Overview
The energy-meters “with a blue back-lighted LCD screen for
prefect reading” are used to measure single-phase like resid-
ential, Utility and Industrial application. The unit measures
and displays various important electrical parameters, and
provide a communication port for remote reading and monito-
ring. Bi-directional energy measurement makes the unit a
good choice for solar PV energy metering.
Technical Parameters
General Specifi cations
Voltage
230Vac
Voltage range
176~276Vac
Base current(Ib)
10A
Current range
0.5~100A
Power consumption
2W/10VA
Frequen cy
50/60Hz10%)
AC vol tage withstand
4KV for 1 min ute
Impulse voltage withstand
6KV-1.2uS wavform
Max. Readin g
999999.9kWh
Accura cy
Voltage
0.5% of ra nge maximum
Current
0.5% of nominal
Frequency
0.2% of mid
-
frequency
Power factor 1% of Unity
Active power 1% of rangemaximum
Reactive power 2% of range maximum
Active energy
Class 1 IEC62053
-21
Class B EN50470 -3
Reactive energy
1% of range maximum
Enviroment
Operating temperature
-25
to +55
Storage and transportation temperature
-
40
to +70
Reference temperature
23±2
Relative humidity
0 to 95%, non
-condensing
Altitude
up to 2500m
Installation category
CAT III
Degree of pollution
2
Communi cation
Communi cation
RS485 output for Modbus RTU
Baud rate
9600
Mechanics
Din rail dimensions
36x99x63 ( WxHxD) DI N 43880
Mounting
DIN rail 35mm
Sealing
IP51 (indoor)
Material
self-
extinguishing UL94V
- 0
Unpacking
Item Number
Description
A 1
Single phase meter
B 1
RS485 cable
standard length 5m
C 1
User Manual
The Ingress Protection rate is IP51 and the pollution degree
is PD2, So meter must be install in door. The whole
installation chart shows as below:
before screw the cable. Please open the cover of meter:
The standard communication cable between meter and
inverter is 5m, if it is not enough, Customers can be exten-
ded through the network cable.
Note: be careful the wire of input and output of L/N, if lines
are wrong, it may destroy the meter.
LCD display
S
S
S
SSt
t
t
tte
e
e
eep
p
p
pp6
6
6
66.
.
.
..
When it is powered on, the meter will initialize and do self-
checking.
Full screen software version Modbus ID Baud rate total kWh
Scroll display by Button
After initialization and self-checking program, the
meter display the measured values. The default page
is total kWh. If the user wants to check other
information, he needs to press the scroll button on the
front panel.
The display order by scroll button
Total kwh import kwh export kwh resettable
kwh total kVarh import kVarh export kVarh
resettable kVarh Max. power demand voltage
current W Var VA power factor frequency
pulse constant Modbus ID baud Fate continuous
running time.
Single-phase Meter User Manual
Installation
S
S
S
SSt
t
t
tte
e
e
eep
p
p
pp5
5
5
55.
.
.
..
Wire diagram:
Item Descriptions
17 digits used to display measured values or RTC
2Total value
4Import information, Export information
5Max. Demand for Power or Current
6Pulse output 1 and Pulse ou
tput 2
7Measurement units
8PF = power factor Hz = frequency
9Bar display of Power
10 Communication indicator
11 Time information
12 Low battery warning
13 Lock symbol
SDM230-Modbus


Specyfikacje produktu

Marka: Growatt
Kategoria: Niesklasyfikowane
Model: SPM

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Growatt SPM, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Growatt

Growatt

Growatt MOD 3-10KTL3-XA Instrukcja

9 Października 2024
Growatt

Growatt SPF6000ES PLUS Instrukcja

9 Października 2024
Growatt

Growatt SPI 3000-22000 Instrukcja

9 Października 2024
Growatt

Growatt MID 17-22KTL3-X Instrukcja

9 Października 2024
Growatt

Growatt Shine GPRS-F Instrukcja

9 Października 2024
Growatt

Growatt SEM-E Instrukcja

8 Października 2024
Growatt

Growatt Shine WiFi Instrukcja

8 Października 2024
Growatt

Growatt MID 17-40KTL3-X Instrukcja

8 Października 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024