I N S T A L L A T I O N I N S T R U C T I O N S
CMA105
CMA110
CMA115
Ceiling Plates
Spanish Product Description
German Product Description
Portuguese Product Description
Italian Product Description
Dutch Product Description
French Product Description
CMA105-110-115
CMA105-110-115 Installation Instructions
2
DISCLAIMER
Milestone AV Technologies and its affiliated corporations and
subsidiaries (collectively "Milestone"), intend to make this
manual accurate and complete. However, Milestone makes no
claim that the information contained herein covers all details,
conditions or variations, nor does it provide for every possible
contingency in connection with the installation or use of this
product. The information contained in this document is subject
to change without notice or obligation of any kind. Milestone
makes no representation of warranty, expressed or implied,
regarding the information contained herein. Milestone assumes
no responsibility for accuracy, completeness or sufficiency of
the information contained in this document.
Chief® is a registered trademark of Milestone AV Technologies.
All rights reserved.
IMPORTANT SAFETY INSTRUCTIONS!
WARNING: A WARNING alerts you to the possibility of
serious injury or death if you do not follow the instructions.
CAUTION: A CAUTION alerts you to the possibility of
damage or destruction of equipment if you do not follow the
corresponding instructions.
WARNING: Failure to read, thoroughly understand, and
follow all instructions can result in serious personal injury,
damage to equipment, or voiding of factory warranty! It is the
installer’s responsibility to make sure all components are
properly assembled and installed using the instructions
provided.
WARNING: Failure to provide adequate structural strength
for this component can result in serious personal injury or
damage to equipment! It is the installer’s responsibility to
make sure the structure to which this component is attached
can support five times the combined weight of all equipment.
Reinforce the structure as required before installing the
component.
WARNING: Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the
installer’s responsibility to make sure the combined weight of
all components attached to the CMA mount does not exceed
500 lbs (226.8 kg).
NOTE: The weight capacity of the CMA mounts may be
LIMITED to the lowest weight capacity of any other
component located between the ceiling plate and the
projector/display.
WARNING: Use this mounting system only for its intended
use as described in these instructions. Do not use
attachments not recommended by the manufacturer.
WARNING: Never operate this mounting system if it is
damaged. Return the mounting system to a service center for
examination and repair.
WARNING: Do not use this product outdoors.
NOTE: CMA105, CMA110, CMA115 are intended to be used
with a 1-1/2" NPT or NPSM following ANSI/ASME
B1.20.1 (Schedule 40, 0.154" minimum thickness
aluminum - ASTM B221) threaded extension column
(not included).
IMPORTANT ! : These CMA mounts are designed to be:
mounted to a 2" x 6" wood framework ceiling
covered with 5/8" drywall;
mounted to an 8" concrete ceiling using either
1/4" x 2-1/2" lag bolts for Toggler AF8 anchors
(not included), or 5/16" x 2-1/2" lag bolts for
Fischer UX10 concrete anchors (not included);
suspended from four 3/8" diameter (minimum)
Grade 2 or better threaded rods with 16 threads
per inch (not included) which are secured to a
framing channel (spanning a maximum of 5 feet
--not included) by Grade 2 or better 3/8" channel
nuts (not included).
NOTE:
These CMA mounts provide vertical adjustments in 3/4"
increments.
NOTE: CMA105, CMA110 and CMA115 may be used with UL
Listed CMA151 1-1/2" to 1" NPT Adapter Accessory.
WARNING: Do NOT attach to vertical mounting surfaces
such as walls or angled ceilings!
--SAVE THESE INSTRUCTIONS--
Installation Instructions CMA105-110-115
3
DIMENSIONS
.68
17.254
1.50
38.100
3.00
76.200
4.00
101.600
4.00
101.600
1.35
34.163
2.690
68.326
4X .44 X .75 SLOT
[11.2 X 19.0]
1 1/2 NPT
DIMENSIONS: INCHES
[MILLIMETERS]
CMA105
.68
17.254
3.25
82.550
6.50
165.100
8.00
203.200
8.00
203.200
.75
19.050
3.09
78.457
6.19
157.226
.91
22.987
4X .44 X .75 SLOT
[11.2 X 19.0]
1 1/2 NPT
DIMENSIONS: INCHES
[MILLIMETERS]
CMA110


Specyfikacje produktu

Marka: Chief
Kategoria: Wsparcie dla płaskich paneli
Model: CMA110

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Chief CMA110, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Wsparcie dla płaskich paneli Chief

Chief

Chief TS218SU Instrukcja

9 Grudnia 2024
Chief

Chief PFQUB Instrukcja

6 Października 2024
Chief

Chief MFQUB Instrukcja

5 Października 2024
Chief

Chief PFMUB Instrukcja

5 Października 2024
Chief

Chief K4G210B Instrukcja

23 Września 2024
Chief

Chief MF26000B Instrukcja

23 Września 2024
Chief

Chief FSB018BLK Instrukcja

23 Września 2024
Chief

Chief TPK1 Instrukcja

22 Września 2024
Chief

Chief PDR2612B Instrukcja

22 Września 2024
Chief

Chief CMA395 Instrukcja

22 Września 2024

Instrukcje Wsparcie dla płaskich paneli

Najnowsze instrukcje dla Wsparcie dla płaskich paneli