RedLINK™ Wireless System
With Equipment Interface Module
® U.S. Registered Trademark.
Copyright © 2011 Honeywell International Inc.
All rights reserved.
System
Installation
Guide
69-2091EFS-07
Wireless control for up to 3 Heat/2 Cool heat pump systems or up to 2 Heat/2
Cool conventional systems.
Installation guide for:
Wireless equipment interface module
FocusPRO® wireless thermostats
Wireless remote control
Wireless outdoor air sensor
Return air sensor
DISCONNECT POWER BEFORE BEGINNING INSTALLATION. Can cause
electrical shock or equipment damage.
MERCURY NOTICE: If this product is replacing a control that contains mercury in
a sealed tube, do not place the old control in the trash. Contact your local waste
management authority for instructions regarding recycling and proper disposal.
Must be installed by a trained, experienced technician. Read these
instructions carefully. Failure to follow these instructions can damage the product or
cause a hazardous condition.
Fraais : voir la page 21 Español: vea la página 41
RedLINK TM
Installation Guide (EIM)
69-2091EFS—07 2
System installation at a glance
The THM5320R equipment interface module (EIM) provides control of all heating
and cooling equipment from any FocusPRO wireless thermostat.
Installation procedure
Mount and wire EIM .................................................................. Pages 3-4
Install batteries in wireless devices ...............................................Page 5
Link all devices to wireless network ........................................ Pages 5-7
Exit wireless setup ..........................................................................Page 8
Customize thermostat (installer setup) .................................. Pages 8-12
Mount thermostat and outdoor sensor .......................................Page 13
To replace system components if needed, see page 15
For system-specific wiring guides, see pages 16-17
If you have more than one Equipment Interface Module (EIM): Thermostats
are linked to specific EIMs. Optional accessories must be linked to each EIM
separately.
DISCONNECT POWER BEFORE BEGINNING INSTALLATION. Can cause electrical
shock or equipment damage.
Remote
control
Thermostat
Optional outdoor
air sensor
M28484
HVAC equipment
EIM
1
2
3
4
5
6
Français : voir la page 21 • Español: vea la página 41
3 69-2091EFS—07
M28494
1 Mount and wire EIM
Mount EIM on wall near HVAC equipment, or on the equipment itself.
Do not install inside HVAC equipment. Use screws & anchors as appropriate
for mounting surface.
EIM wiring
M28467
WIRELESS SET UP
THM5320R
CO NNECT
FLASHING: C ONN ECT ING TO REMOTE DEVIC E
RED : REMOTE DEVICE(S) NOT COM MUNICATING
GREEN: C ONN ECT ED T O R EMOT E DEVICE(S)
CO NNE CT ED
POW ER
HEAT
COOL
FAN
M28468
M28469
Install EIM Install return air sensor (optional)**
The return air sensor maintains safe
indoor temperature (62° F in Heat, 82° F
in Cool) if thermostat power is lost.
Drill 1/4” hole
(6.4mm)
Install sensor on return air duct at least
12” (305mm) upstream from ventilator,
humidifier or dehumidifier (do not mount
downstream)
Strip 1/4insulation, then insert wires
as shown.
Press tabs only to remove wires from
terminal block if necessary.
Wiring must comply with local
electrical codes.
Continued on next page >>
** For hydronic applications, use
C7189U1005 Remote Indoor Sensor and
mount in the living space.