Instrukcja obsługi Air King AS70


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Air King AS70 (8 stron) w kategorii Wentylator. Ta instrukcja była pomocna dla 2 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/8
IMPORTANT INSTRUCTIONS -
OPERATING MANUAL
SAVE THESE INSTRUCTIONS
www.airkinglimited.com
210572050 Rev. H 12-15 1 of 8
Exhaust Fan
Models:
AS50, AS60, AS70, AS54
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN
THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL
INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock and
injury to person, including the following:
WARNING: TO REDUCE THE RISK
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If you have
questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
WARNING: TO REDUCE THE RISK
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualied
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment manufacturers guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA) and the American Society for Heating,
Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
CAUTION: FOR GENERAL VENTILATING USE ONLY.
DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS AND VAPORS.
d) Ducted fans must always be vented to the outdoors.
e) This unit must be grounded.
f) To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
g) Read all instructions before installing or using exhaust fan.
WARNING: TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, DO NOT USE THIS FAN WITH
ANY SOLID-STATE SPEED CONTROL DEVICE.
a) Acceptable for use over a bathtub or shower when installed in a
GFCI protected branch circuit.
WARNING: DO NOT USE IN KITCHENS.
INSTALLATION INSTRUCTIONS
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE STARTING INSTALLATION.
SECTION 1
Preparing the Exhaust Fan
1. Unpack fan from the carton and confirm that all pieces are present. In addition to the
exhaust fan you should have:
1 - Grill
1 - Damper Assembly (attached)
1 - Knockout Plug
1 - Instruction/Safety Sheet
2. Remove the fan’s venturi assembly, which is secured in place with one screw through the
venturi (Figure 1). This is a captive screw and will stay installed in the venturi. Keep the
venturi assembly and the grill in the carton until needed so they do not get damaged or lost.
3. Choose the location for your fan. To ensure the best
air and sound performance, it is recommended that
the length of ducting and the number of elbows be
kept to a minimum, and that insulated hard ducting
be used. Larger duct sizes will reduce noise and
airflow restrictions.
4. Select the most convenient electrical knockout hole
and insert the knockout plug into the 2nd knockout
hole (Figure 2).
SECTION 2
New Construction
1. Using the gauge on the fan’s housing , line up housing so that it will be flush with (Figure 3)
the finished ceiling or wall. Position the fan so that the tabs rest flat against the joist or stud
and secure with four nails (not provided) to ensure proper installation.
SECTION 3
Existing Construction
1. Position housing against the joist or stud and trace an outline of the housing onto the
ceiling/wall material Set housing aside and cut opening, being careful not (Figure 4).
to cut or damage any electrical or other hidden utilities. Place housing next to the joist
or stud and insure that it is flush with the finished ceiling. Secure with four nails (not
provided) to ensure proper installation (Figure 3).
www.airkinglimited.com
210572050 Rev. H 12-15 2 of 8
SECTION 4
Ducting
CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL
BUILDING CODES.
1. Connect the ducting to the fan’s duct collar . Secure in place using tape or (Figure 4)
screw clamp. Always duct the fan to the outside through a wall or roof cap.
NOTE: If damper detaches from unit, reattach by snapping the collar back onto the unit. It is
designed to only fit one way.
SECTION 5
Wiring
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE STARTING INSTALLATION.
CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE
MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR
NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING
ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.
1. Run wiring from an approved wall switch carrying the appropriate rating. One neutral (white),
one ground (green or bare copper), and one hot (black lead connected to the switch). Secure
the electrical wires to the housing with an approved electrical connector. Make sure you
leave enough wiring in the box to make the connection to the fan’s receptacle.
2. From where you have access to inside the fan’s junction box, connect the White wire from
the house to the White wire from the fan’s receptacle. Connect the Black wire from the
wall switch to the Black wire from the fan’s receptacle. Connect the ground wire from the
house to the Green wire from the fan’s receptacle . Use approved methods for (Figure 6)
all connections.
Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Supply
from
house
Figure 6
White Hot (Black)
Ground
SECTION 6
Completing the Installation
1. Reinstall the fan’s venturi by holding it at approximately a 45 degree angle, hook the two
tabs on the venturi into the slots on the housing and secure in place by tightening the
venturi screw. Rotate the blower wheel by hand to ensure it spins freely. Now plug the
fan motor into the receptacle (Figure 7).
2. Install the grill by squeezing the two ends of the springs together and installing them up
into the slots of the fan’s venturi. Push the grill up into position (Figure 8).
3. Restore power and test your installation.
www.airkinglimited.com
210572050 Rev. H 12-15 3 of 8
SECTION 7
Use and Care
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE STARTING INSTALLATION.
1. Cleaning the Grill: Remove grill and use a mild detergent, such as dishwashing liquid,
and dry with a soft cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS.
Completely dry grill before reinstalling. Refer to instructions in Section 6 Finishing the
Installation, to reinstall grill.
2. Cleaning the Fan Assembly: Unplug the motor cord from receptacle and loosen the
venturi screw to remove the venturi from the unit. Wipe all parts with a dry cloth or gently
vacuum the fan. NEVER IMMERSE ELECTRICAL PARTS IN WATER. Refer to instructions in
Section 6 ,, to reinstall venturi.Finishing the Installation
CALIFORNIA RESIDENTS ONLY:
WARNING: THIS PRODUCT CAN EXPOSE YOU TO A CHEMICAL [OR
CHEMICALS] KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER.
WARNING: THIS PRODUCT CAN EXPOSE YOU TO A CHEMICAL
[OR CHEMICALS] KNOWN TO THE STATE OF CALIFORNIA TO CAUSE
REPRODUCTIVE TOXICITY.
Figure 7
Figure 8
Troubleshooting Guide
Trouble Probable Cause Suggested Remedy
1. Fan does not operate when the switch is on. 1a. A fuse may be blown or a circuit tripped. 1a. Replace fuse or reset circuit breaker.
1b. Connector plug from motor is not plugged in. 1b. Turn off power to unit. Remove Grill and plug motor into receptacle
in housing. Restore power to unit.
1c. Wiring is not connected properly. 1c. Turn off power to unit. Check that all wires are connected.
1d. Motor has stopped operating. 1d. Replace motor.
2. Fan is operating, but air moves slower than normal. 2. Obstruction in the exhaust ducting. 2. Check for any obstructions in the ducting. The most common are bird nests
in the roof cap or wall cap where the fan exhausts to the outside.
3. Fan is operating louder than normal. 3a. Motor is loose. 3a. Turn off power to unit. Remove grill and check that all screws are fully
tightened. Restore power to unit.
3b. Fan blade is hitting housing of unit. 3b. Call your dealer for service.


Specyfikacje produktu

Marka: Air King
Kategoria: Wentylator
Model: AS70

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Air King AS70, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Wentylator Air King

Air King

Air King E130SH Instrukcja

10 Października 2024
Air King

Air King AK100L Instrukcja

27 Września 2024
Air King

Air King 9071 Instrukcja

23 Września 2024
Air King

Air King 9145 Instrukcja

23 Września 2024
Air King

Air King 9723 Instrukcja

22 Września 2024
Air King

Air King 9312 Instrukcja

21 Września 2024
Air King

Air King 9018 Instrukcja

15 Września 2024
Air King

Air King AKLC703 Instrukcja

13 Września 2024
Air King

Air King 9130 Instrukcja

13 Września 2024
Air King

Air King 9170 Instrukcja

13 Września 2024

Instrukcje Wentylator

Najnowsze instrukcje dla Wentylator

TriStar

TriStar VE-5936 Instrukcja

10 Października 2024
Orbegozo

Orbegozo PW 1321 Instrukcja

10 Października 2024
Thermex

Thermex Silent 100 CZ Instrukcja

9 Października 2024
Imarflex

Imarflex IF-375BU Instrukcja

9 Października 2024
Imarflex

Imarflex IF-365BK Instrukcja

9 Października 2024
Kogan

Kogan KARCDCFANLA Instrukcja

9 Października 2024
Westinghouse

Westinghouse 72206 Instrukcja

9 Października 2024
Westinghouse

Westinghouse 78425 Instrukcja

9 Października 2024
Westinghouse

Westinghouse 72076 Instrukcja

9 Października 2024