Instrukcja obsługi APC BN450MNW
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla APC BN450MNW (15 stron) w kategorii UPS. Ta instrukcja była pomocna dla 2 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/15
User Manual Back-UPS BN450MNW
Safety and General Information
Inspect the package contents upon receipt. Notify the carrier and dealer if there is
any damage.
SAVE THESE INSTRUCTIONS - This section contains important instructions that
should be followed during installation and maintenance of the UPS and batteries.
CAUTION: A battery can present a risk of electric shock and burns by high short-circuit
current.
CAUTION: Failed batteries can reach temperatures that exceed the burn thresholds for
touchable surfaces.
Inventory
DANGER
RISK OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
• This UPS is intended for indoor use only.
• Do not operate this UPS in direct sunlight, in contact with fluids, or where
there is excessive dust or humidity.
• Connect the UPS power cable directly to a wall outlet.
• Be sure the air vents on the UPS are not blocked. Allow adequate space for
proper ventilation.
Failure to follow these instructions will result in death or serious injury.
bu462a
Back-UPS BN450MNW2
Connect the Battery
The Back-UPS is shipped with one battery cable disconnected.
Specifications
Remove the “Stop! Connect the Battery”
label that covers the outlets. The battery connector is located on the
underside of the unit.
Slide the battery connector handle away
from its disconnected position.
Turn the battery connector to a 90-degree
upright position and push it into the unit.
Model BN450MNW
Input Voltage 120 Vac Nominal
Frequency 50/60 Hz + 1 Hz auto-sensing
Brownout Transfers 92 Vac Typical
Over-voltage Transfer 139 Vac Typical
Output UPS Capacity 450 VA, 255 W
No. of Outlets 6
Battery Backup / Surge Outlets 4 / 2
Total output current 6 A
Voltage - On Battery 115 Vac ± 8%
Frequency - On Battery 50/60 Hz + 1 Hz
Transfer Time 4 ms Typical
Protection
and
Filtering
EMI/RFI Filter Full time
AC Input Resettable circuit breaker
Battery Type Sealed, maintenance-free, lead acid, 12 V
Average Life 3 - 5 years, the number of discharge cycles,
poor quality AC power, environmental
temperature and humidity may shorten the
battery lifetime
Charging Time 8 hours
bu
462a
bu463a
bu464a
bu465a
Back-UPS BN450MNW 3
Connect Equipment
.
Turn On the Back-UPS
Press the POWER button. It will illuminate green and a single short beep indicates that the
Back-UPS is on and helping to provide protection for connected equipment.
The Back-UPS battery will charge regardless of whether the Back-UPS is switched on or
off as long as it is connected to AC power. The UPS will have full runtime capability after
the initial 24-hour charging period, connected to AC power.
If the Building Wiring Fault indicator (located on the end near the power cord) is
illuminated red, your building wiring may present a shock hazard that should be corrected
by a qualified electrician.
Turn Off the Back-UPS
Press the POWER button for at least 2 seconds. At the first beep, release the button and the
UPS will turn off. A 2 second delay has been added to mitigate unintentional contact with
the POWER button.
Physical Net Weight 5.7 lb (2.6 kg)
Dimensions
LxWxH
9.98 in x 4.13 in x 5.51 in
25.35 cm x 10.5 cm x 14.02 cm
Operating Temperature 32 ºF to 104 ºF (0 ºC to 40 ºC)
Storage Temperature -4 ºF to 122 ºF (–20 ºC to 50 ºC)
Operating Relative Humidity 0 to 95% non-condensing humidity
Operating Elevation 0 to 10,000 ft (0 to 3000 m)
International Protection Code IP20
Feature Function Suggested Use
Battery Backup +
Surge Protection
Outlets
Receive power from the battery for a
limited period of time when a power
outage, or brownout condition occurs.
Help to provide protection from
power surges or spikes.
Connect a computer, monitor
and other essential peripheral
devices that need to remain on
during power outages or AC
problems.
Surge Protection
Outlets
Help to provide protection from
power surges or spikes.
Connect non-essential
peripheral devices (such as
printer, scanner, etc.) that do
not need to remain on during
power outages or AC
problems.
Model BN450MNW
Battery Backup + Surge
Protection Outlets
Surge Protection
Outlets
bu461a
POWER
Button
Back- UPS 450
Surge
bu460a
Building
Wiring
Faul t
AC Power
Inlet
Circuit
Brea ker
Specyfikacje produktu
Marka: | APC |
Kategoria: | UPS |
Model: | BN450MNW |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z APC BN450MNW, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje UPS APC
12 Października 2024
12 Października 2024
12 Października 2024
12 Października 2024
12 Października 2024
12 Października 2024
12 Października 2024
12 Października 2024
9 Października 2024
9 Października 2024
Instrukcje UPS
- UPS Ikea
- UPS AEG
- UPS Voltcraft
- UPS LC-Power
- UPS Tripp Lite
- UPS Block
- UPS V7
- UPS Digitus
- UPS FSP
- UPS Online USV
- UPS Equip
- UPS Emerson
- UPS CyberPower
- UPS JUNG
- UPS Eaton
- UPS Adj
- UPS PowerWalker
- UPS Salicru
- UPS Energenie
- UPS Steren
- UPS East
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Furman
- UPS Minuteman
- UPS Riello
- UPS Maruson
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Approx
- UPS Altronix
- UPS Bxterra
- UPS Middle Atlantic
- UPS Atlantis Land
- UPS FSP/Fortron
Najnowsze instrukcje dla UPS
11 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024