Instrukcja obsługi Auray CFP-ET


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Auray CFP-ET (2 stron) w kategorii Niesklasyfikowane. Ta instrukcja była pomocna dla 6 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/2
CFP-ET Series
Carbon Fiber
Extension Tubes
for CFP-Series Boom Poles
Owners Manual
Extension tube
accessory for use
with Auray CFP-
series boom poles.
Manufactured with
sturdy, lightweight
carbon ber for
portability and
reliability.
Integrated cable
with high-quality
TA3 (mini XLR)
connectors
manufactured by
Rean® (a registered
trademark of
Neutrik®).
www.AurayAudio.com
Adding an Extension Boom Pole with
Side-Exit XLR
1. Unscrew the side exit housing, 1 and
move the plastic strain relief cap so that
the TA3 connector inside the housing is
exposed.
2. Disconnect the TA3 connector by pressing
on the locking tab and gently removing the
connector from the mount. 2
Note: The TA3 connector should easily
disconnect. Do not force or pull on the
cable to disconnect it. Doing so could
damage the housing or the connector.
3. Use a small slotted screwdriver to reach
inside the strain relief and depress the
locking tab of the TA3 connector. With the
locking tab depressed, you can slide the
strain relief over the TA3 connector and o
of the cable. 3 Set the strain relief piece
aside.
4. Connect the male TA3 connector of the
included cable to the female TA3 connector
of the coiled cable of the boom pole.
5. Snake the included cable through the
extension tube.
6. Screw the extension tube onto the end of
the boom pole.
7. Fit the narrow side of the strain relief over
the TA3 connector, and push it past the
TA3 connector’s locking tab. 4
8. Plug the TA3 connector into the bottom
housing by inserting it into the TA3 mount
and pushing in until it clicks.
Note: When properly aligned, the TA3
connector will easily slide into place.
Do not try to force the connector into
the mount. Doing so could damage the
connector or the mount.
9. Push the strain relief all the way into the
side exit housing so it sits over the TA3
connector. 5
10. Screw the side exit housing onto the end of
the boom pole.
5
4
1
2
3
Auray is a registered trademark of the
Gradus Group. © 2016 Gradus Group LLC.
All Rights Reserved. GG2
Please read and follow
these instructions, and
keep this manual in a safe
place.
Handle the product with
care.
Use only parts provided by
the manufacturer.
Make sure the item is
intact and that there are no
missing parts.
All photos are for
illustrative purposes.
Adding an Extension Boom Pole with
Bottom-Exit XLR
1. Unscrew the bottom housing from the base
of the boom pole. 1
2. Unscrew the plastic TA3 strain relief. 2
3. Disconnect the TA3 connector by pressing
on the locking tab and gently removing the
connector from the mount.
Note: The TA3 connector should easily
disconnect. Do not force or pull on the cable
to disconnect it. Doing so could damage the
housing or the connector.
4. Use a small slotted screwdriver to reach
inside the strain relief and depress the
locking tab of the TA3 connector. 3 With
the locking tab depressed, you can slide the
strain relief over the TA3 connector and oof
the cable. Set the strain relief piece aside.
5. Connect the male TA3 connector of the
included cable to the female TA3 connector
of the coiled cable of the boom pole.
6. Snake the included cable through the
extension tube.
7. Screw the extension tube onto the end of the
boom pole.
8. Fit the narrow side of the strain relief over
the TA3 connector, and push it past the TA3
connector’s locking tab. 4
9. Plug the TA3 connector into the bottom
housing by inserting it into the TA3 mount
and pushing in until it clicks.
Note: When properly aligned, the TA3
connector will easily slide into place. Do not
try to force the connector into the mount.
Doing so could damage the connector or the
mount.
10. Screw the threaded end of the strain relief
onto the threaded fitting on the bottom
housing. 5
11. Screw the bottom exit housing onto the end
of the boom pole.
Instructions
XLR cable with
Rean® TA3
connectors
The TA3 (mini XLR)
connectors manufactured
by Rean® (a registered
trademark of Neutrik)
provide a secure locking
connection and maximum
signal transfer.
Sturdy lightweight
carbon ber
The CFP series features
matrix reinforced carbon
ber composite tubes
that oer exceptional
strength-to-weight ratio.
The lightweight design
reduces handling fatigue
during lengthy sessions.
They are designed to
withstand the rigors of eld
use, and are comfortable
to handle even in extreme
temperatures.
Tube Diameter:
1.25 (31.3 mm)
Tube Length:
CFP-ET2: 2 (0.6 m)
CFP-ET3: 3 (0.9 m)
CFP-ET4: 4 (1.2 m)
CFP-ET5: 5 (1.5 m)
CFP-ET6: 6 (1.8 m)
Cable Connectors:
TA3 Male to TA3 Female
Specications
Precautions
2
3
Introduction
Thank you for choosing Auray.
The Auray CFP-ET-series
extension tubes are extensions for
Aurays CFP-series boom poles.
Made of the same lightweight and
durable carbon ber construction
as the CFP boom poles, these
extensions will add length to the
boom pole without sacricing
strength. The TA3 (mini XLR)
cable is engineered to be
compatible and work flawlessly
with every component of the CFP
boompole series.
4
5
1


Specyfikacje produktu

Marka: Auray
Kategoria: Niesklasyfikowane
Model: CFP-ET

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Auray CFP-ET, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Auray

Auray

Auray RF-PBO Instrukcja

27 Września 2024
Auray

Auray CFC-610 Instrukcja

27 Września 2024
Auray

Auray COHH-FD1 Instrukcja

27 Września 2024
Auray

Auray RFDT-128 Instrukcja

27 Września 2024
Auray

Auray CFP-ET6 Instrukcja

27 Września 2024
Auray

Auray BP-59A Instrukcja

27 Września 2024
Auray

Auray RF-5P-B Instrukcja

27 Września 2024
Auray

Auray PBS-AH Instrukcja

27 Września 2024
Auray

Auray BP-36A Instrukcja

27 Września 2024
Auray

Auray LTS-ST Instrukcja

27 Września 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024