Installation
Instructions
WARNING Use in unapproved appliance may
result in risk of fire or electric shock. This range
hood cord connection kit should be used only
with GE Appliances series range hood models
AV447, CVW9, JN327, JV338, JV247, JV248,
JV347, JV348, JV367, JV566, JV565, JV535, JV536,
JV635, JV636, JV665, JV666, JVE40 JVX3240,
JVX3300, JVX5300, JVX5360, JVX5305, JVX5365,
PVX7300, PVX7360, RN328, UVC7, UVC9, UVW8,
UVW9, ZVW13 and ZVW14.
BEFORE YOU BEGIN
Read these instructions carefully and completely.
IMPORTANT Save these instructions
for local inspector’s use.
IMPORTANT Observe all governing
codes and ordinances.
Note to Installer Be sure to leave these
instructions with the consumer.
Note to Consumer Keep these instructions for
future reference.
Skill Level Installation of this power cord kit
requires basic mechanical skills. Proper installation
is the responsibility of the installer. Product failure
due to improper installation in not covered under
the GE Appliances Warranty.
WARNING Improper grounding can result
in a risk of electric shock. The appliance must be
grounded. The plug must be plugged into an outlet
that is properly installed and grounded. Consult a
qualified electrician if the grounding instructions are
not completely understood, or if doubt exists as to
whether the appliance is properly grounded. Do not
use an extension cord. If the power supply cord is
too short, have a qualified electrician install an outlet
near the appliance.
Range Hood
Power Cord Kit
JXHC1
TOOLS NEEDED
PARTS INCLUDED
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of
an electrical short circuit, grounding reduces the risk
of electric shock by providing an escape wire for
the electric current. This appliance is equipped with
a cord having a grounding wire with a grounding
plug. The plug must be plugged into an outlet that is
properly installed and grounded.
READ AND SAVE THESE INSTRUCTIONS
If you have questions, call GE Appliances at 800.GE.CARES (800.432.2737)
or visit our website at: GEAppliances.com.
31-2000897 Rev. 0 02-21 GEA
Flat blade and
Phillips head screwdrivers
1/4" NutdriverWire cutters/
strippers
PART QUANTITY
Power Cord with Strain Relief 1
Wire Nuts 3
Installation Instructions 1
231-2000897 Rev. 0
Installation Instructions
1 REMOVE CONNECTION BOX
COVER
Locate the hood connection box and remove its cover.
5 CONNECT THE CORD WIRES
Inspect the junction box wires to determine the type of
connections that should be made.
For hoods with a ground screw:
A Connect the green ground wire to the green
ground screw.
B Using the wire nuts provided, connect the black
power cord lead to the stripped black lead and the
white power cord lead to the stripped white lead in
the connection box.
C All electrical connections should be inspected
carefully before replacing the connection box
cover.
For hoods with a ground wire:
A Using the (2) wire nuts provided, connect the
black power cord lead to the black junction box
lead. Connect the white power cord lead to the
white junction box lead.
B Locate the power cord green ground wire, and cut
off the ring terminal and strip 1/2” of insulation.
C Using the third wire nut, connect the power cord
ground wire to the green junction box lead.
D All electrical connections should be inspected
carefully before replacing the junction box cover.
2 REMOVE KNOCKOUT
Insert the blade of a flat blade screwdriver into the
preferred knockout slot and bend until the knockout
is removed.
3 THREAD WIRES THROUGH THE
KNOCKOUT
Thread the cord wires through the knockout hole.
6 REPLACE CONNECTION BOX
COVER
Replace the connection box cover using the screws
removed in Step 1.
7 INSTALL HOOD
Return to and proceed with the Installation Instructions
to install the range hood.
4 PULL CORD THROUGH THE
KNOCKOUT
From inside of the hood junction box, thread wires
through the strain relief nut and tighten down nut
until secure.
Printed in China


Specyfikacje produktu

Marka: GE
Kategoria: piekarnik
Model: JXHC1

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z GE JXHC1, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje piekarnik GE

GE

GE JB710WHWW Instrukcja

15 Października 2024
GE

GE Adora JBP73HLBB Instrukcja

14 Października 2024
GE

GE JGP330SEKSS Instrukcja

14 Października 2024
GE

GE JBP62BMWH Instrukcja

9 Października 2024
GE

GE PC2S930YPFS Instrukcja

8 Października 2024
GE

GE Profile PB911DJBB Instrukcja

8 Października 2024
GE

GE JP346BMBB Instrukcja

7 Października 2024
GE

GE Profile JS966KDCC Instrukcja

7 Października 2024
GE

GE JBP68SHSS Instrukcja

6 Października 2024
GE

GE JBP84DMBB Instrukcja

6 Października 2024

Instrukcje piekarnik

Najnowsze instrukcje dla piekarnik

Wolf

Wolf M Series Instrukcja

15 Października 2024
Princess

Princess 112741 Instrukcja

15 Października 2024
Boretti

Boretti VFPNR 1202 IX Instrukcja

15 Października 2024
Ilve

Ilve MDC-120 Instrukcja

15 Października 2024
Frigidaire

Frigidaire FCWD2727AW Instrukcja

15 Października 2024
AEG

AEG IKK74545FB Instrukcja

15 Października 2024
Ilve

Ilve HCPT75D Instrukcja

15 Października 2024
Zanker

Zanker KOU65902XK Instrukcja

15 Października 2024
Hoover

Hoover PHC3B25CXHH64DCT Instrukcja

15 Października 2024