Instrukcja obsługi Haier Smart Cool-18KC

Haier klimatyzacja Smart Cool-18KC

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Haier Smart Cool-18KC (16 stron) w kategorii klimatyzacja. Ta instrukcja była pomocna dla 4 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/16
Please read this operation manual before using the air conditioner.
Keep this operation manual for future reference.
SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
0010579916
6
7
1
2
5
Contents
PARTS AND FUNCTIONS
OPERATION
MAINTENANCE
CAUTIONS
TROUBLE SHOOTING
Do not start or stop the
operation by disconnecting
the power supply cord and
so on.
 SRVVLELOLW\RILQIODPPDEOHDo not install in the place where there is any
JDVOHDNDJHDURXQGWKHXQLW'RQRWJHWWKHXQLWH[SRVHGWRYDSRURURLO
VWHDP
1
Cautions
WARNING
3OHDVHFDOO6DOHV6HUYLFH6KRSIRUWKH,QVWDOODWLRQ
'RQRWDWWHPSWWRLQVWDOOWKHDLUFRQGLWLRQHUE\\RXUVHOIEHFDXVHLPSURSHUZRUNVPD\FDXVHHOHFWULFVKRFNILUH
ZDWHUOHDNDJH
Connect the earth cable.
earthing
WARNING
When abnormality such as burnt-small
found,LPPHGLDWHO\VWRSWKHRSHUDWLRQ
EXWWRQDQGFRQWDFWVDOHVVKRS
OFF
Use an exclusive
power source with a
circuit breaker
STRICT
ENFORCEMENT
Connect power supply cord to the
outlet completely
Use the proper voltage Do not use power supply
cord in a bundle.
Take care not to damage the
power supply cord. 1.Do not use power supply cord extendedRUFRQQHFWHGLQKDOIZD\
STRICT
ENFORCEMENT
STRICT
ENFORCEMENT PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
Do not channel the air
flow directly at people,
especially at infants or
the aged.
Do not try to repair or
reconstruct by yourself.
Do not insert objects into
the air inlet or outlet.
PROHIBITION
Do not use for the purpose of storage of
food, art work, precise equipment,
breeding, or cultivation.
CAUTION
Take fresh air occasionally especially
when gas appliance is running at the
same time.
PROHIBITION
STRICT
ENFORCEMENT
Do not operate the switch with
wet hand.
PROHIBITION PROHIBITION
PROHIBITION
PROHIBITION PROHIBITION
Do not install the unit near a
fireplace or other heating
apparatus.
Check good condition of
the installation stand
Do not pour water onto
the unit for cleaning
PROHIBITION
Do not place animals or plants in
the direct path of the air flow
Do not place any objects on or
climb on the unit. Do not place flower vase or water
containers on the top of the unit.
PROHIBITION
STRICT
ENFORCEMENT
Check proper installation
of the drainage securely
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
This appliance is not intended for use by persons (inclu ding children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
The appliances are not intended to be operated by means of an external timer or separate remote-control system.
Keep the appliance and its cord out of reach of children less than 8 years.
PROHIBITION
7KHDSSOLDQFHVKDOOEHLQVWDOOHGLQDFFRUGDQFHZLWKQDWLRQDOZLULQJUHJXODWLRQV
0HDQVIRUGLVFRQQHFWLRQVXFKDVFLUFXLWEUHDNHUZKLFKFDQSURYLGHIXOOGLVFRQQHFWLRQLQDOOSROHVPXVWEHLQFRUSRUDWHGLQWKHIL[HGZLULQJLQDFFRUGDQFHZLWKWKHZLULQJUXOHV
'HWDLOVRIW\SHDQGUDWLQJRIIXVHVRUUDWLQJRIFLUFXLWEUHDNHUV(/%LVGHWDLOHGLQEHORZSDUW
7KHPHWKRGRIFRQQHFWLRQRIWKHDSSOLDQFHWRWKHHOHFWULFDOVXSSO\DQGLQWHUFRQQHFWLRQRIVHSDUDWHFRPSRQHQWVLVGHWDLOHGLQEHORZSDUW7KHZLULQJGLDJUDPZLWKDFOHDULQGLFDWLRQ
RIWKHFRQQHFWLRQVDQGZLULQJWRH[WHUQDOFRQWUROGHYLFHVDQGVXSSO\FRUGLVGHWDLOHGLQEHORZSDUW7KHVL]HDQGW\SHRIWKHFRUGLVGHWDLOHGLQEHORZSDUW
7KHLQIRUPDWLRQRIGLPHQVLRQVRIWKHVSDFHQHFHVVDU\IRUFRUUHFWLQVWDOODWLRQRIWKHDSSOLDQFHLQFOXGLQJWKHPLQLPXPSHUPLVVLEOHGLVWDQFHVWRDGMDFHQWVWUXFWXUHVLVGHWDLOHGLQ
EHORZSDUW
,QVWUXFWLRQVRQDGGLWLRQFKDUJLQJRIUHIULJHUDQWVDUHGHWDLOHGLQEHORZSDUW
7RDYRLGGDQJHURIVXIIRFDWLQJNHHSWKLVSODVWLFEDJDZD\IURPEDELHVDQGFKLOGUHQ'RQRWXVHWKLVEDJLQFULEVEHGVFDUULDJHVRUSOD\SHQV7KLVLVQRWDWR\
Display board A
Display board B
Display board C
Display board D
1
4
2
3
1
5
Operation mode indicator
(lights up when the compressor is on.)
Timer mode indicator
(Lights up whenTimer operation is selected.)
Power indicator
(Lights up when unit starts.)
7emp display
Remote signal receiver
(A beeping sound is generated when a signal from remote controller isreceived.)
2 3 4 5
2
3
Signal receiver
1
7emp.display
2
3
Operation mode indicator
1
10.
12. SWING LEFT/RIGHT button
13.
15. SLEEP button
14. HEALTH button
16.
18. POWER ON/OFF button
20. TEMP button
21.
TIME OFF/ON button
22.
1. Mode display
1
2
3
4
5
9
10
11
12
13
14
15
16
17
8
22
23
24
25
19
20
21
18
7
6
HEALTH SLEEP EXTRA
FUNCT ION
TIME
OFF
TIME
ON
SWING
Operation mode AUTO FAN
COOL DRY
Remote controller
2. Signal sending display
4.FAN SPEED display
5. LOCK display
6. TIME OFF display
TIME ON display
7. TEMP display
3. SWING display
LO MED HI AUTO
Display
circulated
8. Additional functions display
Operation mode
Remote controller
QUIET TURBOSLEEP
Supplemented
electrical
heating HEALTH
9. TURBO button Fan speed reach
the mix value
FAN button
11. COOL button
FAN SPEED button
LOCK button
Control the lightening and extinguishing
of the indoor LED display board.
17. LIGHT button
19. DRY button
SWING UP/DOWN button
23. EXTRA FUNCTION button
24.CANCEL/CONFIRM button
Function: Setting and cancel to the
timer and other additional functions.
25. RESET button
When the remote controller appears
abnormal, use a sharp pointed
article to press this button to reset
the remote.
Healthy function is not available for some units.
TURBO
FAN
2
Parts and Functions
Remote controller
Indoor Unit
Outdoor Unit
4
OUTLET
INLET
CONNECTING PIPING
AND ELECTRICAL WIRING
DRAIN HOSE
4
Function: HEALTH AIRFLOW
AUTO FAN
---
---
10.
12. SWING LEFT/RIGHT button
13.
15. SLEEP button
14. HEALTH button
16.
18. POWER ON/OFF button
20. TEMP button
21.
TIME OFF/ON22.
1. Mode display
1
2
3
4
5
9
10
11
12
13
14
15
16
17
8
22
23
24
25
19
20
21
18
7
6
HEALTH SLEEP EXTRA
FUNCT ION
TIME
OFF
TIME
ON
SWING
Operation mode AUTO FAN HEATCOOL DRY
Remote controller
2. Signal sending display
4.FAN SPEED display
5. LOCK display
6. TIME OFF display
TIME ON display
7. TEMP display
3. SWING display
LO MED HI AUTO
Display
circulated
8. Additional functions display
Operation mode
Remote controller
QUIET TURBOSLEEP
Supplemented
electrical
heating HEALTH
9. TURBO button Fan speed reach
the mix value
HEAT button
11. COOL button
FAN SPEED button
LOCK button
Control the lightening and extinguishing
of the indoor LED display board.
17. LIGHT button
19. DRY button
button
SWING UP/DOWN button
23. EXTRA FUNCTION button
24.CANCEL/CONFIRM button
Function: Setting and cancel to the
timer and other additional functions.
25. RESET button
When the remote controller appears
abnormal, use a sharp pointed
article to press this button to reset
the remote.
Healthy function is not available for some units.
TURBO
HEAT
Function:
HEALTH AIRFLOW
AUTO FAN
---
---
Signal receiver hole
COOL display HEALTH display
4
2
3
1
5
DRY display
6
7emp.display
Actual inlet grille may vary from the one shown in the
manual according to the product purchased
2
35
6
4
HEAT display
1
(lights up when the compressor is on.)
7 emp display
3
24
1
2
3
4
Operation mode indicator
1
TIMER ON/OFF display
TIMER ON OFF display
SLEEP display
Signal receiver hole
Vertical blade
(adjust left and Display board
right air flow)
Inlet Air Purifying Filter
(inside)
Emergency
SwitchHorizontal flap
(adjust up and down air flow
Don't adjust it manually)
Outlet
Inlet grille
Cooling capacity test guidance:Step 1,press the button "ON/OFF";
step 2,press the button "COOL";step 3,press the button "TURBO".
Cooling capacity test guidance:Follow remote controller A.


Specyfikacje produktu

Marka: Haier
Kategoria: klimatyzacja
Model: Smart Cool-18KC

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Haier Smart Cool-18KC, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje klimatyzacja Haier

Haier

Haier QPCA11YBMW Instrukcja

8 Października 2024
Haier

Haier QPFA08YBMW Instrukcja

8 Października 2024
Haier

Haier QHEC05AC Instrukcja

8 Października 2024
Haier

Haier QHEK12AC Instrukcja

8 Października 2024
Haier

Haier QHEK10AC Instrukcja

8 Października 2024
Haier

Haier QHEK14AC Instrukcja

8 Października 2024
Haier

Haier QHNG10AA Instrukcja

8 Października 2024
Haier

Haier QHNG08AA Instrukcja

8 Października 2024

Instrukcje klimatyzacja

Najnowsze instrukcje dla klimatyzacja

LG

LG HS-H076QPA0 Instrukcja

15 Października 2024
Klarstein

Klarstein Vita Pure 2G Instrukcja

15 Października 2024
Gree

Gree ETAC-15HP265V20B Instrukcja

15 Października 2024
Qlima

Qlima P 126 Instrukcja

14 Października 2024
Mitsubishi

Mitsubishi MSZ-CB22VA Instrukcja

14 Października 2024
Suntec

Suntec Motion 90+ Instrukcja

14 Października 2024
Danby

Danby DTAC120B1WDB Instrukcja

14 Października 2024
Amana

Amana PTC093K35AXXX Instrukcja

14 Października 2024
Amana

Amana AMAP121AB-2 Instrukcja

14 Października 2024