VOLTAGE AND CONTINUITY TESTER
MODEL VPC-10N
Instruction Manual
Safety Information
l Never use the tester if it or its test leads appear damaged.
l Never apply more than 600V DC or 600V AC rms. between
any terminal and earth ground.
l If the LED turns on it indicates the presence of voltage at the
probe tips.
l When using the probes, do not touch the metal probe tips.
l Disconnect the live test lead before disconnecting the common
test lead.
l Before each use, verify the tester’s operation by measuring a
known voltage.
Automatic Operation
The tester automatically turns on when you place the probes
across a complete circuit. The tester selects continuity or DC or AC
voltage mode based on the resistance or voltage between the
probes. The tester automatically turns off when you remove the
probes from the complete circuit.
Measuring Voltage
Connect test leads across the source or load under measurement,
the LED turns on at between 70% and 100% of their rated
voltages.
DC Voltage AC voltage
600V DC maximum 600V RMS
Maximum 45 Hz to 66 Hz
Testing for Continuity
Turn off circuit power before testing. Beeper indicates shorts lasting
1ms or longer
OPEN short or 0-85KW
Non-contact AC Voltage (NCV) detection operating
instructions
WARNING: Risk of Electrocution. High-voltage circuit, both AC and
DC, are very dangerous and should be measured with great care.
WARNING: Risk of Electrocution. Before using to check for voltage
in an outlet, always test the Voltage Tester on a known live circuit to
verify that the Voltage Tester is working properly.
WARNING: Risk of Electrocution. Keep hands and fingers on the
body of the probe and away from the probe tip. Dont touch
conductor.
1. T o check for AC voltage, assure the bottle shaped protrusion of
the fixed probe, see figure below, is in close proximity to the hot
conductor. The LED in the fixed probe will illuminate.
2. To check for the presence of AC voltage at an outlet, using the
NCV LED, insert either probe tip into the outlet’s hot side. If the
black probe is used only the NCV LED will illuminate. If the
fixed probe is inserted not only will the NCV LED illuminate but
some of the LEDs on the front of the instrument will illuminate
also. In this application these LEDs wont indicate the correct
voltage and should be ignored.
SPECIFICATIONS
Function: Range: Accuracy:
AC voltage (V) 24,120,208,240,277,480,600 -30% to 0% of reading
DC voltage (V) 6,12,24,36,48,110,220 -30% to 0% of reading
Continuity Test: Audible threshold 0-85kW, Continuity beeper
2KHz
Maximum Voltage Between any Terminal and Earth Ground:
600V DC; 600V AC RMS, Overvoltage Category III
Input Impedance: 1MW
Non-contact AC Voltage Sensitivity: 100 to 600V (50/60 Hz)
Non-contact AC Voltage detection distance: <0.5 of NCV
sensor
Temperature: Operating: 5°C (41°F) to 40°C (104°F)
Storage : -30˚C to +60˚C_ _
Altitude: Operating: 2000m; Storage: 10,000m
Relative Humidity: 80 for temperature up to 31˚C decreasing
linearly to 50% RH at 40˚C
Battery Type and Life: AA (2); 350 hours with NEDA 15F or IEC
R6
Safety: UL Listed; 61010B-1: For use in Over-Voltage CAT III,
600V environments
EMC Regulations: EN50081-1, EN50082-1
Polution Degree: 2
For indoor use only.
Battery Test and Replacement
Replace the batteries when touching the leads together no longer
turns on the continuity LED.
2xAA
Disconnect probes Do not
from Voltage over-tighten screws
WARRANTY
Congratulations! Your new has instrument been quality crafted according to
quality quality standards and contains components and workmanship. It has
been inspected operation functions for proper of all of its and tested by
qualified according standards factory technicians to the long-established of
our company.
Your instrument against has a limited warranty defective materials and/or
workmanship for one-year from date the of in purchase provided that, the
opinion of the factory, the instrument has not been with tampered or taken
apart.
Should your instrument materials, fail due to defective and/or
workmanship during this one-year period, a no charge repair or
replacement will made be to the original purchaser. Please have your
dated bill sale, which model of must identify the instrument number and
serial number and call the number listed below:
Repair Department /ATP – Amprobe, TIF, Promax
Miramar, FL 33025
Phone: 954-499-5400
Toll Free: 800-327-5060
Fax: 954-499-5418
Website: www.Amprobe.com
Please obtain an RMA number before returning product for repair.
Outside the the U.S.A. local Above representative will you. assist limited
warranty covers repair and and replacement of instrument only no other
obligation is stated or implied.
Miramar, FL
Tel: 954-499-5400 • Fax: 954-499-5418
www.Amprobe.com
P/N: ATP 0403C printed in
China


Specyfikacje produktu

Marka: Amprobe
Kategoria: Niesklasyfikowane
Model: VPC-10N

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Amprobe VPC-10N, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Amprobe

Amprobe

Amprobe AC40C Instrukcja

3 Października 2024
Amprobe

Amprobe DM-CT-100 Instrukcja

30 Września 2024
Amprobe

Amprobe AD40B Instrukcja

29 Września 2024
Amprobe

Amprobe WT-10 Instrukcja

27 Września 2024
Amprobe

Amprobe TMD-51 Instrukcja

23 Września 2024
Amprobe

Amprobe THWD-10W Instrukcja

16 Września 2024
Amprobe

Amprobe NCV-1020 Instrukcja

15 Września 2024
Amprobe

Amprobe WT-60 Instrukcja

15 Września 2024
Amprobe

Amprobe CT238A Instrukcja

13 Września 2024
Amprobe

Amprobe WT-20 Instrukcja

13 Września 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024