Pozidrive PZ2 4.5mm
All product(s) must be installed by a suitably competent electrician
giving consideration to their intended use and in accordance with the
current edition of BS 7671 (IET Wiring Regulations).
The Electricity at Work regulations and the Health and Safety at Work
Act shall be complied with.
Only equipment and arrangements specied in Hager’s technical
documentation / catalogue shall be used
Install in the vertical plane only.
Notice:
To prevent potential overheating from loose connections the installer
shall check connections are tightened to the torque levels stated in
these instructions prior to energising this board. This check should
include factory made connections which may have loosened in transit.
JK1***BD
JK ***B1 F
JK1 Incomer Kits
Cat ref. No of Poles Description
JK11003S 3 Switch Disconnector 100A
JK11004S 4 Switch Disconnector 100A
JK11253S 3 Switch Disconnector 125A
JK11254S 4 Swtich Disconnector 125A
JK11254D 4 125A Direct Connection
JK11004RH 4 RCCB 100A 30mA
JK11004RL 4 RCCB 100A 300mA
JK11004RLD 4 RCCB 100A 300mA (Time Delayed)
JK11004RM 4 RCCB 100A 100mA
JK11004RMD 4 RCCB 100A 100mA (Time Delayed)
Designation H W D
JK104BD/BF 800 600 300
JK106BD/BF
JK108BD/BF
JK112BD/BF 12 85050
JK116BD/BF 1250 850
Warranty
This distribution board is offered with a 24 month warranty against
defective material or manufacture. If a warranty claim is necessary,
please call the technical support number given at the bottom of the page
and we will be pleased to help.
Interface Characteristics
Rated & operational voltage (U
n / Ue)
415V a.c. 50Hz
Rated insulation voltage (U
i)
690V a.c. 50Hz
Rated impulse withstand voltage (U
imp)
4kV
Rated current of the Assembly (I
nA)
JK1xxxBD (Steel Enclosure) 125A
1
JK1xxxBF (GRP Enclosure) 125A
1
1
or rating of incoming circuit / incomer kit whichever is lower
Rated current of an Outgoing circuit (I
nC)
MCB 0.5A - 63A (marked rated current on device)
RCBO 6A - (marked rated current on device)45A
Rated conditional short-circuit current of the ASSEMBLY (I
cc)
10kA
1 with equipment and arrangements specied in Hager’s technical
documentation / catalogue.
MCB/RCBO 10kA rating applied as BS EN 61439-3 is intended for use
by ordinary persons.
1
Current limitation characteristics specied in Hager’s technical
documentation / catalogue
Protection against electric shock
DBO shall be installed in an electrical system conforming to IEC 60364 /
BS 7671
Rated diversity factor (RDF) / Values of assumed loading
4 way = 0.7
6 way - 8 way = 0.6
10 way - 24 way = 0.5
Note: RDF only applies to continuously and simultaneously loaded
circuits.
Rated frequency (fn)
50 Hz
Pollution degree
2
Types of system earthing for which the ASSEMBLY is designed
TNC-S, TN-S and TT when installed in an electrical system conforming
to BS 7671
Intended locations
Indoor use only
Stationary ASSEMBLY
Degree of protection
IP with Door Closed65
IP2XC with Door Open and compliment of outgoing devices and or
blanks tted.
Intended use
Distribution boards intended to be operated by ordinary persons (DBO)
Electromagnetic compatibility (EMC) classification
EMC Environment B
External design
Wall-mounted, surface type, enclosed assembly.
Mechanical impact protection
IK07
The type of construction
Fixed parts
DBO Type
Type B DBO
Meter Kit
Cat ref. Description
JK140MID MID Multi Function Meter Pack Pulsed & Modbus
Accessories
JK01B Single Pole Blank
GB
ZD09251
2Hager Ltd. Hortonwood 50 elford Shropshire TF1 7FT • Sales Hotline: 01952 675612 • echnical Helpline: 01952 675689 ZD0T T 925
ZD0925ZD0925
Invicta 3 IP65 Enclosures
JK1SPKIT 125A Single Phasing Kit
300
300
300
300
800 600
800 600
Cat ref.
Steel Enclosure
Cat ref.
GRP Enclosure
4 1 IP65 Triple Pole Ways 25A TP&N Board - H800 x W600 x D300mm JK104BD JK104BF
6 Triple Pole Ways 125A IP65 TP&N Board - H800 x W600 x D300mm JK106BD JK106BF
8 Triple Pole Ways 125A IP65 TP&N Board - H800 x W600 x D300mm JK108BD JK108BF
12 Triple Pole Ways 125A IP65 TP&N Board - H1250 x W850 x D300mm JK112BD JK112BF
JK116BD JK116BF
16 Triple Pole Ways 125A IP65 TP&N Board - H1250 x W850 x D300mm


Specyfikacje produktu

Marka: Hager
Kategoria: nieskategoryzowany
Model: JK104BD

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Hager JK104BD, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje nieskategoryzowany Hager

Instrukcje nieskategoryzowany

Najnowsze instrukcje dla nieskategoryzowany

Meec Tools

Meec Tools 010-084 Instrukcja

6 Października 2024
Outwell

Outwell Scenic Road 250 Instrukcja

5 Października 2024
Impact

Impact QuikBalance Instrukcja

4 Października 2024
Impact

Impact CA-112 Instrukcja

4 Października 2024
Impact

Impact LS-BHA Instrukcja

4 Października 2024
Impact

Impact LKB-5C Instrukcja

4 Października 2024
Impact

Impact RST-001 Instrukcja

4 Października 2024