Instrukcja obsługi AMX NetLinx NX-4200

AMX nieskategoryzowany NetLinx NX-4200

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla AMX NetLinx NX-4200 (2 stron) w kategorii nieskategoryzowany. Ta instrukcja była pomocna dla 13 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/2
QUICK START GUIDE
NX-4200 NetLinx NX Integrated Controller
Overview
This guide pertains to the NX-4200 NetLinx NX Integrated Controller (FG2106-04). The
purpose of this document is to illustrate how to set up the device in its simplest
configuration. Additional Documentation for this device is available at www.amx.com:
Refer to the NX-x200 Series Hardware Reference Manual for additional details on
installing, upgrading, and wiring the NX-4200.
Refer to the NX Series NetLinx Integrated Controllers WebConsole & Programming
Guide for detailed configuration instructions.
You can access this Quick Start Guide online by using your mobile device to scan
the QR code located on the bottom of the NX-4200.
What’s in the Box?
The following items are included with the NX-4200:
1 2-pin 3.5 mm mini-Phoenix (female) PWR connector
2 4-pin 3.5 mm mini-Phoenix (female) AxLink connector
2 6-pin 3.5 mm mini-Phoenix female I/O connectors
2 8-pin 3.5 mm mini-Phoenix female Relay connectors
2 10-pin 3.5mm mini-Phoenix female RS232/422/485 connectors
6 5-pin 3.5mm mini-Phoenix female RS232 connectors
2 CC-NIRC, IR Emitters (FG10-000-11)
2 removable rack ears
Environmental Requirements
The environmental requirements for the NX-4200 are as follows:
Operating Temperature: 32° F (0° C) to 122° F (50° C)
Storage Temperature: 14° F (-10° C) to 140° F (60° C)
Operating Humidity: 5% to 85% RH
Modes and Front Panel LED Blink Patterns
The following table lists the modes and blink patterns for the front panel LEDs
associated with each mode. These patterns are not evident until after the unit is
powered.
Connecting to Your Controller
NOTE: Ensure the PC you are using to connect to the controller has the latest version of
NetLinx Studio 4.0 installed on it.
Once the controller is powered on, you can connect to it through its IP address.
NOTE: NX-Series controllers fully support IPv6 network addressing. If the LAN port is
connected to an IPv6 capable network it will self select an appropriate IPv6 address
based on the discovered address parameters of the network to which it’s attached.
Connecting to the NX-4200 over Ethernet
The NX-4200 is configured for DHCP addressing by default. The controller uses link
local addressing as a backup in case the DHCP server is inaccessible. See the Changing
the IP Address section for information on setting a static IP address. Verify there is an
active LAN connection on the controllers LAN port before beginning this procedure.
1. Using category cable, connect the LAN port on the rear panel of the controller to
your external network.
FIG. 1 displays the location of the LAN port on the rear panel.
FIG. 1 NX-4200 REAR PANEL
2. In NetLinx Studio, select Settings > Workspace Communications Settings to
open the Workspace Communication Settings dialog.
3. Click System Settings to open the Communication Settings dialog, and select the
Network tab.
4. Click Listen for Masters to open the Listen For Masters dialog, and click Start
Listening to begin listening for “blink” (UDP) messages from NetLinx Masters on
the same subnet. As Masters are discovered, they are added to the List of Active
NetLinx Master Controllers.
5. When you see the IP Address for the target Master in the List of Active NetLinx
Master Controllers, click Stop Listening.
6. Select the IP Address of the target Master and click Select to Add. The New TCP/
IP Setting dialog appears, indicating the selected IP address. Fill in the available
fields as necessary. Click OK to save changes and return to the Communication
Settings dialog. The new Masters IP address now appears in the List of
Addresses.
7. With the newly added Master selected, click Select. The window updates to
indicate that the newly added and selected Master is now the current
communication configuration.
8. Click OK on each open dialog to exit and return to the workspace.
9. Refresh the Online Tree (select Refresh System Online Tree from the Online Tree
context menu) to connect to the Master.
Connecting to the NX-4200 via USB
If you do not have a DHCP server or if the controller has an unknown static IP address,
you obtain the IP address of the controller via USB.
1. Using a standard Type-B to Type-A USB cable, connect the Program Port on the
front panel of the controller to your PC.
FIG. 2 displays the location of the Program Port.
FIG. 2 NX-4200 FRONT PANEL
2. Select Settings > Workspace Communications Settings to open the Workspace
Communication Settings dialog.
3. Click System Settings to open the Communication Settings dialog.
4. Select the USB tab. The USB tab features a list of Masters connected to your PC
via USB. The IP address of the Master appears in the IPv4 Address column.
5. Highlight your Master and click Select to connect to it.
Retrieving the IP Address of the NX-4200
The NX-4200 is configured for DHCP addressing by default. The controller uses link
local addressing as a backup in case the DHCP server is inaccessible. The IP address of
the NX-4200 is accessible from the front panel LCD display on the unit.
1. Press the Display Control button on the front panel. The LCD display beside the
button activates.
2. Press downward on the Display Control button to navigate through the status
parameters until you reach LAN IPv4 Address. This is your controller’s IP address
which you can use to access the WebConsole.
FIG. 3 DISPLAY CONTROL BUTTON
Switching the IP Address from a Dynamic to Static
To toggle between static and dynamic IP addresses, hold the ID pushbutton on the front
panel of the NX-4200 for 10 seconds. When complete, the controller automatically
reboots itself. After the controller is fully booted, use the Workspace Communications
Settings dialog in NetLinx Studio to create a new connection to the controller. See the
Default IP Addresses section for the list of default IP addresses.
NOTE: Ensure the controller is fully booted when you press and hold the ID pushbutton.
Pressing and holding the ID pushbutton while the controller is booting resets the unit to
its factory defaults.
MODES AND LED BLINK PATTERNS
LEDs and Blink Patterns
Mode
STATUS
(green)
OUTPUT
(red)
INPUT
(yellow)
Boot ON OFF ON
Contacting DHCP
server
ON OFF Fast Blink
Using link-local
address
Slow Blink OFF OFF
Program running Slow Blink ON when
transmitting data
ON when receiving
data
No program running ON ON when
transmitting data
ON when receiving
data
Connect category cable
to the LAN port
Connect Type-B USB cable
to the Program Port
Display Control button
© 2015 Harman. All rights reserved. NetLinx, WebControl, AMX, AV FOR AN IT WORLD, and HARMAN, and their respective logos are registered
trademarks of HARMAN. Oracle, Java and any other company or brand name referenced may be trademarks/registered trademarks of their
respective companies.
AMX does not assume responsibility for errors or omissions. AMX also reserves the right to alter specifications without prior notice at any time.
The AMX Warranty and Return Policy and related documents can be viewed/downloaded at www.amx.com.
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 AMX.com | 800.222.0193 | 469.624.8000 | +1.469.624.7400 | fax 469.624.7153
AMX (UK) LTD, AMX by HARMAN - Unit C, Auster Road, Clifton Moor, York, YO30 4GD United Kingdom • +44 1904-343-100 • www.amx.com/eu/
93-2106-04 REV: G
Last Revised: 12/28/2015
Changing the IP Address Once You Are Connected
Perform these steps to change the IP address once you are connected to the controller:
1. Set the IP address on your PC to the same network the controller is currently on.
2. In NetLinx Studio, select Diagnostics > Network Addresses from the menu bar to
open the Network Addresses dialog.
3. Click Get IP Information to enable the fields for editing.
4. Enter the System, Device (0 for NetLinx Masters), and Host Name information.
5. To specify a network IP address, select Specify IP Address.
6. Enter the IP parameters into the available fields.
7. Click Set IP Information to retain the pre-reserved IP Address to the Master.
8. Click Reboot Device to finish assigning the IP address to the Master, and click OK
to close the dialog.
Accessing the WebConsole
NetLinx controllers have a built-in WebConsole that allows you to make various
configuration settings via a web browser on any PC with access to the controller.
The WebConsole consists of a series of web pages that are collectively called the
“Master Configuration Manager”. Refer to the NX Series NetLinx Integrated Controllers
WebConsole & Programming Guide for details on the WebConsole.
From any PC with access to the LAN that the target controller resides on:
1. Open a web browser and type the IP Address of the controller in the Address Bar.
2. Press Enter to access WebConsole for the controller. The initial view is the
WebConsole page.
FIG. 4 WEBCONSOLE (MAIN PAGE)
Default Settings
The following sections list the default settings for the controller.
Default User Names and Passwords
The following table lists the default user names and passwords for accessing the
NX-4200 through NetLinx Studio or the WebConsole.
Default IP Addresses
The following table lists the default IP addresses for the NX-4200.
Conf iguration
All items in this section require accessing the WebConsole.
Enabling Security
To enable security:
1. Select the Security tab on the WebConsole. The System Security Details appear.
2. Click the Enabled check box to enable security and activate the Access options.
3. Select the Access options which you want to require a login and password.
4. Configure users and groups as necessary.
Wired 802.1x Security
The X-Series controllers support wired 802.1x, an IEEE Standard for Port-based
Network Access Control. To enable wired 802.1x, you must load an 802.1x certif icate
file to your controller using NetLinx Studio. Once you add the certificate file to your
workspace, NetLinx Studio transfers the file to the appropriate directory on the
controller.
1. Click to select (highlight) a System (in the Workspace tab of the Workspace Bar).
2. Right-click on the Other folder to access the Other File Folder context menu, and
select Add Existing Other File.
3. In the Add Existing Other File dialog, locate and select the certificate file (.crt) that
you want to add to the selected System. Change the Files of Type option to All
Files (*.*) to look for other file types, if necessary.
4. Click Open to access the File Properties dialog, where you can view/edit general
file information for the selected file.
5. Click OK to add the file to the selected System. The file should now appear in the
Other folder under the selected System.
Setting the Clock Manager Mode
To set the clock manager mode:
1. On the Manage System tab, select a Time Sync option.
Network Time: When this option is selected, the controller will connect to the
default NIST Server to get date and time information. You can select a different
NIST Server (or specify the IP Address of a known NIST Server) on the NIST
Servers tab.
Stand Alone: This option lets the controller use its own internal clock. When this
option is selected, the Date and Time fields are available on this tab.
2. Click Accept to save these settings to the controller.
Hardware Information
This section lists important hardware information for the NX-4200.
Port Numbers
Mounting the NX-4200
The NX-4200 ships with removable rack ears for installation into an equipment rack.
Use the supplied #8-32 screws to secure the rack ears to the sides of the controller. You
can attach the rack ears toward the front or rear panel for either a front-facing or
rear-facing installation.
Use the four #10-32 screws supplied in the mounting kit to secure the controller to the
rack.
DEFAULT USER NAMES AND PASSWORDS
User Name Password
NetLinx Studio netlinx password
WebConsole administrator password
DEFAULT IP ADDRESSES
IP Address Subnet
Static IP 192.168.1.3 255.255.255.0
ICSLAN 198.18.0.1 255.255.0.0
Link-local 169.254.x.y, where x and y are the least significant two octets of the
MAC address.
NX-4200 PORT NUMBERS
RS-232 RS-422/485 IR/Serial I/O Relay
2-4, 6-8 1, 5 11-18 22 21


Specyfikacje produktu

Marka: AMX
Kategoria: nieskategoryzowany
Model: NetLinx NX-4200

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z AMX NetLinx NX-4200, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje nieskategoryzowany AMX

AMX

AMX TPC-BYOD Instrukcja

10 Lipca 2024
AMX

AMX MXR-1001 Instrukcja

21 Czerwca 2024
AMX

AMX DX-RX-4K60 Instrukcja

21 Czerwca 2024
AMX

AMX PR-WP-412 Instrukcja

21 Czerwca 2024
AMX

AMX PSR5.4 Instrukcja

21 Czerwca 2024
AMX

AMX MSA-MMK2-07 Instrukcja

21 Czerwca 2024
AMX

AMX CB-MSA-10 Instrukcja

21 Czerwca 2024
AMX

AMX MXT-700-NC Instrukcja

21 Czerwca 2024
AMX

AMX CB-MXP10-F Instrukcja

21 Czerwca 2024
AMX

AMX VARIA-100 Instrukcja

21 Czerwca 2024

Instrukcje nieskategoryzowany

Najnowsze instrukcje dla nieskategoryzowany

Meec Tools

Meec Tools 010-084 Instrukcja

6 Października 2024
Outwell

Outwell Scenic Road 250 Instrukcja

5 Października 2024
Impact

Impact QuikBalance Instrukcja

4 Października 2024
Impact

Impact CA-112 Instrukcja

4 Października 2024
Impact

Impact LS-BHA Instrukcja

4 Października 2024
Impact

Impact LKB-5C Instrukcja

4 Października 2024
Impact

Impact RST-001 Instrukcja

4 Października 2024