Instrukcja obsługi Extron ACP VC1 D


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Extron ACP VC1 D (8 stron) w kategorii Niesklasyfikowane. Ta instrukcja była pomocna dla 4 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/8
1
IMPORTANT:
Go to www.extron.com for the
complete user guide, installation
instructions, and specifications.
ACP VC1 D • Setup Guide
The Extron ACP VC1 D Audio Control Panel is a fully congurable control interface for use with any Extron ACP-enabled device.
Each ACP VC1 D includes two ACP ports, which support power and communication between the host device and the
ACP VC1 D. Up to eight ACP panels can be used per host device for more demanding control needs.
Planning System Installation
When planning an ACP system installation, consider how many ACP panels to use, maximum cable distance, and mounting (see
the ACP VC1 D product page at www.extron.com for more information regarding the ACP VC1 D).
MUTE
VO
L
U
ME
+V
ACP
PWR LOAD = 1.5W
+S -S G +V +S -S G
STAT US
GREEN
AMBER
RED
LINK
COM ERROR
ID ERROR
A
B
C
D
E
F
Figure 1. ACP VC1 D
A Front Panel Rotary Volume Knob D Connection Status LED
B Front Panel Mute Button E Reset Button
C ACP Ports (2) F Bus ID DIP Switches
Installation
Step 1: Get Ready
Use the following checklist to prepare for installation:
Download and install the latest software, rmware, and device drivers needed to congure the host device and the
connected ACP devices (see the host device user guide, available at www.extron.com, for details regarding software and
drivers).
Obtain cables, mounting hardware, and any other supplies required for the installation.
2
ACP VC1 D • Setup Guide (Continued)
Step 2: Prepare the Installation Site
ATTENTION:
Installation and service must be performed by authorized personnel only.
L’installation et l’entretien doivent être effectués par le personnel autorisé uniquement.
Extron recommends installing the ACP VC1 D into a grounded, UL Listed electrical junction box.
Extron recommande d’installer l’ACP VC1 D dans une boîte de dérivation électrique mise à la terre, certiée UL.
If the ACP VC1 D will be installed into ne furniture, it is best to hire a licensed, bonded craftsperson to cut the access
hole and perform the physical installation so the surface will not be damaged.
S’il est prévu d’installer l’ACP VC1 D dans du beau mobilier, il est préférable de faire appel à un artisan autorisé et
qualié pour couper le trou d’accès et réaliser l’installation de telle façon que la surface ne soit pas endommagée.
Follow all national and local building and electrical codes that apply to the installation site.
Respectez tous les codes électriques et dutiment, nationaux et locaux, qui s’appliquent au site de l’installation.
NOTE: For the installation to meet UL requirements and comply with National Electrical Code (NEC), the ACP VC1 D must
be installed in a UL Listed junction box. The end user or installer must furnish the junction box. It is not included with the
ACPVC1 D.
Americans with Disabilities Act (ADA) Compliance
When planning where to install these devices, consider factors affecting accessibility of the button panel such as height from
the oor, distance from obstructions, and how far a user must reach to press the buttons. For guidelines, see sections 307
(“Protruding Objects”) and 308 (“Reach Ranges”) of the 2010 available at ADA Standards for Accessible Design
http://www.ada.gov/regs2010/2010ADAStandards/2010ADAStandards.pdf.
Site Preparation
Extron offers an assortment of mud rings, optional ULListed in-wall junction boxes, external wall boxes (EWBs), and surface or
tabletop mounting boxes for use with the ACP button panels. The ACP VC1 D is a US 1-gang size device.
Step 3: Removing the Plastic Faceplate, Removing the Button Panel, and Changing the Button
The plastic faceplate and button can be replaced. Additional
buttons ship with the device and others can be ordered from
www.extron.com.
To change the button:
1. Remove the two screws holding the plastic faceplate to the
metal mounting plate and separate the faceplate from the
button plate (see 1 in the figure to the right).
2. Insert a small flat-bladed screw driver into the notch at the top
of the button plate. Release the catch holding the button plate
to the metal mounting plate (2).
3. Repeat step 2 to release the catch at the bottom of the plate.
4. Tilt the top of the button plate forward as it is removed to
prevent the button from falling out.
ACP VC1 D
Faceplate
1
2
3
5. To remove the button, press the button backward through its slot in the button
plate until the membrane containing the button is free (see 1 in the figure to the
right).
6. To replace the button, align the two pegs in the button membrane with the
holes located at opposite corners of the empty slot on the back of the button
faceplate and push the button forward so it fits in the slot (
2). Ensure the
button text orientation is correct.
7. Align the button plate with the metal mounting plate using the pegs on the rear
of the button plate as guides.
8. Snap the button plate into place.
9. Reattach the plastic faceplate using the two screws removed in step 1 on the
previous page.
Step 4: Set Bus ID Address
Set the bus identication (bus ID) DIP switches for the ACP VC1 D and any other
ACP panels being connected to the system. Each ACP device must have a unique
bus ID. If multiple panels have the same bus ID, address conicts may cause one
or more of the panels to not be recognized in DSP Congurator or by the
host device. Up to eight ACP devices can be connected in the same system.
+VG
+S-S+VG
+S-S
ACP
WR LOAD = 1.5W
S USTAT
GREEN
AMBER
RED
LINK
COM ERROR
ID ERROR
+
V+
S G
S
010010
ON
1 2 3 4 5 6
000001
1
ON
1 2 3 4 5 6
18
Unit address
DIP switches
Binary address ACP port on a
DMP 128 Plus, or
on another ACP
endpoint
ACP Ports
• Connect up to eight (8) ACP endpoint devices per
DMP 128 Plus.
• Wire the connectors the same at both ends.
• These ports are identical. You can connect devices
interchangeablly to either port.
• Do not exceed a total of 1000 feet (305meters) of cable for
connections between the DMP 128 Plus and all of the ACP
panels.
• Power is provided by the IPCP Pro, a PS 1220EB power
inserter, or an Extron 12 VDC power supply.
Bus ID Address DIP Switches
• Use these DIP switches to set the six-bit, binary
bus address for the ACP 100.
• Each ACP connected to the same DMP 128 Plus
must have a address.unique
• Switch 1 (on the left) is the highest value (32, the
the most signicant bit [labeled “MSB”]).
• Switch 6 (on the right) is the lowest (1, the least
signicant bit [labeled “LSB”]).
= on = 1, = off = 0Up Down
Examples:
2
MUTE
1


Specyfikacje produktu

Marka: Extron
Kategoria: Niesklasyfikowane
Model: ACP VC1 D

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Extron ACP VC1 D, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Extron

Extron

Extron FOX Matrix 7200 Instrukcja

9 Października 2024
Extron

Extron EWB 210 Series Instrukcja

9 Października 2024
Extron

Extron EDID 101D Instrukcja

9 Października 2024
Extron

Extron FMR 206 Instrukcja

9 Października 2024
Extron

Extron EWB Series Instrukcja

9 Października 2024
Extron

Extron IR Sensor Instrukcja

9 Października 2024
Extron

Extron AVEdge 100 Instrukcja

9 Października 2024
Extron

Extron MLM 100 AAP Instrukcja

9 Października 2024
Extron

Extron MAAP 100 Instrukcja

9 Października 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024