Strona 1/36
®
80 Series V
Digital Multimeter
Calibration Manual
PN 2102915
September 2004, Rev.1, 2/05
© 2004-2005 Fluke Corporation, All rights reserved. Printed in USA
All product names are trademarks of their respective companies.
Lifetime Limited Warranty
Each Fluke 20, 70, 80, 170 and 180 Series DMM will be free from defects in material and workmanship for
its lifetime. As used herein, “lifetime” is defined as seven years after Fluke discontinues manufacturing the
product, but the warranty period shall be at least ten years from the date of purchase. This warranty does
not cover fuses, disposable batteries, damage from neglect, misuse, contamination, alteration, accident or
abnormal conditions of operation or handling, including failures caused by use outside of the product’s
specifications, or normal wear and warranty covers the original tear of mechanical components. This
purchaser only and is not transferable.
For ten years from the date of purchase, this warranty also covers the LCD. Thereafter, for the lifetime of
the DMM, Fluke will replace the LCD for a fee based on then current component acquisition costs.
To establish original ownership and prove date of purchase, please complete and return the registration card
accompanying the product, or register your product on http://www.fluke.com. Fluke will, at its option, repair
at no charge, replace or refund the purchase price of a defective product purchased through a Fluke
authorized sales outlet and at the applicable international price. Fluke reserves the right to charge for
importation costs of repair/replacement parts if the product purchased in one country is sent for repair
elsewhere.
If the product is defective, contact your nearest Fluke authorized service center to obtain return authorization
information, then send the product to that service center, with a description of the difficulty, postage and
insurance prepaid (FOB Destination). Fluke assumes no risk for damage in transit. Fluke will pay return
transportation for product repaired or replaced in-warranty. Before making any non-warranty repair, Fluke
will estimate cost and obtain authorization, then invoice you for repair and return transportation.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A
PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE SHALL NOT BE LIABLE FOR ANY
SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS
OF DATA, ARISING FROM ANY CAUSE OR THEORY. AUTHORIZED RESELLERS ARE NOT
AUTHORIZED TO EXTEND ANY DIFFERENT WARRANTY ON FLUKE’S BEHALF. Since some states do
not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this
limitation of liability may not apply to you. If any provision of this warranty is held invalid or unenforceable by
a court or other decision-maker of competent jurisdiction, such holding will not affect the validity or
enforceability of any other provision.
Fluke Corporation Fluke Europe B.V.
P.O. Box 9090 P.O. Box 1186
Everett WA 5602 B.D. Eindhoven
2/02 98206-9090 The Netherlands
i
Table of Contents
Title Page
Introduction........................................................................................................ 1
Contacting Fluke................................................................................................ 1
Precautions and Safety Information................................................................... 2
Electrical Symbols ............................................................................................. 4
Specifications..................................................................................................... 4
General Specifications................................................................................... 4
Detailed Specifications.................................................................................. 5
Basic Maintenance ............................................................................................. 9
Cleaning the Meter ........................................................................................ 9
Opening the Meter Case ................................................................................ 9
Accessing the PCA and Replacing the LCD ................................................. 10
Reassembling the Meter Case........................................................................ 11
Replacing the Battery .................................................................................... 12
Testing Fuses and Current Circuitry.............................................................. 12
Replacing the Fuses....................................................................................... 13
Required Equipment .......................................................................................... 13
Performance Tests.............................................................................................. 14
Basic Operability Tests.................................................................................. 15
Testing the Fuses ........................................................................................... 15
Testing the Display........................................................................................ 15
Testing the Pushbuttons................................................................................. 17
Testing Meter Accuracy ................................................................................ 17
Testing the Inductive Pickup (88 Only) ........................................................ 19
Calibration Adjustment...................................................................................... 23
Calibration Adjustment Counter.................................................................... 23
Calibration Adjustment Password ................................................................. 23
Changing the Password............................................................................. 23
Restoring the Default Password ................................................................ 24
Meter Buttons Used in the Calibration Steps ................................................ 25
Calibration Adjustment Procedure ................................................................ 25
Service and Parts................................................................................................ 27


Specyfikacje produktu

Marka: Fluke
Kategoria: multimetr
Model: 87V

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Fluke 87V, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje multimetr Fluke

Fluke

Fluke 283 FC Instrukcja

9 Października 2024
Fluke

Fluke 325 Instrukcja

2 Października 2024
Fluke

Fluke 111 Instrukcja

24 Września 2024
Fluke

Fluke a3002 FC Instrukcja

23 Września 2024
Fluke

Fluke 117 Instrukcja

23 Września 2024
Fluke

Fluke 110 Instrukcja

23 Września 2024
Fluke

Fluke 83 V Instrukcja

23 Września 2024
Fluke

Fluke 115C Instrukcja

22 Września 2024
Fluke

Fluke 80 Series V Instrukcja

22 Września 2024
Fluke

Fluke 77 Series IV Instrukcja

21 Września 2024

Instrukcje multimetr

Najnowsze instrukcje dla multimetr

Voltcraft

Voltcraft PMM 3005-20 Instrukcja

9 Października 2024
Bearware

Bearware 306998 Instrukcja

9 Października 2024
Bearware

Bearware 307001 Instrukcja

9 Października 2024
Noyafa

Noyafa NF-5330C Instrukcja

9 Października 2024
Noyafa

Noyafa NF-5310B Instrukcja

9 Października 2024
Emos

Emos M3216 Instrukcja

8 Października 2024
Uni-T

Uni-T UT121B Instrukcja

7 Października 2024
Maxwell

Maxwell MX-25103 Instrukcja

6 Października 2024
Velleman

Velleman DVM840 Instrukcja

5 Października 2024
Velleman

Velleman DVM852 Instrukcja

5 Października 2024