Instrukcja obsługi Fluke 73

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Fluke 73 (12 stron) w kategorii Multimeter. Ta instrukcja była pomocna dla 5 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/12
®
73
Series III Multimeter
Instruction Sheet
Read First: Safety Information
W To avoid damage to the meter, electric shock or injury:
Never use the meter if the meter or test leads look damaged.
Be sure the test leads and rotary switch are in the correct
position for the desired measurement.
Never measure resistance in a circuit when power is applied.
Never touch the probes to a voltage source when the test
leads are plugged into the 10 A or 300 mA input jack.
Never use the meter on circuits that exceed 4800 volt-amps.
Never apply more than the rated voltage between any input
jack and earth ground.
Be careful when working with voltages above 60 V dc or 30 V
ac rms. Such voltages pose a shock hazard.
Keep your fingers behind the finger guards on the test probes
when making measurements.
W Warning
To avoid false readings, which could lead to possible
electric shock or personal injury, replace the battery
as soon as the low battery indicator (M) appears.
Symbols
WCaution: Important Information. See instruction sheet.
MAN Manual Range.
TDouble Insulation.
MLow battery. Replace battery.
CAT II Overvoltage Installation Category per IEC 61010-1-95.
CAT II instruments protect against transients from
equipment supplied from the fixed installation, e.g., TV,
PC, and household appliances.
PN 1646063 February 2002 (English)
1 97, 1 98 00 F uke o p rat on. r ht r se e . r nt d n9 9 , 2 2 l C r o i All ig s e rv d P i e i China.
Terminals
300
mA
10A
FUSED
600V CAT
V
COM
Milliamps
Amps
Volts, Ohms, Diode Test
Common Terminal
hr2f.eps
See Specifications for overload protection.
Pushbutton
Use the pushbutton to either select a fixed range or put the meter
in the Automatic Touch Hold mode.
Autorange
The meter defaults to autorange when first turned on.
Manual Range
Manual ranging is available in V ac, V dc, ohms, A ac, and A dc.
The manual range mode and Touch Hold mode are mutually
exclusive. is displayed when the meter is in the manualMAN
range mode.
Momentary
+_
V
MAN
hr14f.eps
To return to autorange, press for 1 second or change theR
measurement function.
Automatic Touch Hold Mode
W Warning
To avoid electric shock, do not use the Touch Hold
mode to determine if a circuit with high voltage is
dead. The Touch Hold mode will not capture
unstable or noisy readings.
The Touch Hold mode automatically captures and displays stable
readings. Press for 2 seconds. RHOLD is displayed when
the meter is in the Touch Hold mode.
2 seconds
+_
V DC V DC
_+_
single
beep
V V V
HOLD HOLD
V DC
HOLD
hr3f.eps
When the meter captures a new input, it beeps and a new
reading is displayed.
Note
Stray voltages can produce a new reading.
To exit the Touch Hold mode, press R or change the
measurement function. The Touch Hold mode and manual range
mode are mutually exclusive.
Bar Graph
The bar graph shows readings relative to the full scale value of a
displayed measurement range and indicates polarity.
hr16f.eps

Specyfikacje produktu

Marka: Fluke
Kategoria: Multimeter
Model: 73

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Fluke 73, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Multimeter Fluke

Fluke

Fluke 73 Instrukcja

30 Sierpnia 2024
Fluke

Fluke 175 Instrukcja

28 Sierpnia 2024
Fluke

Fluke 279 FC Instrukcja

24 Sierpnia 2024
Fluke

Fluke 28 II Ex Instrukcja

22 Sierpnia 2024
Fluke

Fluke 87V Instrukcja

22 Sierpnia 2024
Fluke

Fluke 289 Instrukcja

20 Sierpnia 2024
Fluke

Fluke a3001 FC Instrukcja

9 Sierpnia 2024
Fluke

Fluke 772 Instrukcja

8 Sierpnia 2024
Fluke

Fluke 177 Instrukcja

7 Sierpnia 2024
Fluke

Fluke T150 Instrukcja

5 Lipca 2024

Instrukcje Multimeter

Najnowsze instrukcje dla Multimeter