Oscillating Dimensions and Specications
99533 24” 14 1/2” 26 3/4” 120 60 3 3 Pedestal
99532 30” 14 1/2” 33 3/8” 120 60 3 3 Pedestal
2
Prop.
Model Dia. A B Volts Hz Speeds Blades Mounting Accessory
99533 24” 1025/880/480 1/4 5030 4320 2280 500/350/220 7.7/5.7/1.8 2.3/1.6/0.6 3.5
99532 30” 1010/860/530 1/4 7450 6090 3450 700/520/300 6.7/5.4/2.0 2.3/1.6/0.6 3.7
Prop. Motor CFM Air Velocity Sones @ Operating Full Load
Model Dia. RPM HP High Med Low @ 20 Ft. (FPM) 0.000SP Amps Amps
2
Operating Instructions & Parts Manual Models 99533, 99532
PLEASE READ AND SAVE THESE INSTRUCTIONS. Read carefully before attempting to assemble, install, operate or
maintain the product described. Protect yourself and others by observing all safety information. Failure to comply
with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
Description
Designed for cooling workers in factories, warehouses, manufacturing facilities and garages where
humid and demanding conditions exist. All circulator heads have high efciency corrosion resistant
propellers with steel blades. Circulator heads utilize a vertical tilt/locking adjustment for directional
ow. Wire guards are black power-coated steel and comply with OSHA Standard 1910.212 (1/2”
maximum opening). All circulator heads are oscillating that sweep through a 45 or 90 arc.° °
24” & 30” Quiet Design
Oscillating Pedestal Fan
Unpacking
1. Inspect for any damage that may have occurred during transit.
2. Shipping damage claim must be led with carrier.
3. Check all bolts, screws, setscrews, etc. for looseness that
may have occurred during transit. Retighten as needed.
Printed in U.S.A. New 5/11 5085460
A
1. Read all instructions before using Fan.
2. Make certain that the power source con-
forms to the electrical requirements of the
Fan.
3. Use this Fan only as described in this manual.
Any other use not recommended by the
manufacturer may cause re, electrical shock,
or injury to persons.
4. To reduce the risk of personal injury and elec-
tric shock, the Fan should not be played with
or placed where small children can reach it.
5. Unplug power cord before servicing, or
moving the Fan.
WARNING: DO NOT DEPEND UPON THE
ON-OFF SWITCH AS THE SOLE MEANS OF
DISCONNECTING POWER WHEN INSTALLING
OR SERVICING THE FAN. ALWAYS UNPLUG
THE POWER CORD.
6. This Fan must NOT be used in potentially
dangerous locations such as ammable,
e xp l o s i ve , ch e mi c a l - l a d e n or we t
a t mo spheres.
7. DO NOT use Fan in or near a window. Rain
may create an electrical hazard.
8. Completely reassemble Fan, according
to instructions, before reconnecting to
power supply.
9. The power cord is equipped with a three-
prong grounded plug that be inserted should
into a matching receptacle. Under no
circumstances should the grounding prong
be cut off the plug. Where a two-prong
wall receptacle is encountered, it must be
replaced with a properly grounded three-
prong receptacle installed in accordance
with the National Electrical Code (NEC) and
all applicable local codes and ordinances.
This work must be done only by a qualied
electrician, using copper wire only.
WARNING: USE OF A THREE-PRONG TO TWO-
PRONG ADAPTER IS NOT RECOMMENDED.
IMPROPER CONNECTION MAY CREATE THE
GENERAL SAFETY INFORMATION
When using electrical appliances,
basic precautions should always
be followed to reduce the risk of
re, electric shock and injury to
person, including the following:
RISK OF ELECTRICAL SHOCK. USE OF
SUCH ADAPTERS NOT PERMITTED IS
IN CANADA.
10. Where possible, avoid the use of
extension cords. If they must be used,
minimize the risk of overheating by
ensuring that they are UL listed. Never
use a single extension cord to operate
more than one Fan. Do not plug Fan
into any other cord connected device,
such as a power strip, cord reel, surge
protector, multiple outlet adapters or
outlet-type air fresheners. The use of
such devices may create a re hazard.
11. Do not operate any Fan with a
damaged cord or plug or after the
Fan malfunctions, has been dropped
or damaged in any manner. Return
Fan to authorized service facility for
examination, electrical or mechanical
adjustment or repair.
12. Do not insert or allow ngers or foreign
objects to enter any ventilation or
exhaust opening as it may cause an
electric shock or re, or damage the
Fan. Do not block or tamper with
the Fan in any manner while it is in
operation.
13.Locate the Power Cord so the Fan or
other objects are not resting on it. Do not
run Power Cord under carpeting or oor
mats. Do not cover Power Cord with
runners, or the like. Do not run Power
Cord through doorways, windows or
areas where cord impingement may
occur. Arrange Power Cord away from
room trafc and where it will not be
tripped over.
14.This Fan is not intended for use in
wet or damp locations. Never locate
a Fan where it may fall into water.
15. Do not use Fan outdoors.
16.This Fan is not suitable for use in
hazardous locations. Please refer to
National Electric Code (NEC) Article
500 or applicable state or local codes
or standards relating to electrical
requirements for Hazardous locations.
THIS FAN DOES NOT MEET THE
REQUIREMENTS OF NEC ARTICLE
500 (2008).
24” & 30” Quiet Design
Oscillating Pedestal Fan
2
WARNING: REDUCE THE RISK OF FIRE OR
ELECTRIC SHOCK DO NOT USE THIS FAN
WITH ANY SOLID STATE SPEED CONTROL
DEVICES.
CAUTION: BECAUSE OF THE SIZE AND
WEIGHT OF THIS FAN, MAKE SURE ALL
PARTS ARE COMPLETELY ASSEMBLED
ACCORDING TO INSTRUCTIONS. FAILURE
TO DO SO COULD RESULT IN FAN
COMING APART DURING OPERATION
AND/OR PERSONAL INJURY.
Operating Instructions & Parts Manual 99533/99532
5085460New 5/11
3 5085460New 5/11
Locate remaining parts from Motor Hardware Bag
to Assemble Grills and Blade to the Motor.
1. Install the Rear Grill onto the Motor, lining up
the six holes in the grill with the six threaded
holes in the motor mounting ange. Install (6)
10-32 X 5/16Hex Screws through the rear
grill into the grill mounting ange. Securely
tighten all (6) screws. (Figure 3)
2. Push the Fan Blade onto the Motor Shaft,
centering the Hub facing away from the
motor, until it stops against the shaft (Inset
A) . Align Square Head Bolt with at of the
motor shaft. TIGHTEN VERY SECURELY
WITH AN ADJUSTABLE WRENCH. Failure
to securely tighten the Bolt could result in
damage to the Fan and/or personal injury.
3. Hold the Front Grill so that the name, in the
center, is right side up and straight across.
Starting at the top: Fasten Front Grill to
Rear Grill by sliding the hooked wires on
the Front Grill over the outermost ring on
the Rear Grill. . The (Figure 4 / Detail A)
bottom most hooks will require the use of a
athead screwdriver to complete assembly.
Stand behind the Fan. Slip the at of the
screwdriver between the Front and Rear
Grills, next to one of the unfastened hooks.
(Figure 4 / Detail B) Pull screwdriver handle
upwards towards the Rear Grill. Slip the Front
Grill hook over the Rear Grill outer ring with
a push. Repeat procedure with remaining
hooks.
CAUTION: DO NOT BEND WIRES ON THE
FRONT OR THE REAR GRILLS.
GRILL AND BLADE ASSEMBLY
Figure 3
Inset A
Figure 4
Detail A
Detail B
COLUMN/MOTOR TO BASE/
ASSEMBLY
1. Rest Column and Motor Assembly on oor next
to the Base Assembly. Tilt Base Assembly up on
end. Pick up lower pipe of Column Assembly and
insert into the Mounting Flange. (Figure 2)
2. Loosen (2) 3/8-16 X 3/8 Allan Head Bolt in the
Mounting Flange. This will allow the Column to
settle in the bottom of the Base after setting the
Fan upright.
3. Tilt entire assembly to the upright position.
MAKE SURE BOLTS IN COLUMN AND
MOTOR ASSEMBLY STEPS ARE TIGHT
BEFORE STANDING FAN UPRIGHT.
4. Tighten the (2) 3/8-16 X 3/8 Allen Head Bolt in
the Mounting Flange.
Figure 2
Figure 1
Actual motor not shown for
detailed hardware view.
GRILL AND BLADE ASSEMBLY
CONTINUED
COLUMN AND MOTOR
ASSEMBLY
Locate Motor Hardware Bag to
Assemble Column and Motor Assembly.
1. Place at section on Upper Tube of Column
Assembly next to Neck on Motor Assembly.
Align the 1/2diameter hole in the at section
on the Upper Tube ofColumn Assembly with
the 1/2” diameter hole in the Motor Assembly.
(Figure 1)
2. Insert the 1/2 X 1” Hex Bolt (3/4” head)
through the Motor Neck, and the Upper
Tube Assembly. Place 1/2” diameter Split
Lockwasher then the 1/2” diameter Hex Nut
(3/4” head) and tighten fully with a adjustable
wrench. (Figure 1)
3. From the same side of the Motor Neck,insert
one 1/4-20 X 1 5/8Carriage Bolt through
the Arc-Shaped Slot in the Motor Neck and
Hole in the Upper Pipe of Column Assembly.
(Figure 1)
4. Attach pull string to motor speed switch, if
desired.


Specyfikacje produktu

Marka: Air King
Kategoria: Wentylator
Model: 99532

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Air King 99532, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Wentylator Air King

Air King

Air King E130SH Instrukcja

10 Października 2024
Air King

Air King AK100L Instrukcja

27 Września 2024
Air King

Air King 9071 Instrukcja

23 Września 2024
Air King

Air King 9145 Instrukcja

23 Września 2024
Air King

Air King 9723 Instrukcja

22 Września 2024
Air King

Air King 9312 Instrukcja

21 Września 2024
Air King

Air King 9018 Instrukcja

15 Września 2024
Air King

Air King AKLC703 Instrukcja

13 Września 2024
Air King

Air King 9130 Instrukcja

13 Września 2024
Air King

Air King 9170 Instrukcja

13 Września 2024

Instrukcje Wentylator

Najnowsze instrukcje dla Wentylator

TriStar

TriStar VE-5936 Instrukcja

10 Października 2024
Orbegozo

Orbegozo PW 1321 Instrukcja

10 Października 2024
Thermex

Thermex Silent 100 CZ Instrukcja

9 Października 2024
Imarflex

Imarflex IF-375BU Instrukcja

9 Października 2024
Imarflex

Imarflex IF-365BK Instrukcja

9 Października 2024
Kogan

Kogan KARCDCFANLA Instrukcja

9 Października 2024
Westinghouse

Westinghouse 72206 Instrukcja

9 Października 2024
Westinghouse

Westinghouse 78425 Instrukcja

9 Października 2024
Westinghouse

Westinghouse 72076 Instrukcja

9 Października 2024