Instrukcja obsługi Furman M-8x AR


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Furman M-8x AR (28 stron) w kategorii Niesklasyfikowane. Ta instrukcja była pomocna dla 4 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/28
10001883-A
M-8x AR
Instructions
GRE EN - OK
YEL- LIMIT ED
RED - NOT OK
100 105 110 115 120 125 130 135
LOW
EVS
WITHIN
REG
PROTECTION
OK
HIGH
EVS
EXTREME
CURRENT
INCOMING VOLTAGE
120 VAC LINE VOLTAGE REGULATOR
REGULATED OUTLET
15 AMPS
PUSH TO RESET
M-8x AR
ON
OFF
15A 120V 50-60 Hz
MAIN POWER
100 105 110 115 120 125 130 135
LOW
EVS
WITHIN
REG
PROTECTION
OK
HIGH
EVS
EXTREME
CURRENTINCOMING VOLTAGE
120 VAC LINE VOLTAGE REGULATOR REGULATED OUTLET
15 AMPS
PUSH TO RESET
M-8x AR
ON
OFF
15A 120V 50-60 Hz MAIN POWER
120 VAC
50/60 Hz
15A MAX
120 VAC
50 - 60 Hz
MAX LOAD
15 AMPS
MADE IN CHINA
C US
GREEN - OK
YEL - LIMITED
RED - NOT OK
Core Bra nds / Furman / 152908
VOLTAGE REGULATED OUTLETS
AC Line Voltage Regulator
M-8x AR
For more information:
Para más información
Pour plus de renseignements:
877-486-4738 / www.furmansound.com
1
1. Please read and observe all of the safety and operating instructions before the M-8x AR is operated or connected to mains power.
2. Retain these instructions for future reference.
3. The M-8x AR should not be used near water for example, near a bathtub, kitchen sink, in a wet basement, near a swimming pool, etc.
4. Do not place the M-8x AR near sources of heat; such as radiators, heat registers, stoves, or other appliances that produce heat.
5. Route the power cord and other cables such that they are not likely to be walked on, tripped over, or stressed. Pay particular attention to the condition of
cords and cables at plugs, and the point where they exit from the M-8x AR. To prevent risk of fire or injury, damaged cords and cables should be replaced
immediately.
6. Clean the M-8x AR using a damp cloth only. Do not use solvents or abrasive cleaners. Never pour or spray any liquid on or into the M-8x AR.
7. When left unused for an extended period of time, the power cord of the M-8x AR should be unplugged from the outlet.
8. The M-8x AR should be serviced by qualified service personnel when:
a. The power supply cord or the plug has been frayed, kinked, cut, or damaged.
b. Objects have fallen into or liquid has spilled into the unit.
c. The M-8x AR does not appear to operate normally or exhibits a marked change in performance.
d. The M-8x AR has been dropped, or the enclosure damaged.
9. The M-8x AR requires that a safety ground be present for proper operation. Any attempt to operate the M-8x AR without a safety ground is considered
improper operation and could invalidate the warranty.
• Provides nine regulated, conditioned AC outlets-eight on the rear panel and one on the front
• Input capacity is 15 A; output capacity is 12 to 15 A
• Extreme over-voltage (instant) shutdown and under-voltage (delayed) shutdown, safeguard connected equipment
• Extreme Voltage Shutdown (EVS) indicator LED
• Extreme over-current shutdown protects regulator and connected equipment.
• Extreme Current Shutdown (ECS) indicator LED
Tri-color “In-Regulation” indicator
• Protection OK indicator
• Eight element, Bi-color bar graph meter to indicate input line voltage
• User accessible thermal circuit breaker protects against overload
• Low noise toroidal autotransformer with very low stray magnetic field leakage
• Front Panel ON/OFF switch
• Compact, lightweight unit weighs only 15 lbs. (6.8 kg)
To obtain best results from your Furman M-8x AR please be sure to read this manual carefully.
WARNING: To reduce the risk of electrical shock, do not expose your M-8x AR to rain or moisture.
Hazardous voltages are present inside the enclosure. Please do not remove the cover for any reason. There are no user serviceable parts inside.
Refer servicing to qualified service personnel.
FEATURES
IMPORTANT SAFETY INSTRUCTIONS PLEASE READ PRIOR TO INSTALLATION
INTRODUCTION
Thank you for purchasing a Furman M-8x AR AC Line Voltage Regulator and congratulations on your choice. The M-8x AR has been designed with the unique
requirements of the entertainment industry in mind. Any application that requires clean,ltered, protected and regulated AC power for optimum performance
would benefit from the use of an M-8x AR.
GR EEN - OK
YEL- LI MITED
RE D - NO T OK
100 105 110 115 120 125 130 135
LOW
EVS
WITHIN
REG
PROTECTI ON
OK
HIGH
EVS
EXTREM E
CURRENT
INCOMING VOLTAGE
120 VAC LINE VOLTAGE REGULATOR
REGULATED OUTLET
15 AMPS
PUSH TO RESET
M-8x AR
ON
OFF
15A 120V 50-60 Hz
MAIN POWER
www.furmansound.com 877-486-4738 2
Please read IMPORTANT SAFETY INSTRUCTIONS
• No serviceable parts.
• Please inspect the unit thoroughly.
• Please contact Furman Customer Service at 800-472-5555, if there is any noticeable damage to product or product does not operate correctly.
Contents of this package include:
• M-8x AR
• Instruction Manual
BEFORE YOU BEGIN, INSPECT UPON RECEIPT
The Furman M-8x AR Voltage Regulator is intended to protect sensitive electronic equipment from problems caused by AC line voltage irregularities such
as brownouts, sags, and over-voltage conditions. Such irregularities can cause audio tonal changes, digital equipment malfunctions (such as loss of MIDI
programs or other data), or in extreme cases, permanent damage. The M-8x AR can accept input voltages over a wide range (see tables below) and convert
this to a steady, stable 120VAC +/- 5V output.
AC LINE VOLTAGE REGULATOR
The M-8x AR has eight receptacles on the rear panel, and one on the front panel, all are functionally in-
terchangeable. The receptacles are regulated, spike-suppressed, and filtered against RFI with a 3-pole
filter, making the M-8X AR a full-function power conditioner. The M-8x AR has no external controls
other than an on-off switch.
Note: The M-8x AR is designed for use with AC voltage only and DC voltages should never be applied.
Also, the M-8x AR does not change or regulate the line frequency in any way. The output frequency will
always be the same as the incoming line frequency.
Maximum and Minimum Load:
The M-8x AR can handle loads totaling up to 15 amperes as long as the input voltage is greater than or
equal to 124 Volts. For voltages below 124 Volts, the nominal 15 Amp current handling capacity must
be de-rated at approximately 113 milliamps per volt below 124 VAC.
To successfully handle worst-case brownout conditions, you should plan your total load so that it does
not exceed 12 amps, or 1400 watts under brownout conditions. Please note that the total load refers
to the combined current demand of all devices plugged into the M-8x AR, not just each individual
receptacle, or load.
75 80 90 100 110 120 130 140 145 160
140
130
120
110
100
90
80


Specyfikacje produktu

Marka: Furman
Kategoria: Niesklasyfikowane
Model: M-8x AR

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Furman M-8x AR, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Furman

Furman

Furman M-10X E Instrukcja

8 Października 2024
Furman

Furman M-10LX E Instrukcja

8 Października 2024
Furman

Furman ELITE-15 DM i Instrukcja

8 Października 2024
Furman

Furman Elite-10E i Instrukcja

8 Października 2024
Furman

Furman CN-3600SE Instrukcja

7 Października 2024
Furman

Furman ASD-120 2.0 Instrukcja

7 Października 2024
Furman

Furman PLUGLOCK Instrukcja

7 Października 2024
Furman

Furman SPR-16E i Instrukcja

7 Października 2024
Furman

Furman PST-8D Instrukcja

7 Października 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024