Instrukcja obsługi Crestron C2NI-AMP-4X100

Crestron przełącznik C2NI-AMP-4X100

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Crestron C2NI-AMP-4X100 (3 stron) w kategorii przełącznik. Ta instrukcja była pomocna dla 13 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/3
1
quickstart guide
C2N(I)-AMP-4X100
www.crestron.com
Specifications subject to
change without notice.
C2N(I)-AMP-4X100
For Regulatory Compliance information, refer to the latest version
of Doc. 7289.
QUICKSTART DOC. 7288B (2032394, Sheet 1 of 2) 04.13
4 Room Audio System
1
Make the necessary connections as called out in the diagram below. Connect power last.
Hardware Hookup
NOTE: SPEAKER OUTPUTS For triple the power (into 8 speakers only), 1
and 2 or 3 and 4 can be bridged. For example, the left SPEAKER OUTPUTS
speaker’s + and - terminals are connected to the two + terminals of output #1
and the right speaker’s + and - terminals are connected to the two + terminals
of output #2. Refer to the diagram to the right.
To adjust volume when bridged, select 1 for 1 ROOM SPEAKER OUTPUTS
and 2 or select 2 for 3 and 4.ROOM SPEAKER OUTPUTS
RM 1
RM 3
RM 2
RM 4
BRIDGE
8 OHMS ONLY +-
+-
L+-+-R
L+-+-R
To Cresnet Devices
NET
From AC Power Line
PWR
Tie to Ground
G
From Unbalanced Stereo Line Level Audio
Outputs from Source Devices
ANALOG SOURCES (IN)
To Additional Amplifiers
ANALOG SOURCES (OUT)
NOTE: NET The 24 volt lines on the ports of the amplifier are
limited to 300 mA.
To Loudspeakers
SPEAKER OUTPUTS
NON-BRIDGE
L+-+-R
+ - + -
LEFT RIGHT
NOTE: The C2NI-AMP-4X100 (International
version) requires a power cord that is
harmonized to the country’s national and local
electrical codes. Each inner wire in the cord
should be at least 18 AWG (0.75 mm
2) and rated
for at least 300 V. The temperature rating of the
cord should be at least 60º C. The cord length
should be 1.5 - 2 meters.
To Cresnet® Devices
LOOP THRU
2Attach the Labels
Use the included labels and inserts to prepare the C2N(I)-AMP-4X100:
1. Locate the and label inserts included with the unit ( insert has space for six labels, insert has room for four labels).SOURCE ROOM SOURCE ROOM
2. Apply the peel-and-stick labels in the appropriate positions on the inserts, being careful to match label positions to what is configured in the programming software. For neatest appearance, when applying a label,
cover the white guidelines on the insert. First and last labels cover one line each; labels in between cover lines on their left and right sides.
2
quickstart guide
C2N(I)-AMP-4X100
www.crestron.com
Specifications subject to
change without notice.
C2N(I)-AMP-4X100
For Regulatory Compliance information, refer to the latest version
of Doc. 7289.
QUICKSTART DOC. 7288B (2032394, Sheet 1 of 2) 04.13
4 Room Audio System
3Establish Communication
2
The port on the C2N(I)-AMP-4X100 connects to the control system via Cresnet:NET
1. In Crestron Toolbox, click Tools System Info| .
2. Click the icon.
3. For Connection Type Cresnet ID Through , select . In the drop-down menu, select
the control system that is connected to the device.
4. Click OK. Communications are confirmed when the device information is
displayed.
4
The Net ID of the C2N(I)-AMP-4X100 has been factory set to . The Net IDs of 33
multiple C2N(I)-AMP-4X100 devices in the same system must be unique. Net IDs are
changed from a personal computer (PC) via Crestron Toolbox (refer to “Establish
Communication” in section π).
Net ID
5
Turn the Amplifier On or Off
To turn the amplifier on, move the front panel switch to the position.ON
To turn the amplifier off, move the front panel switch to the position.OFF
Select a Source
To select a source for distribution, press the desired button. If a room is connected to the selected source, SOURCE
its LED lights.
NOTE: If a room is in Volume Control mode, press a button to exit the mode.SOURCE
Select a Room
Once a source is selected, press any button that is to receive the selected source. The room is connected to ROOM
the selected source and its LED lights.
To remove a room from the selected source, press the button of a connected room. The LED turns off.ROOM
NOTE: If a room is in Volume Control mode, press a button to exit the mode.ROOM
NOTE: ROOM 1 ROOM 2 If the outputs of the C2N(I)-AMP-4X100 are bridged, the button acts in unison with the
button and the button acts in unison with the button. Similarly, the LED acts in unison ROOM 3 ROOM 4 ROOM 1
with the LED and the LED acts in unison with the LED.ROOM 2 ROOM 3 ROOM 4
Volume Control Mode
The volume level of a connected room can be controlled when the room is in Volume Control mode. To switch to
Volume Control mode:
1. Press and hold the button of the room to be controlled for 2 seconds.ROOM
Press j k or to change the volume in 1 dB increments.
Hold j k or for more than 1 second, to ramp the volume up or down in 1 dB/0.1 second
increments.
If the maximum volume or minimum volume is reached, all of the front panel LEDs blink three times.
2. Press the button again to exit ROOM Volume Control mode.
If j k or is not pressed for 10 seconds, the amplifier automatically exits Volume Control mode.
Operation
LAN
COMPUTER
PWR NET HW-R SW-R ACQUIRE AC TIVITY
MC3
123456
ANALOG SOURCES
CAUTION
RISK OF E L ECT R IC S H O CKDO NOT OPEN
AVIS: RISQUE DE CHOC EL E C T R IQUE NE PA S OUV R IR
CAUTIONDISCONNECT AC POWER
BEFORE CONNECTINGSPEAKERS AND PERIPHERALS
SPEAKER OUTP UTS
ELECT RONICS I NC. ROCKL EI GH N.J . 0 78 4 7 US A
LOOP THRU
NET
L R L R L R L R L R L R
IN
OUT
L + - + - R
L + - + - R
L + - + - R L + - + - R
24 Y Z G
24 Y Z G
24 Y Z G 24 Y Z G24 Y Z G 24 Y Z G
POWER 24VDC 5W/PORT CLASS 2
1
23
4
1
2
3
4
8Ω 50W 4Ω 75W CLASS 2 WIRING
G
120V
50Hz400W
Use Crestron Toolbox™ to communicate with the C2N(I)-AMP-4X100. Refer to the
Crestron Toolbox help file for details.
There is a single method of communication: Indirect communication.
NOTE: Required for setting the Net ID and loading firmware.
3
quickstart guide
C2N(I)-AMP-4X100
www.crestron.com
Specifications subject to
change without notice.
C2N(I)-AMP-4X100
For Regulatory Compliance information, refer to the latest version
of Doc. 7289.
QUICKSTART DOC. 7288B (2032394, Sheet 2 of 2) 04.13
4 Room Audio System
6Dimensions
13.64 in
(347 mm)
3.60 in
(92 mm)
16.89 in
(429 mm)
SPECIFICATION DETAILS
Audio
Controls
Volume Gain Range
Mute
Input Compensation
Bass Gain Range
Treble Gain Range
Frequency Response
S/N Ratio
THD + N
Stereo Separation
Power Requirements
Main Power
Available Network Power
Environmental
Temperature
Humidity
Heat Dissipation
Dimensions
Height
Width
Depth
Weight
Volume, Balance, Bass, Treble, Loudness,
Mute, Mono, Input Compensation
-80 dB to +20 dB, 1 dB steps
-100 dB (electronic)
±10 dB
±12 dB @ 100 Hz, 2 dB steps
±12 dB @ 10 kHz, 2 dB steps
20 Hz to 20 kHz ±1.0 dB
103 dB, 20 Hz to 20 kHz, A-weighted
0.8%, 20 Hz to 20 kHz
>70 dB
120 volts ac, 60 Hz (C2N-AMP-4X100)
230 volts ac, 50/60 Hz (C2NI-AMP-4X100)
5 watts per each connection (no NET 1-4
power on “Loop-Thru”); 24 volts dc
41° to 122° F (5° to 50° C)
10% to 90% RH (non-condensing)
174 Btu/h
3.60 in (92 mm)
16.89 in (429 mm)
13.64 in (347 mm)
20.0 lb (9.0 kg)
7Specifications
The specific patents that cover Crestron products are listed at patents.crestron.com.
Crestron, the Crestron logo, Cresnet, and Crestron Toolbox are either trademarks or registered trademarks of
Crestron Electronics, Inc. in the United States and/or other countries. Other trademarks, registered
trademarks and trade names may be used in this document to refer to either the entities claiming the marks
and names or their products.
Crestron disclaims proprietary interest in the marks and names of others.
Crestron is not responsible for errors in typography or photography.
This document was written by the Technical Publications department at Crestron.
©2013 Crestron Electronics, Inc.

Specyfikacje produktu

Marka: Crestron
Kategoria: przełącznik
Model: C2NI-AMP-4X100

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Crestron C2NI-AMP-4X100, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje przełącznik Crestron

Instrukcje przełącznik

Najnowsze instrukcje dla przełącznik