Instrukcja obsługi APC GVSMODBC6


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla APC GVSMODBC6 (44 stron) w kategorii Niesklasyfikowane. Ta instrukcja była pomocna dla 7 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/44
Galaxy VS
Modular Battery Cabinet
Installation
Up to 6 Battery Strings
GVSMODBC6
6/2019
www.schneider-electric.com
Legal Information
The Schneider Electric brand and any trademarks of Schneider Electric SE and its
subsidiaries referred to in this guide are the property of Schneider Electric SE or its
subsidiaries. All other brands may be trademarks of their respective owners.
This guide and its content are protected under applicable copyright laws and
furnished for informational use only. No part of this guide may be reproduced or
transmitted in any form or by any means (electronic, mechanical, photocopying,
recording, or otherwise), for any purpose, without the prior written permission of
Schneider Electric.
Schneider Electric does not grant any right or license for commercial use of the guide
or its content, except for a non-exclusive and personal license to consult it on an "as
is" basis. Schneider Electric products and equipment should be installed, operated,
serviced, and maintained only by qualified personnel.
As standards, specifications, and designs change from time to time, information
contained in this guide may be subject to change without notice.
To the extent permitted by applicable law, no responsibility or liability is assumed by
Schneider Electric and its subsidiaries for any errors or omissions in the informational
content of this material or consequences arising out of or resulting from the use of the
information contained herein.
Go to
IEC: https://www.productinfo.schneider-electric.com/portals/ui/galaxyvs_iec/ or
UL: https://www.productinfo.schneider-electric.com/portals/ui/galaxyvs_ul/
or scan the QR code above for digital experience and translated manuals.
Modular Battery Cabinet
Table of Contents
Important Safety Instructions SAVE THESE
INSTRUCTIONS .........................................................................................5
FCC Statement ..........................................................................................6
Electromagnetic Compatibility .....................................................................6
Safety Precautions .....................................................................................6
Additional Safety Precautions After Installation........................................8
Electrical Safety .........................................................................................8
Battery Safety ............................................................................................9
Modular Battery Cabinet Specifications ................................................ 10
Torque Specifications................................................................................12
Modular Battery Cabinet Weights and Dimensions ...................................... 12
Clearance ................................................................................................12
Environment.............................................................................................13
Overview of Installation Kits ....................................................................14
Installation Procedure .............................................................................. 17
Prepare for Installation .............................................................................19
Install the Conduit Box on the Modular Battery Cabinet ..................... 20
Prepare Modular Battery Cabinet 1 for Signal Cables ........................21
Install the Seismic Anchoring (Option) .................................................. 22
Interconnect Modular Battery Cabinet 1 and the Adjacent UPS
with Internal Batteries...............................................................................23
Interconnect Modular Battery Cabinet 1 and the Adjacent UPS
for External Batteries................................................................................24
Interconnect the Modular Battery Cabinets .......................................... 27
Connect the Power Cables for a UPS Rated for Maximum 50
kW ............................................................................................................... 28
Connect the Power Cables for a UPS Rated over 50 kW...................31
Connect the Signal Cables ...................................................................... 34
Add Translated Safety Labels to Your Product.....................................38
Final Installation ........................................................................................ 39
990-91263-001 3


Specyfikacje produktu

Marka: APC
Kategoria: Niesklasyfikowane
Model: GVSMODBC6

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z APC GVSMODBC6, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane APC

APC

APC FS-AC-8002-U Instrukcja

15 Października 2024
APC

APC EVP1000 Instrukcja

14 Października 2024
APC

APC Switched Rack PDU Instrukcja

9 Października 2024
APC

APC C2C Instrukcja

9 Października 2024
APC

APC AP7868 Instrukcja

9 Października 2024
APC

APC P8VNTG Instrukcja

9 Października 2024
APC

APC P62 Instrukcja

9 Października 2024
APC

APC AP7898 Instrukcja

9 Października 2024
APC

APC SBP6KRMI2U Instrukcja

7 Października 2024
APC

APC W0M-7054 Instrukcja

7 Października 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024