Introduction
The Auto-Transfer Switch Three Phase (ATS T)controls the switching of the contactors to provide power to the EPS load in both grid-tied
and off-grid conditions. The ATS-T integrates a contactor to provide users with a simple connection. It is used with Growatt Hybrid inverter
and AC coupled inverter (Three phase). Configured with ATS-T, when the power outage, ATS-T can automatically switch to Off-Grid state, it
can continue to supply power to the EPS load, the load can continue to run.
-
2
2
2
22.
.
.
..
The location of ATS T in the system-
8
8
8
88.
.
.
..
4
4
4
44.
.
.
..
General Information - Parts List
3
3
3
33.
.
.
..
Configuration
7
7
7
77.
.
.
..
9
9
9
99.
.
.
..
Model Name
Growatt ATS T-
Grid Normal Voltage
230/400a.c.V 50/60Hz
Grid Max Current
30A
EPS Normal Voltage
230/400a.c.V 50/60Hz
EPS Max Current
30A
Load Normal Voltage
230/400a.c.V 50/60Hz
Load Max Current
30A
Cooling Concept
Natural
Ingress Protection
IP65
Installation
Wall Mountable
-25 +50℃ ~
Compatible Model
Operation Ambient
Temperature
Growatt Hybrid inverter and AC
coupled inverter (three phase )
Opening step of ATS-T Open the ATS-T
As shown above, please put the key into the Keyhole on the ATS T
right, clockwise rotation of 90°, the lower end of the first lock up
gently move Open, remove the lock at the upper end of the buckle,
then you can open the cover, Step of locking the cover opposite to
the above.
-
Wiring Connection
There are two type wire connection diagram of ATS T, show as below:-
9.1 total wire diagram
300mm
300mm
300mm
300mm
As shown in chart 2.1, the input side is connected with
EPS and GRID of Hybird inverter, the output side is connected
with EPS LOAD, and the position in the system is shown in the
circle in the chart 2.1. EPS LOAD default connect with Grid
power, if Grid is lost, EPS LOAD will turn to EPS output of hybrid
inverter.
ATS-T
D E F G
A B C
A
B
C
D
E
F
G
Item ItemItem Name Item NameQty Qty
ATS-T Auto-Transfer Switch
Three Phase
User Manual
Anchor Bolt
O -type terminal
12
1 20
2 4
3
Key
Cold pressed terminal(large /small)
Contactor control line
Part List Part List
5
5
5
55.
.
.
..
Dimension & Weight
Dimension (L x W x H) 312*295*85mm
Weight : 3.8KG
6
6
6
66.
.
.
..
Tool
NO NO
1
2
3
4
5
Description Description
Pipe clamp
Diagonal plier
Screwdriver
Rubber hammer
Driller
1.To leave at least 300mm
space from ATS-T
2.Make the position of 2
holes(282mm) .
3.Drill holes with drill φ10
Depth: at least 40mm.
ab
c
1. Wires below are needed before installation(16AWG wire
has been configured in accessory bag).
9.2 wires making
2.Use the diagonal plier to trip 15mm of insulation from one side of
the 10AWG wires(12pcs);
Use the diagonal plier to trip 15mm of insulation from two side of
the 10AWG wires (4pcs,If it is standard 2, you need 5pcs);
Use the diagonal plier to trip 10mm of insulation from two side of
the 12AWG wires(4pcs);
Use the diagonal plier to trip one side of GND wire about
7mm(3pcs).
2
Note:
1.These include 4pcs 10AWG wire (2pcs red, 2pcs black) for
shorting contactor ports 2 and 4, 6 and 8(each contactor), Its length
is about 60cm, 10 AWG N wire (for standard2)length is about 50cm.
Standard 1 is for general using, and standard 2 is for like Australia where Neutral line can't be switched. When connect with ATS T,
please check which standard is suit for you.
-
After connecting the ATS T internal wire, close the cover, the
GRID and EPS end of the ATS-T are respectively connected
with the AC GRID and EPS output of Hybird inverter, EPS load
end access load, run Hybird inverter, load to normal operation.
-
ATS T usage methods-
1
1
1
111
1
1
11.
.
.
..
Shenzhen Growatt New Energy Technology CO.,LTD
No.28 Guangming Road, Shiyan Street, Bao’an District,
Shenzhen, P.R.China
No.28 Guangming Road, Shiyan Street, Bao’an District,
Shenzhen, P.R.China
GR UM 163 A 01GR UM 163 A 01- - - -- - - -
+86 0755 2747 1942 +86 0755 2747 1942
www.ginverter.comwww.ginverter.com
T
E
W
service@ginverter.comservice@ginverter.com
Download
Manual
Growatt New Energy
9.4 GRID-wires Connection
9.3 Control coil-wires Connection
9.6 EPS LOAD-wires Connection
3.There are three types wire need to be machining, please check
ref to section 9.1 wired diagram. The follow three type wire are
show as below:
abc
9.5 EPS-wires Connection
Use the screwdriver to unscrew the nut with position
numbers 3 and 5(each contactor) in the contactor, and then
insert EPS-R, EPS-S,EPS-T wires and EPS-N wires into the
port of contactor(3&5) through the cable nut and tighten them
with screwdriver. Use a screwdriver to lock the ground wire
on the E-wire copper bar.
Note
Please prevent other wires from getting loose during
operation.
Use the screwdriver to unscrew the n ut with position numbers 2,
4, 6 and 8(each contactor) in the contactor, and the red 10AWG
short wire ends were inserted into the contactor port 2 and 4,
The Black 10AWG short wire ends were inserted into the
contactor port 6 and 8, then insert EPS load-R,EPS load-S,EPS
lo a d -T wi res and EPS l o ad-N wir es into th e po rt of
contactor(2&6) through the cable nut and tighten them with
screwdriver. Use a screwdriver to lock the ground wire on the E-
wire copper bar.
Use the screwdriver to unscrew the nut with posi tion numbers
R1 and R7(each contactor) in the contactor, and then insert
GRID-R,GRID-S,GRID-T wires and GRID-N wire into the port
of contactor(R1&R7) through the cable nut and tighten them
with screwdriver. Use a screwdriver to lock the ground wire
on the E-wire copper bar.
Use the screwdriver to unscrew the nut with position numbers 5
and 7(contactor2) in the contactor, and use 10 AWG wire shorting
contacts 2 of 5 and 7 ports and tighten with a screwdriver.
Note:
The following step is an example for Australian grid system
where neutral line can't be switched. (If you do not have this
requirement, ignore the following step)
9.7 Checking
P l e a s e m a k e s u r e t h a t a l l w i r i n g i n t h e AT S T i s
tightened check the connection diagram with section 9.1.
-
In the process of use, if the EPS load does not work when the
on-grid, please turn off the Hybird inverter, and then open the
ATS-T cover, check the GRID and EPS LOAD line is connected
properly.
If the load does not work when off-grid, please turn off the
inverter, and then open the ATS-T cover, check the control line,
the EPS wiring and the EPS LOAD wiring is normal.
1
1
1
110
0
0
00.
.
.
..
Trouble shooting
Caution
Please use the equipment within the scope of specification.
Excessive current or voltage may cause device damage
To avoid personal injury due to energy hazard, remove
wristwatches and jewelry when repairing. Use tools with
insulated handles.
Repair are to be performed only by qualified technical personal
authorized by Growatt.
1
1
1
112
2
2
22.
.
.
..
A EPS-R wire Connect to EPS-R
B
C
D
E
F
Control coil-L wire1
EPS-N wire
Control coil-N wire1
Control coil-N wire2
Control coil-L wire2
Connect the contactor 1 of 3 and A1
Connect to EPS-N
Connect the contactor2 of 5 and A2
Connect the contactor 2 of 5 and
contactor 1 of A2
Connect the contactor 1 of 3 and
contactor 2 of A1


Specyfikacje produktu

Marka: Growatt
Kategoria: Niesklasyfikowane
Model: ATS-S

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Growatt ATS-S, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Growatt

Growatt

Growatt MOD 3-10KTL3-XA Instrukcja

9 Października 2024
Growatt

Growatt SPF6000ES PLUS Instrukcja

9 Października 2024
Growatt

Growatt SPI 3000-22000 Instrukcja

9 Października 2024
Growatt

Growatt MID 17-22KTL3-X Instrukcja

9 Października 2024
Growatt

Growatt Shine GPRS-F Instrukcja

9 Października 2024
Growatt

Growatt SEM-E Instrukcja

8 Października 2024
Growatt

Growatt Shine WiFi Instrukcja

8 Października 2024
Growatt

Growatt MID 17-40KTL3-X Instrukcja

8 Października 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024