Instrukcja obsługi Ctek MXS 15 Acculader

Ctek Ładowarka baterii MXS 15 Acculader

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Ctek MXS 15 Acculader (6 stron) w kategorii Ładowarka baterii. Ta instrukcja była pomocna dla 11 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/6
EN
EN • 3
SUPPLYNORMAL RECOND
RECOND
SUPPLY
MODE
12V/15A
MXS 15
SUPPLYNORMAL RECOND
RECOND
SUPPLY
MODE
12V/25A
MXS 25
ABSORPTION, READY TO USE
ANALYSE
SUPPLY PLUG*
L: 2000 mm
NORMAL
BATTERY
PROGRAM
ERROR LAMP
RECOND
PROGRAM
SUPPLY
PROGRAM
POWER
LAMP
CHARGING
1. Connect the charger to the battery.
2. Connect the charger to the wall socket. The power lamp will indicate that the mains
cable is connected to the wall socket. The error lamp will indicate if the battery clamps
are incorrectly connected. The reverse polarity protection will ensure that the battery
or charger will not be damaged.
3. Press the MODE-button to select charging program.
4. Follow the indication lamps through the charging process.
The battery is ready to start the engine when is lit.
The battery is fully charged when is lit.
5. Stop charging at any time by disconnecting the mains cable from the wall socket.
MODE-
BUTTON
MANUAL
DESULPHATION
SOFT START
BULK FLOAT, FULLY CHARGED
PULSE, MAINTENANCE CHARGING
TEMPERATURE
SENSOR
INDICATOR
TEMPERATURE
SENSOR
CONGRATULATIONS
to the purchase of your new professional switch mode battery
charger. This charger is included in a series of professional
chargers from CTEK SWEDEN AB and represents the latest
technology in battery charging.
MAINS CABLE
*Supply plugs may differ to suit your wall socket.
20016019B MXS 15, Manual AUS, Print file 002.indd 3 2011-10-27 10:27:07
4 • EN
BATTERY SIZE (Ah) TIME TO 80% CHARGED
40Ah 2h
100Ah 5h
200Ah 10h
300Ah 16h
READY TO USE
The table shows the estimated time for empty battery to 80% charge
CHARGING PROGRAMS
Settings are made by pressing the MODE-button. After about two seconds the charger
activates the selected program. The selected program will be restarted next time the
charger is connected.
The table explains the dierent Charging Programs:
Program Battery
Size (Ah) Explanation Temp range
NORMAL 30–500Ah
Normal battery program
14.4V/15A. Use for WET batteries,
Ca/Ca, MF and for most GEL batteries
-20°C+50°C
(-4ºF–122ºF)
RECOND 30–500Ah
Recond program 15.8V/3A
Use to return energy to the empty
WET and Ca/Ca batteries. Recond
your battery once per year and after
deep dischare to maximise lifetime and
capacity. The Recond program adds the
Recond step to the normal battery
program. Frequent use of the Recond
program may cause water loss in the
batteries and reduce service life of
electronics. Contact your vehicle and
battery supplier for advice.
-20°C+50°C
(-4ºF–122ºF)
30–500Ah
Supply program 13.6V/15A
Use as 12V power supply or use for
float maintenance charging when 100%
capacity of the battery is required.
Supply program activates Float step
without time or voltage limitation.
-20°C+50°C
(-4ºF–122ºF)
ERROR LAMP
If the error lamp is lit, check the following:
1. Is the chargers positive lead connected to the batterys
positive pole?
2. Is the charger connected to a 12V battery?
3. Has charging been interrupted in or ?
Restart the charger by pressing the MODE-button. If charging is still
being interrupted, the battery...
...is seriosly sulphated and may need to be replaced.
...can not accept charge and may need to be replaced.
...can not keep charge and may need to be replaced.
WARNING!
The spark protection on the battery charger
is disabled during SUPPLY program.
TEMPERATURE SENSOR
The MXS 15 is equipped with an external temperature sensor. Activated
temperature sensor will be indicated by a lit temperature sensor indicator
lamp. The temperature sensor will adjust the voltage to the ambient tempera-
ture. Place the temperature sensor in the positive clamp or as the close to the
battery as possible.
POWER LAMP
If the power lamp is lit with a:
1. STEADY LIGHT
The mains cable is connected to the wall socket.
2. FLASHING LIGHT:
The charger has entered the energy save mode. This happens if the
charger isn´t connected to the battery in 2 minutes.
SUPPLYNORMAL RECOND
RECOND
SUPPLY
MODE
12V/25A
MXS 25
SUPPLYNORMAL RECOND
RECOND
SUPPLY
MODE
12V/25A
MXS 25
SUPPLYNORMAL RECOND
RECOND
SUPPLY
MODE
12V/25A
MXS 25
20016019B MXS 15, Manual AUS, Print file 002.indd 4 2011-10-27 10:27:08
EN
EN • 5
STEP 1 DESULPHATION
Detects sulphated batteries. Pulsing current and voltage, removes sulphate from the lead
plates of the battery restoring the battery capacity.
STEP 2 SOFT START
Tests if the battery can accept charge. This step prevents that charging proceeds with a
defect battery.
STEP 3 BULK
Charging with maximum current until approximately 80% battery capacity.
STEP 4 ABSORPTION
Charging with declining current to maximize up to 100% battery capacity.
STEP 5 ANALYSE
Tests if the battery can hold charge. Batteries that can not hold charge may need to be replaced.
STEP 6 RECOND
Choose the Recond program to add the Recond step to the charging process. During the Recond step
voltage increases to create controlled gasing in the battery. Gasing mixes the battery acid and gives
back energy to the battery.
STEP 7 FLOAT
Maintaining the battery voltage at maximum level by providing a constant voltage charge.
STEP 8 PULSE
Maintaining the battery at 95–100% capacity. The charger monitors the battery voltage and gives a
pulse when necessary to keep the battery fully charged.
1
VOLTAGE (V)CURRENT (A)
ANALYSE RECOND PULSE
DESULPHATION SOFT START BULK ABSORPTION
14.4V 15A until 12.6V Increasing voltage
to 14.4V @ 25°C
15A
17
Limit: Max 20h Max 8h 3 minutes 30 min or 4h
depending on
battery voltage
10 days
Charge cycle restarts
if voltage drops*
Charge cycle restarts
if voltage drops
Max 4h
14.4V 15A until 12.6V Increasing voltage
to 14.4V @ 25°C
15A
14.4V @ 25°C
Declining current
14.4V @ 25°C
Declining current
Checks if voltage
drops to 12V
Checks if voltage
drops to 12V
Max 13.6V
15A
13.6V
15A
13.6V
15A
12.9V‒14.4V
18‒4.5A
12.9V‒14.4V
18‒4.5A
Max 4h
2 3 4 5
FLOAT
6 8
RECOND
SUPPLY
NORMAL
Max 15.8V
3A
CHARGING PROGRAM
*Supply program is not time or voltage limited.
20016019B MXS 15, Manual AUS, Print file 002.indd 5 2011-10-27 10:27:08


Specyfikacje produktu

Marka: Ctek
Kategoria: Ładowarka baterii
Model: MXS 15 Acculader

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Ctek MXS 15 Acculader, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Ładowarka baterii Ctek

Instrukcje Ładowarka baterii

Najnowsze instrukcje dla Ładowarka baterii

MSW

MSW S-CHARGER-20A.2 Instrukcja

15 Października 2024
MSW

MSW S-CHARGER-10A.2 Instrukcja

15 Października 2024
Intenso

Intenso Powerbank 10400 Instrukcja

14 Października 2024
Gembird

Gembird CHM-03 Instrukcja

10 Października 2024
Kostal

Kostal IQ 8.5 Instrukcja

9 Października 2024
Venom

Venom VS5007 Instrukcja

9 Października 2024
Venom

Venom VS5010 Instrukcja

9 Października 2024
Venom

Venom VS2891 Instrukcja

9 Października 2024
Venom

Venom VS2881 Instrukcja

9 Października 2024
Venom

Venom VS2883 Instrukcja

9 Października 2024