LIQUIDS to the Water Tank. Doing so could
cause damage to the humidifier and void the warranty.
3. Replace Tank Cap by turning clockwise (to right) to screw back in place. over-tighten. Place Water DO NOT
Tank back on humidifier Base.
RESETTING YOUR HUMIDIFIER
When your humidifier is out of water, the Reset Light ( ) will illuminate. To reset:
1. ) Turn power OFF (
2. Refill and replace Tank
3. ) Wait 5 minutes and turn power ON (
NOTE: If Reset Light ( ) is still on, clean the Heating Element
( section) see Cleaning Instructions
4
3
2
1
Specyfikacje produktu
Marka: | Honeywell |
Kategoria: | Nawilżacz |
Model: | HWM845B |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Honeywell HWM845B, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Nawilżacz Honeywell
28 Września 2024
28 Września 2024
28 Września 2024
28 Września 2024
28 Września 2024
28 Września 2024
28 Września 2024
28 Września 2024
28 Września 2024
28 Września 2024
Instrukcje Nawilżacz
- Nawilżacz Samsung
- Nawilżacz DeLonghi
- Nawilżacz Beurer
- Nawilżacz Xiaomi
- Nawilżacz LERAN
- Nawilżacz Sharp
- Nawilżacz Tefal
- Nawilżacz TP-Link
- Nawilżacz Philips
- Nawilżacz SilverCrest
- Nawilżacz Whirlpool
- Nawilżacz Midea
- Nawilżacz Hisense
- Nawilżacz Nedis
- Nawilżacz Adler
- Nawilżacz Domo
- Nawilżacz Ardes
- Nawilżacz Taurus
- Nawilżacz Orbegozo
- Nawilżacz ATen
- Nawilżacz Stadler Form
- Nawilżacz Danby
- Nawilżacz Haier
- Nawilżacz Homedics
- Nawilżacz Prixton
- Nawilżacz Hyundai
- Nawilżacz Rowenta
- Nawilżacz Mesko
- Nawilżacz Master
- Nawilżacz Concept
- Nawilżacz Tripp Lite
- Nawilżacz ECG
- Nawilżacz Carel
- Nawilżacz TFA
- Nawilżacz Dyson
- Nawilżacz Trisa
- Nawilżacz Medisana
- Nawilżacz Wilfa
- Nawilżacz IFM
- Nawilżacz Clean Air Optima
- Nawilżacz Emerio
- Nawilżacz Wood's
- Nawilżacz Create
- Nawilżacz Crane
- Nawilżacz Melissa
- Nawilżacz MPM
- Nawilżacz Philco
- Nawilżacz Trotec
- Nawilżacz Velleman
- Nawilżacz Homematic IP
- Nawilżacz Klarstein
- Nawilżacz Black Box
- Nawilżacz Arendo
- Nawilżacz ATIKA
- Nawilżacz Panduit
- Nawilżacz Cecotec
- Nawilżacz Eta
- Nawilżacz Camry
- Nawilżacz Steba
- Nawilżacz Qlima
- Nawilżacz Scarlett
- Nawilżacz ResMed
- Nawilżacz TriStar
- Nawilżacz Ferrex
- Nawilżacz SPC
- Nawilżacz DCG
- Nawilżacz Vornado
- Nawilżacz Remko
- Nawilżacz Oregon Scientific
- Nawilżacz Innoliving
- Nawilżacz Argoclima
- Nawilżacz Solac
- Nawilżacz Elro
- Nawilżacz Olympia
- Nawilżacz Duronic
- Nawilżacz Comfee
- Nawilżacz Meaco
- Nawilżacz Kenmore
- Nawilżacz Breville
- Nawilżacz Terraillon
- Nawilżacz Solis
- Nawilżacz Orion
- Nawilżacz SereneLife
- Nawilżacz Vemer
- Nawilżacz Frigidaire
- Nawilżacz Gemini
- Nawilżacz Elektrobock
- Nawilżacz Hunter
- Nawilżacz Fibaro
- Nawilżacz Lanaform
- Nawilżacz Topcom
- Nawilżacz Sencor
- Nawilżacz Vonroc
- Nawilżacz Workzone
- Nawilżacz Alecto
- Nawilżacz Binatone
- Nawilżacz Suntec
- Nawilżacz JUNG
- Nawilżacz Carrier
- Nawilżacz Lund
- Nawilżacz Zibro
- Nawilżacz ProfiCare
- Nawilżacz Guzzanti
- Nawilżacz Cotech
- Nawilżacz Eurom
- Nawilżacz Proline
- Nawilżacz Lasko
- Nawilżacz OBH Nordica
- Nawilżacz Challenge
- Nawilżacz Alpina
- Nawilżacz Air Naturel
- Nawilżacz Alberello
- Nawilżacz Holmes
- Nawilżacz Korona
- Nawilżacz Jata
- Nawilżacz Eldom
- Nawilżacz Bionaire
- Nawilżacz Trebs
- Nawilżacz Soehnle
- Nawilżacz Royal Sovereign
- Nawilżacz Maxwell
- Nawilżacz Heylo
- Nawilżacz Daitsu
- Nawilżacz Vicks
- Nawilżacz Olimpia Splendid
- Nawilżacz Oasis
- Nawilżacz Duux
- Nawilżacz Imetec
- Nawilżacz Lümme
- Nawilżacz Zehnder
- Nawilżacz Mx Onda
- Nawilżacz Get
- Nawilżacz Duro
- Nawilżacz Levoit
- Nawilżacz Boneco
- Nawilżacz Venta
- Nawilżacz Turmix
- Nawilżacz Satel
- Nawilżacz EQ3
- Nawilżacz Magic Care
- Nawilżacz Arovec
- Nawilżacz Haus & Luft
- Nawilżacz Bo Jungle
- Nawilżacz Klarbach
- Nawilżacz Ebac
- Nawilżacz Minute Man
- Nawilżacz Nordmann
- Nawilżacz Okoia
- Nawilżacz Kogan
- Nawilżacz Minuteman
- Nawilżacz Condair
- Nawilżacz Air & Me
- Nawilżacz SPT
- Nawilżacz Platinet
- Nawilżacz Aktobis
- Nawilżacz PureGuardian
- Nawilżacz LightAir
- Nawilżacz Merlin
- Nawilżacz Heaven Fresh
- Nawilżacz Fral
- Nawilżacz Prem-i-air
- Nawilżacz Brune
- Nawilżacz Jotechs
- Nawilżacz Pingi
- Nawilżacz Stylies
- Nawilżacz WENKO
- Nawilżacz X4 Life
- Nawilżacz House & Luft
- Nawilżacz Plugwise
- Nawilżacz Medescan
- Nawilżacz Comfort Zone
- Nawilżacz Norpole
- Nawilżacz Cli-Mate
- Nawilżacz Respironics
- Nawilżacz Winland
- Nawilżacz Perfect Aire
Najnowsze instrukcje dla Nawilżacz
15 Października 2024
15 Października 2024
10 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
8 Października 2024
8 Października 2024