Congratulations on your purchase of the Extech EX230 Autoranging Multimeter. This meter measures
AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency, Duty Cycle, Diode Test, and
Continuity plus non-contact InfraRed Temperature and contact thermocouple Temperature. Proper use
and care of this meter will provide many years of reliable service.
Safety
This symbol adjacent to another symbol, terminal or operating device indicates
that the operator must refer to an explanation in the Operating Instructions to
avoid personal injury or damage to the meter.
This WARNING symbol indicates a potentially hazardous situation, which if not
avoided, could result in death or serious injury.
This CAUTION symbol indicates a potentially hazardous situation, which if not
avoided, may result damage to the product.
This symbol advises the user that the terminal(s) so marked must not be
connected to a circuit point at which the voltage with respect to earth ground
exceeds (in this case) 600 VAC or VDC.
This symbol adjacent to one or more terminals identifies them as being associated
with ranges that may, in normal use, be subjected to particularly hazardous
voltages. For maximum safety, the meter and its test leads should not be handled
when these terminals are energized.
This symbol indicates that a device is protected throughout by double insulation or
reinforced insulation.
PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY
OVERVOLTAGE CATEGORY I
Equipment of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which
measures are taken to limit the transient overvoltages to an appropriate low level.
Note – Examples include protected electronic circuits.
OVERVOLTAGE CATEGORY II
Equipment of OVERVOLTAGE CATEGORY II is energy-consuming equipment to be supplied from
the fixed installation.
Note – Examples include household, office, and laboratory appliances.
OVERVOLTAGE CATEGORY III
Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations.
Note Examples include switches in the fixed installation and some equipment for industrial use
with permanent connection to the fixed installation.
OVERVOLTAGE CATEGORY IV
Equipment of OVERVOLTAGE CATEGORY IV is for use at the origin of the installation.
Note – Examples include electricity meters and primary over-current protection equipment
WARNING
CAUTION
MAX
600V
EX230-en-GB_1.4 4/15 3
CAUTIONS
Improper use of this meter can cause damage, shock, injury or death. Read and understand
this user manual before operating the meter.
Always remove the test leads before replacing the battery or fuses.
Inspect the condition of the test leads and the meter itself for any damage before operating the
meter.
Use great care when making measurements if the voltages are greater than 25 VAC rms or 35
VDC. These voltages are considered a shock hazard.
Warning! This is a Class A device. This dev
ice can cause interference in residential areas.
Always discharge capacitors and remove power
from the device under test before performing
Diode, Resistance or Continuity tests.
Voltage checks on electrical outlets can be di
fficult and misleading because of the uncertainty
of connection to the recessed electrical contacts. Other means should be used to ensure that
the terminals are not "live".
If the equipment is used in a manner not specified by the manufacturer, the protection provided
by the equipment may be impaired.
This device must not be used by children. It contains hazardous objects
as well as small parts
that the children could swallow.
Do not leave batteries and packing material
lying around unattended; they can be dangerous
to children.
In the event that this device will be stored fo
r an extended period of time, remove the batteries.
Expired or damaged batteries can be hazardous to skin. Use suitable hand gloves in such
cases.
Do not short-circuit the battery. Do not place the battery near a fire.

Specyfikacje produktu

Marka: Extech
Kategoria: Multimeter
Model: EX230

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Extech EX230, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Multimeter Extech

Extech

Extech Ex 810 Instrukcja

14 Września 2024
Extech

Extech MN24 Instrukcja

30 Sierpnia 2024
Extech

Extech MA445 Instrukcja

26 Sierpnia 2024
Extech

Extech 382213 Instrukcja

25 Sierpnia 2024
Extech

Extech EX613 Instrukcja

24 Sierpnia 2024
Extech

Extech DVA30 Instrukcja

18 Sierpnia 2024
Extech

Extech EX503 Instrukcja

16 Sierpnia 2024
Extech

Extech EX430A Instrukcja

14 Sierpnia 2024
Extech

Extech EX830 Instrukcja

13 Sierpnia 2024
Extech

Extech MN26 Instrukcja

6 Sierpnia 2024

Instrukcje Multimeter

Najnowsze instrukcje dla Multimeter