The Extron ACP 106 EU/MK Audio Control Panels are fully congurable control interfaces for use with any Extron ACP-enabled
device.
Each ACP 106 EU/MK includes two ACP ports, which support power and communication between the host device and the
ACP 106 EU/MK. Up to eight ACP panels can be used per host device for more demanding control needs.
NOTE: The ACP 106 EU front and rear panels are identical to those of the ACP 106 MK. The only difference is the shape of
the plastic faceplate attached to the front of the device. The panels function identically.
Front Panel Features
VOLUME
MUTE
1
0
PROGRAM
MIC
E
A
C
B
D
Extron
F
Figure 1. ACP 106 EU Front Panel
Planning the System and Installation
When planning to install an ACP system, consider how many ACP panels to use, maximum cable distance, and mounting (see
the ACP 106 EU and ACP 106 MK product pages at www.extron.com for more information about the ACP 106 EU/MK).
Installation
Step 1: Get Ready
Use the following checklist to prepare for the installation:
Download and install the latest version of software, rmware, and device drivers needed to congure the host device and
congure the connected ACP products (see the host device user guide, available on www.extron.com, for details on
software and drivers).
Obtain cables, mounting hardware, and any other supplies required for ACP 106 EU and MK installation.
Figure 2. ACP 106 EU Rear Panel
+V
ACP
PWR LOAD
= 1.5W
+S -S G +V S - G
R
STATUS
GREEN
AMBER
RED
LINK
COM ERROR
ID ERROR
A
BC
D
Rear Panel Features
A ACP Ports (2)
B Connection Status LED
C Reset Button
D Bus ID DIP Switches
A Mute Buttons
B Transmit LED
C Volume Buttons
D Volume LED Meter
E Function Button 1
F Function Button 2
2
ACP 106 EU/MK • Setup Guide (Continued)
Step 2: Prepare the Installation Site
ATTENTION:
Installation and service must be performed by authorized personnel only.
L’installation et l’entretien doivent être effectués par le personnel autorisé uniquement.
Extron recommends installing the ACP 106 EU/MK into a grounded, UL Listed electrical junction box.
Extron recommande d’installer le ACP 106 EU/MK dans un boîtier d’encastrement électrique mis à la terre, listé UL.
If the ACP 106 EU/MK will be installed into ne furniture, it is best to hire a licensed, bonded craftsperson to cut the
access hole and perform the physical installation so the surface will not be damaged.
S’il est prévu d’installer le ACP 106 EU/MK dans du beau mobilier, il est préférable de faire appel à un artisan autorisé et
qualié pour couper le trou d’accès et réaliser l’installation de telle façon que la surface ne soit pas endommagée.
Follow all national and local building and electrical codes that apply to the installation site.
Respectez tous les codes électriques et du bâtiment, nationaux et locaux, qui s’appliquent au site de l’installation.
NOTE: For the installation to meet UL requirements and to comply with National Electrical Code (NEC), the ACP 106 EU/MK
must be installed in a UL Listed junction box. The end user or installer must furnish the junction box. It is not included with
the ACP106 D.
Americans with Disabilities ACT (ADA) Compliance
When planning where to install these devices, consider factors affecting accessibility of the button panel such as height
from the oor, distance from obstructions, and how far a user must reach to press the buttons. For guidelines, see sections
307 (“Protruding Objects”) and 308 (“Reach Ranges”) of the available at 2010 ADA Standards for Accessible Design
http://www.ada.gov/regs2010/2010ADAStandards/2010ADAStandards.pdf.
Site Preparation
Extron offers an assortment of mud rings, optional ULListed in-wall junction boxes, external wall boxes (EWBs), and surface or
tabletop mounting boxes for use with the ACP button panels. The ACP 106 EU and ACP 106 MK are 1-gang EU and MK size
devices.
Step 3: Removing the Plastic Faceplate, Button Panel, and Changing
the Buttons
The plastic faceplate and buttons can be replaced. Additional buttons ship with the device and
others can be ordered from www.extron.com.
To change the buttons:
1. Insert the Extron removal tool (pry tool) between one side of the plastic faceplate and the
button plate. Release the catch holding the wallplate to the metal mounting plate (see 1
in the gure to the right). If necessary, use the pry tool to release the second catch on the
opposite side.
2. To separate the button plate from the control plate, insert a small at-bladed screw driver
into one of the slots (see 2 in the gure at the bottom of the page).
3. Press the blade of the screw driver in until there is an audible
click and the tab is pushed out of the slot.
4. Repeat steps 2 and 3 to release all four tabs holding the button
plate in place.
5. Tilt the top of the button plate forward as it is removed to
prevent the buttons from falling out (3).
VOLUME
MUTE
2
3
X
MIC
PROGRAM
VOLUME
MUTE
MIC
PROGRAM
X
Extr onExtr on
Insert
to lin
e.
1
3
6. To remove a button, press a button backward through its slot in the button plate until the
membrane containing the button is free.
7. To replace a button, align the two pegs in the button membrane with the holes located at
opposite corners of the empty slot on the back of the button faceplate and push the button
forward so it ts in the desired slot (see the gure to the right). Ensure the button text
orientation is correct.
8. Press the button into the button plate until the pegs on the membrane are seated in the
corresponding holes.
9. Repeat steps 6 through 8 for any other buttons being replaced.
10. Align the back of the button plate with the control plate and press it into place. The four
tabs released in steps 2 through 4 snap back into place.
11. Ensure the plastic faceplate and metal mounting plate are in the correct orientation. To reattach the plastic faceplate, press
the faceplate back into the metal mounting plate, using the two catches released in step 1.
Step 4: Set Bus ID Addresses
ACP
+S -S G+V +V +S -S G
R
PWR LOAD
= 1.5W
ST USAT
GREEN
AMBER
RED
LINK
COM ERROR
ID ERROR
+
V+
S G
S
0 1 0 0 1 0
ON
1 2 3 4 5 6
0 0 0 0 0 1
1
ON
1 2 3 4 5 6
18Unit address
DIP switches
Binary address
ACP port on a
DMP Plus, or on
another ACP
endpoint
ACP Ports
Connect up to eight (8) ACP endpoint devices per
DMP Plus.
Wi the connectors the same at both ends.re
These ports a identical. You can connect devices re
interchangeably to either port.
Do not exceed a total of 1000 feet (305meters) of cable for
connections between the DMP Plus and all of the ACP
panels.
Power is provided by the DMP Plus, a PS 1220EB power
inserter, or an Extron 12 VDC power supply.
Bus ID Address DIP Switches
Use these DIP switches to set the six-bit, binary
bus address for the ACP 106 EU/MK.
Each ACP connected to the same DMP Plus
must have a address.unique
Switch 1 (on the left) is the highest value (32, the
the most signicant bit [labeled “MSB”]).
Switch 6 (on the right) is the lowest (1, the least
signicant bit [labeled “LSB”]).
= on = 1, = off = 0Up Down
Examples:
Figure 3. ACP 106 EU/MK Rear Panel and Bus ID DIP Switch Assembly
Set the bus identication (bus ID) DIP switches for the ACP 106 EU/MK and
any other ACP panels being connected to the system. Each ACP device
must have a unique bus ID. If multiple panels have the same bus ID, address
conicts may cause one or more of the panels to not be recognized in DSP
Congurator or by the host device. Up to eight ACP devices can be connected
in the same system.
Each ACP device in a system must have a unique six-digit binary bus ID. ACP
bus IDs are set using the DIP switch assembly on the rear panel of the ACP
106 EU/MK (see gure 3).
Switch 1 on the left sets the most signicant bit (highest number, 32) while
switch 6 on the right sets the least signicant bit (the lowest number, 1). See
the example addresses to the right.
Slide
1 2 3 4 5 6
ON
M
S
B
L
S
B
BUS ID
Example Addresses
Bus ID
(Decimal)
Binary
Address
DIP Switch
Setting
0 000000*
1 2 3 4 5 6
ON
M
S
B
L
S
B
1 000001
1 2 3 4 5 6
ON
M
S
B
L
S
B
2 000010
1 2 3 4 5 6
ON
M
S
B
L
S
B
3 000011
1 2 3 4 5 6
ON
M
S
B
L
S
B
4 000100
1 2 3 4 5 6
ON
M
S
B
L
S
B
5 000101
1 2 3 4 5 6
ON
M
S
B
L
S
B
6 000110
1 2 3 4 5 6
ON
M
S
B
L
S
B
7 000111
1 2 3 4 5 6
ON
M
S
B
L
S
B
8 001000
1 2 3 4 5 6
ON
M
S
B
L
S
B
*Address 000000 is reserved for the control processor and cannot be used by any ACP devices.


Specyfikacje produktu

Marka: Extron
Kategoria: Niesklasyfikowane
Model: ACP 106 EU

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Extron ACP 106 EU, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Extron

Extron

Extron FOX Matrix 7200 Instrukcja

9 Października 2024
Extron

Extron EWB 210 Series Instrukcja

9 Października 2024
Extron

Extron EDID 101D Instrukcja

9 Października 2024
Extron

Extron FMR 206 Instrukcja

9 Października 2024
Extron

Extron EWB Series Instrukcja

9 Października 2024
Extron

Extron IR Sensor Instrukcja

9 Października 2024
Extron

Extron AVEdge 100 Instrukcja

9 Października 2024
Extron

Extron MLM 100 AAP Instrukcja

9 Października 2024
Extron

Extron MAAP 100 Instrukcja

9 Października 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024