Temperature and Humidity Sensor
Installation Sheet
Inventory
Install the sensor
1. Find a suitable location to mount the sensor, such as an area that contains mixed, moving air.
Note: Avoid installing the sensor near an area that could cause an inaccurate
reading, such as near air ducts, windows, exterior walls, or room entrances.
2. Mount the sensor using screws or hook-and-loop
fasteners:
Using screws:
Mark and drill two holes, 3/32 in (2.38 mm) in
diameter and 1.53 in (38.8 mm) apart.
Temperature and Humidity
Sensor with Display or
Temperature Sensor with Display
(1)
#6 × 3/4-in Phillips
self-tapping screws
(4)
Hook-and-loop
fasteners
(2)
Terminator
(1)
Warning: Before drilling, check
for unexposed wiring behind
the drilling surface.
Temperature and Humidity Sensor Installation2
Using hook-and-loop fasteners:
Clean the mounting surface so that it is free of
dust, oils, and moisture. Install the sensor using
both hoop-and-loop fasteners. Hold them in place
for five seconds to ensure a firm adhesion.
3. Route a cable from the sensor to the
device that will monitor the sensor.
When using more than one sensor:
Route a cable from one sensor to
the next. Each connection on the
sensor should have either a CAT 5
cable or a terminator (0W04161)
(provided).
Set the A-Link address
Set the DIP switches on each sensor to a unique A-Link address.
See the documentation provided with the monitoring device for A-Link addresses. Each
sensor must be set with a unique A-Link address. Some addresses are reserved for use by the
monitoring device. The addresses for sensors will vary depending on the monitoring device to
which they are connected.
Screen menus
At three-second intervals, the display scrolls through two screens (for AP9520T) or three screens (for
AP9520TH).
1 2 3 4
1=
2=
1 2 3 4
1 2 3 4
3=
1 2 3 4
1 2 3 4
4=
1 2 3 4
5=
1 2 3 4
1 2 3 4
1 2 3 4
6=
7=
8=
Temperature and Humidity Sensor Installation 3
Specifications
* In airflow of >100 ft/min.
Electrical
Operating Voltage 24 VDC nominal
Operating Current 10 mA (max)
Temperature Accuracy* ± 1.8° F (1.0°C)
Temperature Drift* ± 0.36°F (0.2° C)/over life of unit
Humidity Accuracy (AP9520TH) * ± 3.0% RH @ 25°C
Humidity Drift (AP9520TH) * ± 1.0% RH/5 years
Physical
Size (H × W × D) 3.9 × 1.7 × 1.1 in
10.0 × 4.35 × 2.75 cm
Weight 2.7 oz (76 g)
Environmental
Elevation
Operating 0 to 10,000 ft (0 to 3000 m)
Storage 0 to 50,000 ft (0 to 15 000 m)
Temperature
Operating 4 to 140°F (–20 to 60°C)
Storage 40 to 176°F (–40 to 80°C)
Approvals
EMC Verification AS/NZS CISPR 22 (C-Tick) Class A,
CE, EN 55022 Class A, EN 55024,
FCC Part 15 Class A, ICES-003,
VCCI


Specyfikacje produktu

Marka: APC
Kategoria: Niesklasyfikowane
Model: AP9520TH

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z APC AP9520TH, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane APC

APC

APC FS-AC-8002-U Instrukcja

15 Października 2024
APC

APC EVP1000 Instrukcja

14 Października 2024
APC

APC Switched Rack PDU Instrukcja

9 Października 2024
APC

APC C2C Instrukcja

9 Października 2024
APC

APC AP7868 Instrukcja

9 Października 2024
APC

APC P8VNTG Instrukcja

9 Października 2024
APC

APC P62 Instrukcja

9 Października 2024
APC

APC AP7898 Instrukcja

9 Października 2024
APC

APC SBP6KRMI2U Instrukcja

7 Października 2024
APC

APC W0M-7054 Instrukcja

7 Października 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024