Plumber's Putty
Groove joint pliers
SAVE FOR CONSUMER
Screwdriver
Wrench (2) 1/2 in Supply Lines Sealant Tape
OPTIONAL 2.2GPM FLOW
REGULATOR
INSTALLATION / OWNER'S MANUAL
Model # LKEC2012
Single Handle Bar Faucet
You choose the flow rate!
This faucet ships with an
eco-friendly 1.5GPM flow regulator
installed.
If you desire higher flow rate, a
2.2GPM flow regulator has also
been included in the box.
Switching the flow regulator is
simple! See the "Flow Regulator
Replacement" section for details.
Important!
WARNING: Please carefully read and properly follow the instructions for installation found in this manual.
From underneath the sink,align block
and tabs on quick connects.Push quick
connect housing firmly upward and snap
onto receiving block.Pull down moderately
to ensure connection has been made. If it
is necessary to remove quick connect,
squeeze tabs on hose between index
finger and thumb, then pull down to
disconnect.
1
Important: after installation is completed,
turn on hot and cold water supplies.
Remove aerator . Turn faucet handle to
the warm position where it mixes hot and
cold water. Flush water lines for one
minute. Check for leaks.Retighten any
connections if necessary.Reinstall the
aerator tightly.
1
Place faucet through the hole in top of
sink. From underside,assemble rubber
washer ,metal washer and nut ② ③
onto long shank and tighten nut . ④ ③
Firmly tighten the nut to metal washer
. Do not overtighten.
Make connections to water lines with 3/8"
female compression supply hoses .
If additional hose length is needed, attach
included 1/2" MIP thread adaptors to
supply hoses . Use 1/2" I.P.S. faucet
connections or coupling nuts with 3/8" ③ ⑤
O.D.ball-nose riser to make connections
to water lines. Use wrenches to tighten
connections. Do not overtighten.
3
2
5
4
Shut off water supplies.Clean sink surface.
Place washer and flange on the sink② ①
.If you do not use flange,please use
escutcheon and gasket to replace ④ ⑤
flange and washer.
1
3
2
1
STEPS:
Ø 1 3/8''
Ø35mm
4
5
1
2
3
4
2
FOR CARE AND MAINTENANCE:
·The water in certain areas of the world can be very caustic -
standing water around the product can cause damage. Be
sure to remove standing water with a dry, soft cloth as soon
as possible.
·For polished brass finishes, as often as once a week, you
can apply a paste wax or special, non-abrasive, brass
coating (DO NOT APPLY POLISH).
·Before applying a protective coating, gently brush the entire
fixture using a soft tooth brush. This will remove any dirt or
deposit build-up.
·These simple steps will add temporary protective coating to
your faucet and extend the life of the finish.
Failure to follow care and cleaning will void your warranty.
For additional information, please visit elkayusa.com .
CARE AND CLEANING INSTRUCTIONS
Loosen cartridge nut by turning it counter-clockwise and
lift out the cartridge .Remove old cartridge and replace
with new cartridge. Reinstall the handle.
The faucet ships with a 1.5GPM aerator installed. An
optional 2.2 GPM aerator is also included in the box.
To switch the flow rate of the faucet:
1. Disassemble the quick connect assembly by
separating the connector and quick connect . ① ②
2. Replace 1.5 GPM connector(green) with the 2.2GPM
connector.
3. Reinstall quick connect assembly.
Congratulations on your purchase of an Elkay product.
Although your product is extremely durable, attention should
be given to the care, cleaning and maintenance of this
product. Cleaning agents and abrasives may cause damage,
which may result in oxidation and discoloration.
By following these simple guidelines for proper care and
cleaning, it will give you years of enjoyment:
TO CLEAN: Simply wipe gently with a damp cloth and blot dry
with a soft towel. A common rule of thumb is: when you dry off,
dry off your product.
· Avoid build-up of soap, toothpaste or mineral deposits, as
these tend to have an adverse effect on the appearance of
the product.
· NEVER use cleaning products of any kind on this product -
especially those containing ammonia, bleach or alcohol - or
those with any form of abrasive.
Shut off water supply! .With valves in "closed" position,
unscrew set screw and remove handle from valve stem ⑥ ⑤
. Loosen the screw from valve stem . Loosen the cap ③ ②
from the cartridge nut .
FLOW REGULATOR REPLACEMENT
2
1
1
2
1
6
CARTRIDGE REPLACEMENT
21 3 4 5
2 1


Specyfikacje produktu

Marka: Elkay
Kategoria: Dźwig
Model: LKEC2012LS

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Elkay LKEC2012LS, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Dźwig Elkay

Elkay

Elkay LKSS1141A Instrukcja

8 Października 2024
Elkay

Elkay LKSSVR1141A Instrukcja

8 Października 2024
Elkay

Elkay LK1141A Instrukcja

8 Października 2024
Elkay

Elkay LK109A Instrukcja

8 Października 2024
Elkay

Elkay LKBH1141A Instrukcja

8 Października 2024
Elkay

Elkay LKVRBH1141A Instrukcja

8 Października 2024
Elkay

Elkay LKVR1141A Instrukcja

8 Października 2024
Elkay

Elkay LKEC2037CR Instrukcja

22 Września 2024
Elkay

Elkay LKEC2031LS Instrukcja

21 Września 2024
Elkay

Elkay LKHA1041CR Instrukcja

21 Września 2024

Instrukcje Dźwig

Najnowsze instrukcje dla Dźwig