Instrukcja obsługi Honeywell HE360A1075

Honeywell Nawilżacz HE360A1075

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Honeywell HE360A1075 (32 stron) w kategorii Nawilżacz. Ta instrukcja była pomocna dla 6 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/32
OWNER’S MANUAL
69-2631ES-13
HE360 Humidifier
HE360A1075
HE360D1075
Read before installing
Input: 120 Vac, 60 Hz, 0.7A
HE360 HUMIDIFIER
69-2631ES—13 2
WELCOME
To the comfortable world of humidified air. When you use your Resideo humidifier, notice that your skin is not as
dry, and that your scratchy throat and irritated nasal passages that aggravate allergies and asthma are steadily
improving.
You have also taken the first step in reducing the zapping you create when you walk on your carpet and then
touch your TV, computer, metal door knob or your pet. Your furniture and woodwork are also benefiting from the
difference that humidified air makes.
Congratulations! You have just made a great investment in improving the comfort of your home.
INSTALLATION
Preparing for the Installation
Be sure to identify all the included accessories (Table 1) and make sure the appropriate tools and accessories
are available before beginning the installation.
Suggested Tools and Accessories
Tools required for installation include:
Tin snip.
• Screwdriver.
Adjustable or open-end wrench.
Drill, punch or awl.
• Level.
18 gauge, two-strand thermostat wire.
1/4 in. (6.35 mm) OD feed water tubing.
1/2 in (12.7 mm) ID drain tubing.
Code-compliant 1/4" water shut-off valve and fittings.
Included Accessories
Table 1. Included Accessories.
Quantity Accessory
1 bag Connecting and mounting hardware:
Wire nuts (4)
No. 8 sheet metal screws (18)
Drain tube clamp
Feed tube mounting clamps (6)
Brass inserts (2)
Plastic compression rings (2)
1 Pressure switch
1 H6062 Humidistat
HE360 HUMIDIFIER
3 69-2631ES—13
Determining Best Location for Humidifier
CAUTION
Temperature and Static Pressure Hazard.
Can cause property or equipment damage.
Locate humidifier where ambient temperature is between 32°F (0°C) and 160°F (71°C).
Do not install humidifier where freezing temperatures could occur.
Be sure supply plenum static pressure is no greater than 0.4 in. wc and water pressure is no greater than
124 psi.
Select a location for the humidifier on the supply (warm air stream) plenum. See Fig. 1.
Select a location that cannot damage the air conditioner A-coil during installation.
Do not locate the humidifier on the furnace body.
Allow adequate clearance in front of and above the humidifier so you can easily remove the cover to perform
routine maintenance.
Mount the humidifier at least 3 in. (78 mm) above the furnace body to allow adequate space for the sole-
noid valve and drain line.
Mount the humidifier in a conditioned space to prevent freezing.
Fig. 1. Typical humidifier installation locations.
Selecting Water Supply Location
Use either hard or soft water in the humidifier and either hot or cold water. The water flow rate, with the
humidifier running, is 3.5 gal/hr (13 liters/hr) to flush the pad and provide moisture for evaporation.
Make sure the length of the 1/4” of feed water tubing is adequate to connect the water supply shut-off valve
with the humidifier solenoid valve.
Locating Closest Floor Drain
Select location with access to a floor drain to provide drainage for air conditioner condensation and
humidifier drainage.
If you do not have a drain available, we recommend that you install the Resideo Whole House Drum or Disk
Humidifier. Make sure that the drain tubing is adequate to reach from the humidifier drain connection to the
floor drain.
Selecting Location for Humidistat
Select a location for the humidistat on the return plenum or on the wall in the living space.
Mounting on the return plenum is the easiest installation for the control wiring circuit.
For return duct mounting, the humidistat should be mounted upstream from the humidifier or bypass so that it
is properly sensing the relative humidi Locate the control at least 8 in. (203 mm) upstream ty of the living space.
from the humidifier in the return air duct. (See Fig 2.)
M12808C
HORIZONTAL
DOWN
FLO
LOWBOY
RETURN
RETURN
RETURN
HIGHBOY
RETURN


Specyfikacje produktu

Marka: Honeywell
Kategoria: Nawilżacz
Model: HE360A1075

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Honeywell HE360A1075, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Nawilżacz Honeywell

Instrukcje Nawilżacz

Najnowsze instrukcje dla Nawilżacz

Scarlett

Scarlett SC-985 Instrukcja

15 Października 2024
Clean Air Optima

Clean Air Optima CA-703 Instrukcja

15 Października 2024
Master

Master DHA 250 Instrukcja

10 Października 2024
Philips

Philips HU1509 Instrukcja

9 Października 2024
Philips

Philips HU5710 Instrukcja

9 Października 2024
Panduit

Panduit ACF10 Instrukcja

9 Października 2024
Panduit

Panduit ACF11 Instrukcja

9 Października 2024
Scarlett

Scarlett SC-AH986M30 Instrukcja

9 Października 2024
Sencor

Sencor SHF 7647WH Instrukcja

8 Października 2024
Prixton

Prixton Essence Instrukcja

8 Października 2024