E-1
USE & CARE INSTRUCTIONS
4-in-1
Allergen and Odor Reducing
Air Cleaning System
Model No. AC5900
3-Year Limited Warranty
Customer Service
1.866.603.5900
www.guardiantechnologies.com
Date Purchased month ________ year _________
English French Spanish E - 1 F - 1 S - 1
Use GENUINE Guardian Technologies replacement parts only.
REV0 209
LIMITED WARRANTY
Clean Air Delivery Rate
From air cleaner to air cleaner, compare the CADR numbers. First look at suggested room size. Then referto the Clean Air
Delivery Rate (CADR) numbers. The higher the number, the faster the unit filters the air.
What is CADR?
CADR stands for “Clean Air Delivery Rate,” which indicates the volume of filtered air delivered by an air purifier. CADR ratings
show the effectiveness of how efficient the air purifier is at capturingfine particles from things like tobacco smoke and plant
pollens from the room.
Refer to website for individual model CADR numbers.
TROUBLESHOOTING GUIDE
PROBLEM SOLUTION
Unit shuts off unexpectedly
or does not operate.
Check that the unit is plugged into a working electrical outlet.
Check that the filters, UV-C shield and front panel are installed correctly.
Check the motor protector triggered. Unplug/replug into unit. Check if is
that the front panel is latched firmly in place.
Call Customer Service.
No air circulating from unit. Unplug unit. Check filters. Clean Pre-filter if necessary.
Replace Charcoal and HEPA filters if necessary.
Increase in noise level. Make sure the filters are clean. Replace if necessary.
Odors and smoke are not removed. Clean or replace the filters if they appear to be heavily soiled.
Discharged air has an aroma or odor. Check to see if the filters are heavily soiled. Replace the filters.
To the consumer, Guardian Technologies LLC warrants this product to be free of defects in materials or workmanship commencing
upon the date of the original purchase. In order to be eligible for this Limited Warranty, an original sales receipt or comparable substitute
proof of purchase bearing the date of original purchase is required. Refer to the original product carton or specific product/model page
on the Guardian Technologies website for warranty length for your particular model. This warranty applies only to the original purchaser
of this product from the original date of purchase. This warranty covers product purchased from authorized distributors only.
This warranty applies to repair or replacement of product found to be defective in materials or workmanship. This warranty does not
apply to damage resulting from unusual wear, commercial, abusive, unreasonable use or supplemental damage. This warranty does
not cover damage from unauthorized repairs or from any use not in accordance with the instruction manual. Defects that are the result
of normal wear and tear will not be considered manufacturing defects under this warranty.
If this product should become defective within the warranty period, we will repair or replace any defective parts free of charge. All
warranty repairs must be completed by Guardian Technologies LLC. This warranty gives you specific legal rights and you may also have
other rights (other rights may vary from state to state in the U.S.A.)
To submit product under warranty the complete machine must be delivered pre-paid to GuardianTechnologies LLC. Please include
complete information including: the problem, the model number of the product, the day of purchase, and a copy of the original sales
receipt along with your name, address, and telephone (email optional). Address returns to the attention of: Customer Service, at the
address below. Additional questions or comments can be made toll free to the number listed below.
Additional copies of the instruction manual can be obtained by accessing and
printing directly from our website or calling customer service.
USA and Canada
Guardian Technologies LLC
26251 Bluestone Blvd.
Euclid, Ohio 44132
1.866.603.5900
www.guardiantechnologies.com
Please go to www.guardiantechnologies.com to register your product. We
consider the registration process important to ensuring superior service to our
customers, however submitting the warranty registration is optional and does not
affect your rights to utilize this warranty according to the conditions stated above.
READ AND SAVE THESE INSTRUCTIONS
WARNINGS
Failure to comply with the warnings listed below may
result in electric shock or serious injury.
When using electrical appliances, basic precautions should always be followed to reduce the risk
of fire, electric shock and injury to persons, including the following:
Read all instructions before using appliance.
IMPORTANT - This appliance has a polarized plug (one blade is wider than the other). To reduce
the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the
plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified
electrician. Do not attempt to defeat this safety feature.
Extreme caution is necessary when any appliance is used by or near children or people with
disabilities and whenever the appliance is left operating unattended.
To avoid fire or shock hazard, plug the appliance directly into a 120V AC electrical outlet.
Keep the cord out of heavy traffic areas. To avoid fire hazard, NEVER put the cord under rugs,
near heat registers, radiator, stoves or heaters.
To protect against electrical hazards, DO NOT immerse in water or other liquids.
Do not use near water.
Extreme caution is necessary when any appliance is used by or near children or people with
disabilities and whenever the appliance is left operating unattended.
Always unplug the air purifier before moving it, opening the grill, changing filters, cleaning or
whenever the air purifier is not in use. Be sure to pull by the plug and not the cord.
NEVER drop or insert any object into any openings.
DO NOT run cord under carpeting.
DO NOT cover cord with throw rugs, runners, or similar coverings.
DO NOT route cord under furniture or appliances. Arrange cord away from traffic area and
where it will not be tripped over.
DO NOT operate any appliance with a damaged cord or plug, if motor fan fails to rotate, after
the appliance malfunctions, or if it has been dropped or damaged in any manner. Call Customer
Service for assistance.
Use appliance only for intended household use as described in this manual. Any other use not
recommended by the manufacturer may cause fire, electric shock or injury to persons.
DO NOT use outdoors.
DO NOT place anything on top of unit.
NEVER block the air openings, grills/outlets or place on a soft surface such as a bed or sofa, as
this could cause the unit to tip over, blocking the air intake or outtake opening.
E-2 E-3
This product should be used only in accordance with the specifications outlined
in this manual. Usage other than what has been specified here may result in
serious injury.
LAMP CONTAINS MERCURY
Manage in accordance with Spills, Disposal and Site Cleanup Requirements.
In case of breakage, follow clean-up procedures provided by contacts below.
www.epa.gov/cflcleanup 1-866-284-4010
DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so
will void your warranty. The inside of the unit contains no user serviceable parts. All servicing
should be performed by qualified personnel only.
WARNING: To reduce the risk of fire or electric shock, do not use this fan with any
solid-state speed control device.
WARNING: Skin or eye damage may result from directly viewing the light produced by the
lamp in this apparatus. Always disconnect power before replacing lamp or servicing.
Replace Lamp With Lamp Model No. LB4000, Manufactured by Guardian Technologies.
Always unplug the unit before before cleaning or servicing in any way.
CAUTION: Do NOT use gasoline, benzene, thinner, harsh cleaners, etc. on and/or in the
unit while cleaning as they will damage the product. NEVER use alcohol or other solvents.
The 8 hour TWA Ozone for this product is 0.001 ppmv when tested in a 30 m3 chamber. The
product complies with the maximum allowable concentration of ozone of 0.050 parts per million
by volume (ppmv) in a 24-hour period. The Health Canada Guideline 2010 recommends that
the maximum exposure limit, based on averaging time of 8 hours, is 0.020 ppmv or less when
tested in a sealed, controlled room approximately 30 m3.
WARNING: Cancer and Reproductive Harm.
For more information go to www.P65Warnings.ca.gov.
This product earned the ENERGY STAR label by meeting strict energy efficiency
guidelines set by the U.S. EPA. Room air cleaners have demonstrated the potential
for improving air quality and providing health benefits. EPA does not endorse
manufacturer claims regarding the degree to which a specific product will produce
healthier indoor air. The energy efficiency of this ENERGY STAR certified model is
measured based on a ratio between the model’s CADR for Smoke and the electrical
energy it consumes, or CADR/Watt.
PRODUCT SPECIFICATIONS AND PARTS
E-4
AIR CLEANING SYSTEM
Improve your indoor air quality with your new Germguardian ® Air Cleaning System.
Multiple levels of cleaning include a combination True HEPA filter that captures allergens,
and Charcoal filter to remove odors. UV-C Light Technology enhances germ-killing.
Pre-Filter/Activated Carbon
Helps optimize the unit performance and extends the life of the filter by capturing larger dust
and allergen particles. Traps and controls household odors and harmful VOC’s in the home.
True HEPA Filter
Captures 99.97% of dust and allergens down to .3 microns in size.
UV-C Light
UV-C Light Technology works with Titanium Dioxide (TiO2) to enhance the elimination of
airborne germs. TiO2 is activated by the UV-C light to decompose remaining odor molecules
caused by smoking, cooking and pets.
AIR CLEANING LAYERS
Carrying
Handle
Air Outlet
Power Cord
Base
Front Panel
Filters
Control Panel
Unit Body
MODEL NUMBER: DIMENSIONS: WEIGHT: AC5900 9.65”L x 15.95”W x 20.87”H 13 lbs
REPLACEMENT PARTS
FILTER:
Filter
Model No. FLT5900
JUV-C BULB (5W):
Model No. LB4000
E-5
UV-C Ti02
Treated
Shield
HEPA Filter
Pre-Filter/
Activated Carbon
UV-C
Light Bulb
Check out our
Filter Replacement Program
www.guardiantechnologies.com
IMPORTAN : To maintain the performance of the air cleaner, use T
Guardian Technologies GENUINE Replacement Parts only.
To Purchase Contact Customer Service


Specyfikacje produktu

Marka: GermGuardian
Kategoria: oczyszczacz powietrza
Model: AC5900

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z GermGuardian AC5900, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje oczyszczacz powietrza GermGuardian

Instrukcje oczyszczacz powietrza

Najnowsze instrukcje dla oczyszczacz powietrza

Ulsonix

Ulsonix AIRCLEAN 20G Instrukcja

15 Października 2024
Winix

Winix AUS-5500 Instrukcja

14 Października 2024
Gorenje

Gorenje H08WB Instrukcja

9 Października 2024
Ufesa

Ufesa PF4500 Instrukcja

9 Października 2024
Ufesa

Ufesa PF3500 Instrukcja

9 Października 2024
Samsung

Samsung AX32BG3100GB Instrukcja

9 Października 2024
GE

GE AHG50LE Instrukcja

9 Października 2024
Miele

Miele PAC 1200 Instrukcja

9 Października 2024