Instrukcja obsługi Amprobe ACD-3300-IND
Amprobe
Meetapparatuur
ACD-3300-IND
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Amprobe ACD-3300-IND (46 stron) w kategorii Meetapparatuur. Ta instrukcja była pomocna dla 8 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/46
ACD-3300 IND
ACDC-3400 IND
CAT IV Industrial True
RMS Clamp Meters
Users Manual
Mode d’emploi•
Bedienungshandbuch•
Manuale d’Uso•
Manual de uso•
Användarhandbok•
4
ACD-3300 IND / ACDC-3400 IND
CAT IV Industrial True RMS Clamp Meters
CoNTENTS
Symbols .................................................................................................................................. 5
Safety Information ................................................................................................................ 5
Warnings and Precautions ......................................................................................... 5
Unpacking and Contents ...................................................................................................... 6
Introduction ........................................................................................................................... 6
AUXILIARY FEATURES ........................................................................................................... 6
PEAK+/- Push button ....................................................................................................... 6
MAX/MIN Button ............................................................................................................. 6
ZERO (Relative) Measurements (ACDC-3400 IND only)............................................. 7
HOLD Button .................................................................................................................... 7
RANGE Button .................................................................................................................. 7
Backlight Push Button................................................................................................ 7
Auto Power Off (APO) ..................................................................................................... 7
Operation .............................................................................................................................. 7
Measuring DC Voltage (see Fig. 2) ............................................................................... 7
Measuring AC Voltage (See Fig. 2) ............................................................................... 7
AC Current Measurement (See Fig. 3) .......................................................................... 7
DC Current Measurement (ACDC-3400 IND only) (See Fig. 3) .................................... 7
Frequency Measurement / % Duty Cycle (see ig. 2) ................................................. 8F
Capacitance Measurement (see ig. 4) ......................................................................... 8F
Resistance (See Fig. 5) .................................................................................................. 8
Continuity Testing (See Fig. 5) ...................................................................................... 8
Diode Testing (See Fig. 5) ............................................................................................. 8
Temperature Measurement (ACD 3300 IND only) (See Fig. 6) ................................. 9
Maintenance and Repair ..................................................................................................... 9
Battery Replacement (see Fig. 7) ................................................................................. 9
Specifications ......................................................................................................................... 9
General ............................................................................................................................. 9
Electrical ......................................................................................................................... 10
8
Press the 2. button to null out the DC amps offset.
Open spring-loaded clamp by pressing the lever on left side of meter.3.
Position clamp around one wire or conductor and release the clamp lever. Wire 4.
should be center inside the jaws.
Read the displayed value.5.
Frequency Measurement / % Duty Cycle (see ig. 2) F
Select the “Hz” position. 1.
Connect the test leads: Red to 2. , Black to .+ COM
Connect the test probes to the circuit test points.3.
Read the frequency on the primary display and the Duty cycle on the secondary 4.
display, and, if necessary, correct any overload ( ) conditions.0L
Capacitance Measurement (see ig. 4)F
Note: When the capacitor to be tested is connected and LCD indicates “di .c”, means
there is voltage on the capacitor and needs to be discharged before testing.
Select the “1. ” position.
Connect the test leads: Red to 2. , Black to .+ COM
Connect the test probes to the circuit test points.3.
Read the display and if necessary, correct any overload (4. ) conditions.0L
CAUTION
Using the Resistance or Continuity function in a live circuit will produce false results
and may damage the instrument. In most cases the suspected component must be
disconnected from the circuit to obtain an accurate measurement reading.
Resistance (See Fig. 5)
Set the Function Switch to 1. . Use the ‘ ’ button to select the resistance test Ω Ω
(ACD-3300 IND only).
Connect the test leads: Red to 2. , Black to .+ COM
Turn off power to the circuit being measured. Never measure resistance across a 3.
voltage source or on a powered circuit.
Discharge any capacitors that may influence the reading.4.
Connect the test probes across the resistance.5.
Read the display. If 6. appears on the highest Range, the resistance is too large to be 0L
measured or the circuit is an open circuit.
Continuity Testing (See Fig. 5)
Set the Function Switch to 1. . Use the ‘ ’ button to select the test (ACD-3300 Ω
IND only).
Connect the test leads: Red to 2. , Black to .+ COM
Turn off power to the circuit being measured.3.
Discharge any capacitors that may influence the reading.4.
Connect the test probes across the resistance or the two points of test.5.
Listen for the tone that indicates continuity (< 30 6. ).Ω
Diode Testing (See Fig. 5)
Set the Function knob to the “ 1. “ position. Use the ‘ ’ button to select diode Ω
test (ACD-3300 IND only).
Connect the red test lead to the “V2. ” jack and the black test lead to the “COM” Ω
jack.
Turn off power to the circuit under test. External voltage across the components 3.
causes invalid readings.
Touch probes to the diode. A forward-voltage drop is about 0.6V (typical for a silicon 4.
diode).
Specyfikacje produktu
Marka: | Amprobe |
Kategoria: | Meetapparatuur |
Model: | ACD-3300-IND |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Amprobe ACD-3300-IND, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Meetapparatuur Amprobe
25 Sierpnia 2024
15 Sierpnia 2024
8 Sierpnia 2024
4 Lipca 2024
Instrukcje Meetapparatuur
- Meetapparatuur Beurer
- Meetapparatuur Pioneer
- Meetapparatuur Voltcraft
- Meetapparatuur Black & Decker
- Meetapparatuur Silverline
- Meetapparatuur Testo
- Meetapparatuur TFA
- Meetapparatuur Chauvin Arnoux
- Meetapparatuur Uni-T
- Meetapparatuur Dahua Technology
- Meetapparatuur Techno Line
- Meetapparatuur Perel
- Meetapparatuur Trotec
- Meetapparatuur Velleman
- Meetapparatuur Güde
- Meetapparatuur Gossen Metrawatt
- Meetapparatuur Fluke
- Meetapparatuur Megger
- Meetapparatuur Greisinger
- Meetapparatuur Continental Edison
- Meetapparatuur TDE Instruments
- Meetapparatuur Bresser
- Meetapparatuur Omnitronic
- Meetapparatuur Eltako
- Meetapparatuur Hager
- Meetapparatuur Extech
- Meetapparatuur Testboy
- Meetapparatuur Kyoritsu
- Meetapparatuur Vemer
- Meetapparatuur Klein Tools
- Meetapparatuur Ridgid
- Meetapparatuur Lanaform
- Meetapparatuur Emko
- Meetapparatuur Powerfix
- Meetapparatuur ADE
- Meetapparatuur ProfiCare
- Meetapparatuur Toolland
- Meetapparatuur Flir
- Meetapparatuur Finder
- Meetapparatuur Fantini Cosmi
- Meetapparatuur REV
- Meetapparatuur Peak
- Meetapparatuur X-Rite
- Meetapparatuur Tru Components
- Meetapparatuur Delta Ohm
- Meetapparatuur Hanna
- Meetapparatuur MGL Avionics
- Meetapparatuur UHoo
Najnowsze instrukcje dla Meetapparatuur
19 Września 2024
19 Września 2024
19 Września 2024
18 Września 2024
18 Września 2024
18 Września 2024
17 Września 2024
17 Września 2024
17 Września 2024
17 Września 2024