01 02
RED113X
Switching relay 2gang RMD i2
audio
§
ba
NO
NC
NO
NC
C
C
RED113X
a b
i2-Bus G-Adr. T-Adr.1 T-Adr.2
Fct.1 Fct.2
NCNC C
C NONO
max 24V/1Amax 24V/1A
6LE001408B
Tehalit GmbH, Seebergstraße 37, 67716 Heltersberg, Germany +49 6333 992 0 +49 6333 992 7666 info@hager.com hager.com - 03.2023T F
Safety instructions
Electrical equipment may only be installed and
assembled by qualifi ed electricians.
Failure to comply with these instructions may
result in damage to the device, fi re or other
hazards.
When installing and laying cables, always com-
ply with the applicable regulations and stand-
ards for SELV electrical circuits.
These instructions are an integral component
of the product and must be retained by the end
user.
Function
The switching relay 2gang RMD i2Audio allows
intercom device related switching functions. The
addressing can be performed for one or two
intercom devices or for a group (max. 16) of inter-
com devices. The device has two potential-free
switching contacts that can be used for different
switching functions.
CAUTION!
The switching relay is an i2Audio
device and can only be operated on
the 2-wire bus with an audio decou-
pler.
ç
1
ba
NO
NC
NO
NC
C
C
RED113X
a b
i2-Bus G-Adr. T-Adr.1 T-Adr.2
Fct.1 Fct.2
NCNC C
C
NONO
max 24V/1Amax 24V/1A
(1) (2) (3) (4) (5)
(6) (9)(7) (10)(8) (11)
(1) Terminal a/b BUS connection
(2) Power LED: lights up as soon as the bus is
connected
(3) G-Adr: rotary switch (black) for setting the
group address
(4) T-Adr1: rotary switch (blue) for setting the fi rst
intercom device address
(5) T-Adr2: rotary switch (blue) for setting the
second intercom device address
(6) Switching contact 1: Connection of poten-
tial-free switching contact 1 (max. 24V/1A)
C = supply terminal
NC = NC contact
NO = NO contact
(7) Status LED 1: LED on = contact 1 active,
LED off = contact 1 in standby
(8) Fct.1: rotary switch (grey) for setting the
switching function 1
(9) Switching contact 2: Connection of poten-
tial-free change-over contact 2 (max. 24V/1A)
C = supply terminal
NC = NC contact
NO = NO contact
(10) Status LED 2: LED on = contact 2 active,
LED off = contact 2 in standby
(11) Fct.2: rotary switch (grey) for setting the
switching function 2
Information for electricians
Installation and electrical connection
DANGER!
Touching live parts in the installation
environment can result in an electric
shock!
An electric shock can be lethal!
Before working on the device or load,
disconnect all associated circuit
breakers. Cover all live parts in the
area!
ç
When working on systems with a 230 V AC power
connection, comply with the safety requirements of
DIN VDE 0100.
When installing door communication systems,
comply with the general safety regulations for tele-
communications systems according to VDE 0800:
- Separate routing of power and door communi-
cation cables according to VDE 0800.
- Partitions between power and door communica-
tion cables in shared trunkings.
- Use of standard telecommunications' cables, e.
g. J-Y (St) Y with 0.8 mm diameter.
Bus cables
- J-Y(ST)Y or A-2Y(L)2Y
Use wrapped wire pair.
Recommendation: white/yellow
- CAT
Use wrapped wire pair.
Recommendation: orange/white
Avoid interference!
The 13-MHz video carrier frequency used for
two-wire video door communication systems
can cause reciprocal interference with other
devices, such as radios, routers and WLAN
devices.
Only use shielded cables corresponding to
the qualities recommended in this manual.
It is essential to comply with the applicable
regulations during planning and installation.
Route cables, wire the devices, and in
particular implement shielding and earthing
measures as described below.
Connection
Connect conductor: Insert stripped conductor
(solid conductor Ø 0.4 0.8 mm).
Loosen conductor: Press orange push-button.
Remove conductor.
Figure 2: connecting terminals
If interference occurs in telecommunications
systems, radio services or other systems during
the operation of existing video door communication
systems, measures for shielding and earthing the
cables and for fi ltering must be implemented.
For this purpose, connect all of the drain wires
of the cables in a star shape using a terminal.
Connect all drain wires to the PE rail in the
distribution box.
Confi guration
A: One intercom device uses both switching
functions
On the black rotary switch G-Adr. (3) the group
address of the intercom device is set.
The rotary switches T-Adr.1 (4) and T-Adr.2
(5) are set identically to the intercom device
address.
B: Several intercom devices (max. 16) use both
switching functions together
The intercom devices must have the same
group address and sequential intercom device
addresses.
The group address is set on the rotary switch
G-Adr., the smallest intercom device address is
set on the rotary switch T-Adr.1 and the largest
intercom device address is set the on rotary
switch T-Adr.2.
C: Two intercom devices use one switching
function each
The intercom devices must have the same
group address that is set on the rotary switch
G-Adr.
The largest intercom device address is set on
rotary switch T-Adr.1 and the smallest inter-
com device address is set on the rotary switch
T-Adr.2.
Switching functions
Fct.
1/2
Switching function Time-
out
(sec.)
0 No switching function
1 Pressing the door release
button during a door call
10
2 Pressing the door release
button in standby
10
3 Pressing the door release
button during a door call or in
standby
10
4 Pressing the light button dur-
ing a door call
10
5 Pressing the light button in
standby
10
6 Pressing the light button dur-
ing a door call or in standby
10
7 Door call 10
8 Video monitor control 90/180
9 Storey call 10
A internal call 10
B Door call + storey call + inter-
nal call
10
C RED113X switching function
for relay address 0 (pulse
mode without status feedback)
10
D RED113X switching function
for relay address 1 (pulse
mode without status feedback)
10
Technical data
Operating voltage via bus 24 V=
Switching contact change-over contact
potential-free max. 24 V/1 A
Degree of protection IP 20
Relative humidity 0 ... 65% (no condensation)
Operating temperature -5 … +45°C
Storage/transport temperature -20 … +60°C
Connecting terminals plug-in terminals
Maximum conductor diameter 0.8 mm
Dimensions W x H x D 48 x 97 x 58 mm
Space units in the distributor: 3 units
§


Specyfikacje produktu

Marka: Hager
Kategoria: nieskategoryzowany
Model: RED113X

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Hager RED113X, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje nieskategoryzowany Hager

Instrukcje nieskategoryzowany

Najnowsze instrukcje dla nieskategoryzowany

Meec Tools

Meec Tools 010-084 Instrukcja

6 Października 2024
Outwell

Outwell Scenic Road 250 Instrukcja

5 Października 2024
Impact

Impact QuikBalance Instrukcja

4 Października 2024
Impact

Impact CA-112 Instrukcja

4 Października 2024
Impact

Impact LS-BHA Instrukcja

4 Października 2024
Impact

Impact LKB-5C Instrukcja

4 Października 2024
Impact

Impact RST-001 Instrukcja

4 Października 2024