Instrukcja obsługi Daikin FTXS35G


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Daikin FTXS35G (14 stron) w kategorii klimatyzacja. Ta instrukcja była pomocna dla 9 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/14
R410A Split Series
INSTALLATION MANUAL
DAIKIN ROOM AIR CONDITIONER
EnglishDeutschFrançaisNederlandsEspañolItaliano
ΕλληνικÜ
Portugues
Рóссêий
Türkçe
Installation manual
Installationsanleitung
Manuel d’installation
Montagehandleiding
Manual de instalación
Manuale d’installazione
Manual de Instalação
MODELS
FTXS60GV1B
FTXS71GV1B
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-ku, Osaka, 530-8323 Japan
DAIKIN INDUSTRIES, LTD.
Low Voltage 2006/95/EC
Electromagnetic Compatibility 2004/108/EC
*
3SB64526-10B
Shinri Sada
Manager Quality Control Department
1st. of Sep. 2009
DAIKIN.TCF.015 M11/08-2009
FTXS60GV1B, FTXS71GV1B
KEMA Quality B.V.
74736-KRQ/EMC97-4957
1English
Safety Precautions
The precautions described herein are classified as WARNING and CAUTION. They both contain important
information regarding safety. Be sure to observe all precautions without fail.
Meaning of WARNING and CAUTION notices
WARNING ....Failure to follow these instructions properly may result in personal injury or loss of life.
CAUTION ..... Failure to observe these instructions properly may result in property damage or personal injury, which
may be serious depending on the circumstances.
The safety marks shown in this manual have the following meanings:
After completing installation, conduct a trial operation to check for faults and explain to the customer how to operate
the air conditioner and take care of it with the aid of the operation manual.
Be sure to follow the instructions. Be sure to establish an earth connection. Never attempt.
WARNING
Ask your dealer or qualified personnel to carry out installation work.
Do not attempt to install the air conditioner yourself. Improper installation may result in water leakage, electric shocks or fire.
Install the air conditioner in accordance with the instructions in this installation manual.
Improper installation may result in water leakage, electric shocks or fire.
Be sure to use only the specified accessories and parts for installation work.
Failure to use the specified parts may result in the unit falling, water leakage, electric shocks or fire.
Install the air conditioner on a foundation strong enough to withstand the weight of the unit.
A foundation of insufficient strength may result in the equipment falling and causing injury.
Electrical work must be performed in accordance with relevant local and national regulations and with instructions
in this installation manual. Be sure to use a dedicated power supply circuit only.
Insufficiency of power circuit capacity and improper workmanship may result in electric shocks or fire.
Use a cable of suitable length.
Do not use tapped wires or an extension lead, as this may cause overheating, electric shocks or fire.
Make sure that all wiring is secured, the specified wires are used, and that there is no strain on the terminal
connections or wires.
Improper connections or securing of wires may result in abnormal heat build-up or fire.
When wiring the power supply and connecting the wiring between the indoor and outdoor units, position the wires
so that the control box lid can be securely fastened.
Improper positioning of the control box lid may result in electric shocks, fire or over heating terminals.
If refrigerant gas leaks during installation, ventilate the area immediately.
Toxic gas may be produced if the refrigerant comes into contact with fire.
After completing installation, check for refrigerant gas leakage.
Toxic gas may be produced if the refrigerant gas leaks into the room and comes into contact with a source of fire, such as a fan heater, stove or cooker.
When installing or relocating the air conditioner, be sure to bleed the refrigerant circuit to ensure it is free of air, and
use only the specified refrigerant (R410A).
The presence of air or other foreign matter in the refrigerant circuit causes abnormal pressure rise, which may result in equipment damage and even injury.
During installation, attach the refrigerant piping securely before running the compressor.
If the compressor is not attached and the stop valve is open when the compressor is run, air will be sucked in, causing abnormal pressure in
the refrigeration cycle, which may result in equipment damage and even injury.
During pump-down, stop the compressor before removing the refrigerant piping.
If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the refrigerant piping is removed,
causing abnormal pressure in the refrigeration cycle, which may result in equipment damage and even injury.
Be sure to earth the air conditioner.
Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead. Imperfect earthing may result in electric shocks.
Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in electric shocks or fire.
CAUTION
Do not install the air conditioner at any place where there is a danger of flammable gas leakage.
In the event of a gas leakage, build-up of gas near the air conditioner may cause a fire to break out.
While following the instructions in this installation manual, install drain piping to ensure proper drainage and
insulate piping to prevent condensation.
Improper drain piping may result in indoor water leakage and property damage.
Tighten the flare nut according to the specified method such as with a torque wrench.
If the flare nut is too tight, it may crack after prolonged use, causing refrigerant leakage.


Specyfikacje produktu

Marka: Daikin
Kategoria: klimatyzacja
Model: FTXS35G
Kolor produktu: Biały
Częstotliwość wejściowa AC: 50 Hz
Napięcie wejściowe AC: 220 - 240 V
Technologia przetworników: Nie
Wi-Fi: Nie
Model: Jednostka wewnętrzna klimatyzatora
Urządzenie rozmrażające: R410A
Funkcje wentylacji: Cooling, Fan, Heating
Jonizator: Nie
Wydajność chłodzenia w watach (nominalna): - W
Nominalna moc cieplna w watach (cieplejszy sezon grzewczy): - W
Nominalna moc cieplna w watach (średni sezon grzewczy): - W
Nominalna moc cieplna w watach (chłodniejszy sezon grzewczy): - W
Godzinne zużycie energii (chłodzenie): - kWh
Godzinne zużycie energii (ogrzewanie): - kWh
Roczne zużycie energii (chłodzenie): - kWh
Roczne zużycie energii (ogrzewanie) (cieplejszy sezon grzewczy): - kWh
Roczne zużycie energii (ogrzewanie) (średni sezon grzewczy): - kWh
Roczne zużycie energii (ogrzewanie) (chłodniejszy sezon grzewczy): - kWh
Przepływ zimnego powietrza (jednostka zewnętrzna): 462 m³/h
Klasa energetyczna (chłodzenie): A
Szerokość jednostki wewnętrznej: 800 mm
Ilość jednostek wewętrznych: 1
Głębokość jednostki wewnętrznej: 215 mm
Wysokość jednostki wewnętrznej: 295 mm
Waga jednostki wewnętrznej: 10000 g
Typ jednostki wewnętrznej: Możliwość montażu ściennego
Przepływ gorącego powietrza (jednostka wewnętrzna): 510 m³/h
Szybkość wentylatora jednostki wewnętrznej (chłodzenie, duża prędkość): 1370 RPM
Szybkość wentylatora jednostki wewnętrznej (chłodzenie, średnia prędkość): 1090 RPM
Szybkość wentylatora jednostki wewnętrznej (chłodzenie, mała prędkość): 800 RPM
Szybkość wentylatora jednostki wewnętrznej (ogrzewanie, duża prędkość): 1370 RPM
Szybkość wentylatora jednostki wewnętrznej (ogrzewanie, średnia prędkość): 1160 RPM
Szybkość wentylatora jednostki wewnętrznej (ogrzewanie, niska prędkość): 940 RPM

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Daikin FTXS35G, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje klimatyzacja Daikin

Daikin

Daikin Cora FTXV95LVMA Instrukcja

13 Października 2024
Daikin

Daikin 3MXF68A2V1B9 Instrukcja

9 Października 2024
Daikin

Daikin ATXM25R2V1B Instrukcja

9 Października 2024
Daikin

Daikin ATXM35R5V1B Instrukcja

9 Października 2024
Daikin

Daikin ATXM35R2V1B Instrukcja

9 Października 2024
Daikin

Daikin ATXF35E Instrukcja

2 Października 2024
Daikin

Daikin ARXP35N Instrukcja

2 Października 2024
Daikin

Daikin ARXP25N Instrukcja

2 Października 2024
Daikin

Daikin RKM-PVM Instrukcja

23 Września 2024
Daikin

Daikin FTXC60CV1B Instrukcja

23 Września 2024

Instrukcje klimatyzacja

Najnowsze instrukcje dla klimatyzacja

LG

LG HS-H076QPA0 Instrukcja

15 Października 2024
Klarstein

Klarstein Vita Pure 2G Instrukcja

15 Października 2024
Gree

Gree ETAC-15HP265V20B Instrukcja

15 Października 2024
Qlima

Qlima P 126 Instrukcja

14 Października 2024
Mitsubishi

Mitsubishi MSZ-CB22VA Instrukcja

14 Października 2024
Suntec

Suntec Motion 90+ Instrukcja

14 Października 2024
Danby

Danby DTAC120B1WDB Instrukcja

14 Października 2024
Amana

Amana PTC093K35AXXX Instrukcja

14 Października 2024
Amana

Amana AMAP121AB-2 Instrukcja

14 Października 2024