Instrukcja obsługi Air King 9418
Air King
Ventilator
9418
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Air King 9418 (8 stron) w kategorii Ventilator. Ta instrukcja była pomocna dla 4 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/8
18" PEDESTAL FAN
18" (45.7 cm) MODEL 9418
1
Rev. A 11/05 5084034
DESCRIPTION
The AirKing 18" (45.7 cm) pedestal fan features 3-speed rotary knob
operation with a 3-paddle fan blade and variable height adjustments.
This fan has a permanently lubricated motor with a 9 ft. (2.74 m) 18/3 cord
set and is constructed of sturdy, powder coated steel.
SPECIFICATIONS
Motor ....................................... 120 V, 60 Hz
Blade diameter ....................... 18" (45.7 cm)
Speeds .................................... 3
Control .................................... Rotary Switch
Air flow distribution ................. 360°
Approvals ................................ UL Listed. Close mesh fan guard
meets OSHA requirements.
ASSEMBLY
TOOLS REQUIRED FOR ASSEMBLY
• Hex Wrench (Supplied in Parts Bag)
NOTE: ALL HARDWARE REFERRED TO IN THE INSTRUCTIONS MAY
BE FOUND IN THE SUPPLIED PARTS BAG.
1. Lay Fan Head on flat surface, so the front side is facing down. Hold Yoke
so the side with the n ut is facing up. Loosely attach one Gr ill Knob and
one Rubber Spacer to the Head Assemb ly. Attach the other Gr ill Knob
and Rubber Spacer to the Head Assembly and FIRMLY tighten. Return to
the first Grill Knob and FIRMLY tighten.
(Figure 1)
NOTE: THE UPPER PIPE HAS 2 BUMPS, ONE AT EACH END. THE BUMP
CLOSER TO THE END OF THE PIPE INDICATES THE TOP. THIS END
FITS INTO THE YOKE.
2. Make sure Bump on Upper Pipe is aligned with formed section of Yoke.
Insert Upper Pipe into Yoke. To ensure fit is tight, twist Upper Pipe until it
is tight inside of Yoke.
(Figure 1)
NOTE: THE UPPER PIPE SHOULD FIT COMPLETELY INSIDE OF THE YOKE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic pr e-
cautions should always be followed to reduce
the risk of fir e, electric shock and injur y to
person, including the following:
1. Read all instructions before using Fan.
2. Make certain that the power source conforms to the electrical
requirements of the Fan.
3. Use this Fan only as described in this manual. Any other use
not recommended by the manufacturer may cause fire, electrical
shock, or injury to persons.
5. Unplug power cord before installing, servicing, or moving the Fan.
WARNING: DO NOT DEPEND UPON THE ON-OFF
SWITCH AS THE SOLE MEANS OF DISCONNECTING
POWER WHEN INSTALLING OR SERVICING THE FAN.
ALWAYS UNPLUG THE POWER CORD.
6. This Fan must NOT be used in potentially dangerous
locations such as flammable, explosive, chemical-laden
or wet atmospheres.
7. The power cord is equipped with a three-prong grounded plug
that must be inserted into a matching receptacle. Under no
circumstances must the grounding prong be cut off the plug.
Where a two-prong wall receptacle is encountered, it must be
replaced with a properly grounded three-prong receptacle
installed in accordance with the National Electrical Code
(NEC) and all applicable local codes and ordinances. This
work must be done only by a qualified electrician, using copper
wire only.
WARNING: USE OF A THREE-PRONG TO TWO-PRONG
ADAPTER IS NOT RECOMMENDED. IMPROPER CONNEC-
TION MAY CREATE THE RISK OF ELECTROCUTION. USE
OF SUCH ADAPTERS IS NOT PERMITTED IN CANADA.
WARNING: THIS PLUG IS A SAFETY FEA TURE. TO
REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND
PERSONAL INJURY, DO NO T REMOVE, REPLACE,
REPAIR OR TAMPER WITH THE ORIGINALLY SUPPLIED
PLUG. IF THE FAN DOES NOT FUNCTION PROPERLY,
IT MAY BE DUE TO THE SAFETY DEVICE
INCORPORATED IN THIS PLUG. RETURN TO AN
AUTHORIZED SERVICE CENTER OR CALL 800-233-0268,
MONDAY - FRIDAY, BETWEEN 8:00 AM AND 5:00 PM EST.
IF THE PLUG WARNING LABEL IS MISSING OR
DAMAGED, CALL THE TOLL FREE NUMBER FOR A
REPLACEMENT LABEL.
8. Where possible, avoid the use of extension cords. If they must
be used, minimize the risk of overheating by ensuring that they
are UL listed. Never use a single extension cord to operate more
than one Fan.
9. Do not operate any Fan with a damaged cord or plug after the
Fan malfunctions, has been dropped or damaged in any manner.
Return Fan to authorized service facility for examination, electrical
or mechanical adjustment or repair.
10.Do not inser t or allo w fingers or f oreign objects to enter an y
ventilation or exhaust opening as it may cause an electric shock,
fire, or damage the Fan. Do not block or tamper with the Fan in
any manner while it is in operation.
11.Always place the Fan on a stable, flat, level surface when
operating, to avoid the chance of the Fan overturning. Locate
the Power Cord so the Fan or other objects are not resting on it.
Do not run Power Cord under carpeting. Do not cover Power
Cord with throw rugs, runners, or the like. Arrange Power Cord
away from room traffic and where it will not be tripped over.
12.This Fan is not intended for use in wet or damp locations.
Never locate a Fan where it may fall into a bathtub or other
water container.
13. Do not use Fan outdoors.
WARNING: REDUCE THE RISK OF FIRE OR ELECTRIC
SHOCK – DO NOT USE THIS FAN WITH ANY SOLID STATE
SPEED CONTROL DEVICES.
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT
DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO
COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
OPERATING INSTRUCTIONS & PARTS MANUAL
SAVE THESE
INSTRUCTIONS
MODEL 9418
Rev. A 11/05 2
CAUTION: TO AVOID INJURY, MAKE SURE UPPER PIPE/F AN
HEAD IS SUPPORTED WHEN INSERTING INTO BOTTOM PIPE
OR ADJUSTING HEIGHT.
4. Make sure Bump on Upper Pipe is aligned with f ormed section
of Lower Pipe. Insert Upper Pipe/Fan Assembly into Lower Pipe
and allow it to slide to the bottom of the Lo wer Pipe. Screw a
3.
Attach Lower Pipe to Base using Bolt and Split Loc kwasher.
(Figure 2)
FIRMLY tighten with supplied Hex Wrench.
Pipe Knob into Lo wer Pipe until it loosely touches the Upper
Pipe. Raise Upper Pipe/F an Assembly to desired height and
FIRMLY tighten Pipe Knob.
OPERATION
1. To Adjust Height: While holding Top Pipe and Fan Head firmly,
loosen Lower Pipe Knob. Adjust Fan up or down to desired height
and FIRMLY retighten Pipe Knob.
CAUTION: LAY FAN ON ITS SIDE OR HOLD TOP OF FAN
FIRMLY WHEN ADJUSTING HEIGHT. INJURY MAY OCCUR
IF FAN IS NOT SUPPORTED.
2. To Adjust Head Angle: While holding Head fir mly, loosen Grill
Knobs on each side of the Yoke (turn counterclockwise). Tilt Head
to desired position and FIRMLY retighten Grill Knobs.
3. To Operate: Plug cord into a grounded 120 V, 60 Hz outlet. Select
desired operating speed with Selector on back of Fan.
4. WARNING: This fan should be used only in a clean, dry environ-
ment. mounting of this product in any way other than specified in
the instruction sheet will null and void the manufacturers war-
ranty.
MAINTENANCE
WARNING: ALWAYS UNPLUG THE CORD BEFORE SERVICING.
CLEANING: Use a soft cloth and a mild soap solution such as
liquid dish washing detergent.
CAUTION: Do not use gasoline, benzine, thinner, harsh clean-
ers, etc. which will damage the fan.
Dry all parts with a soft cloth completely before reconnecting to
power supply.
STORAGE: When not in use, keep unit in a clean dry place.
MOTOR IS PERMANENTLY LUBRICATED.
Figure 2
Lower Pipe
Bolt
Base
5/16" Split Lockwasher
5084034
AIRKING THREE-YEAR LIMITED WARRANTY. Products are warranted by AirKing to the original user against defects in workmanship
or materials under normal use for three years on the motor and one year on all other parts, after date of purchase. Any part wh ich is
determined by AirKing to be detective in material or workmanship and returned to an authorized service location, as AirKing designates,
shipping costs prepaid, will be, as the exclusive remedy, repaired or replaced at AirKing’s option. For limited warranty claim procedures,
see PROMPT DISPOSITION below. This limited warranty gives purchasers specific legal rights which vary from state to state.
LIMITATION OF LIABILITY. To the extent allowable under applicable law. AirKing’s liability for consequential and incidental damages
is expressly disclaimed. AirKing’s liability in all events is limited to, and shall not exceed, the purchase price.
WARRANTY DISCLAIMER. AirKing has made a diligent effort to illustrate and describe the products in this literature accurately; however,
such illustrations and descriptions are for the sole purpose of identification, and do not express or imply a warranty the prod ucts are
merchantable, or fit a particular purpose, or that the products will necessarily conform to the illustrations or descriptions. Except as
provided below, no warranty or affirmation of fact, expressed or implied, other than as stated in “LIMITED WARRANTY” above is made
or authorized by AirKing.
PRODUCT SUITABILITY. Many states and locations have codes and regulations governing sales, construction, installation, and/or use
of products for certain purposes, which may vary from those in neighboring areas. While AirKing attempts to assure that its pro ducts
comply with such codes, it cannot guarantee compliance, and cannot be responsible for how the product is installed or used. Bef ore
purchase and use of a product, please review the product application, and national and local codes and regulations, and be sure that the
product, installation, and use will comply with them.
Certain aspects of disclaimers are not applicable to consumer products; e.g., (a) some states do not allow the exclusion or limitation of
incidental or consequential damages, so the above limitation or exclusion may not apply to you; (b) also, some states do not al low
limitations on how long an implied warranty lasts, consequently the above limitation may not apply to you; and (c) by law, during the period
of the Limited Warranty, and implied warranties of merchantability or fitness for a particular purpose applicable to consumer products
purchased by consumers, may not be excluded or otherwise disclaimed.
PROMPT DISPOSITION. AirKing will make a good faith effort for prompt correction or other adjustment with respect to any product which
proves to be defective within limited warranty. For any product believed to be defective within limited warranty, first write or call dealer
from whom product was purchased. Dealer will give additional directions.
LIMITED WARRANTY
Figure 1
Upper Pipe
Pipe Knob (Small)
Yo k e
Bumps
Rubber Spacer
Specyfikacje produktu
Marka: | Air King |
Kategoria: | Ventilator |
Model: | 9418 |
Kolor produktu: | Black,Stainless steel |
Materiał obudowy: | Stal nierdzewna |
Typ kontroli: | obrotowy |
Wbudowany wyświetlacz: | Tak |
Łatwy do czyszczenia: | Tak |
Długość przewodu: | 1.2 m |
Typ wyświetlacza: | LED |
Położenie urządzenia: | Wbudowany |
Częstotliwość wejściowa AC: | 50/60 Hz |
Napięcie wejściowe AC: | 220 - 240 V |
Wysokość produktu: | 595 mm |
Szerokość produktu: | 594 mm |
Głębokość produktu: | 548 mm |
Waga produktu: | 31389 g |
Szybkie nagrzewanie: | Tak |
Szerokość opakowania: | 690 mm |
Wysokość opakowania: | 675 mm |
Głębokość opakowania: | 660 mm |
Szerokość przedziału instalacji: | 568 mm |
Głębokość przedziału instalacji: | 550 mm |
Minimalna wysokość przedziału instalacji: | 595 mm |
Głębokość przy otwartych drzwiach: | 1040 mm |
Prąd: | 16 A |
Obciążenie: | 3400 W |
Klasa wydajności energetycznej: | A |
Skala efektywności energetycznej: | A +++ do D |
Zabezpieczenie przed dziećmi: | Tak |
Sterowanie przez Wi-Fi: | Nie |
Certyfikaty: | CE, VDE |
Zawias drzwiczek: | W dół |
Wysokość przedziału instalacji: | 585 mm |
Samoczyszczący: | Tak |
Liczba piekarników: | 1 |
Pojemność netto piekarnika: | 71 l |
Grill: | Tak |
Nagrzewanie przednie: | Tak |
Grzanie górne i dolne: | Tak |
Nagrzewanie dolne: | Tak |
Termoobieg: | Tak |
Standardowe gotowanie: | Tak |
Wskaźnik efektywności energetycznej: | 95.3 |
Zużycie energii (standard): | 0.97 kWh |
Zużycie energii (konwekcja wymuszona): | 0.81 kWh |
Funkcja utrzymywania temperatury: | Tak |
Typ piekarnika: | Kuchenka elektryczna |
Rozmiar piekarnika: | Średni |
Pojemność wnętrza wszystkich piekarników: | 71 l |
Łączna moc piekarnika: | - W |
Grill na całej powierzchni: | Tak |
Grillowanie gorącym powietrzem: | Tak |
Funkcja rozmrażania piekarnika: | Nie |
Wolne gotowanie: | Nie |
Gotowanie mikrofalowe: | Nie |
Gotowanie na parze: | Nie |
Technologia czyszczenia: | Hydrolityczny |
Chowane gałki: | Tak |
Chłodne drzwi: | Tak |
Materiał frontów: | Szkło |
Maksymalna temperatura drzwi: | 50 °C |
Szerokość przedziału instalacyjnego (min): | 560 mm |
Zintegrowany zegar: | Tak |
Rodzaj zegara: | Elektroniczny |
Pozycja panelu sterowania: | Przednie |
Maksymalna temperatura (konwekcja): | 275 °C |
Powierzchnia grillowa: | 1290 cm² |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Air King 9418, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Ventilator Air King
6 Września 2024
3 Września 2024
2 Września 2024
1 Września 2024
31 Sierpnia 2024
25 Sierpnia 2024
24 Sierpnia 2024
23 Sierpnia 2024
21 Sierpnia 2024
20 Sierpnia 2024
Instrukcje Ventilator
- Ventilator Tesy
- Ventilator DeLonghi
- Ventilator AEG
- Ventilator Beurer
- Ventilator Tefal
- Ventilator Livoo
- Ventilator SilverCrest
- Ventilator Infiniton
- Ventilator Panasonic
- Ventilator StarTech.com
- Ventilator Nedis
- Ventilator Stanley
- Ventilator Medion
- Ventilator Black & Decker
- Ventilator OK
- Ventilator Adler
- Ventilator Westinghouse
- Ventilator Domo
- Ventilator Ardes
- Ventilator Taurus
- Ventilator Orbegozo
- Ventilator Vivax
- Ventilator Stadler Form
- Ventilator Jocel
- Ventilator Bimar
- Ventilator Rowenta
- Ventilator Master
- Ventilator Honeywell
- Ventilator Fisher & Paykel
- Ventilator Tripp Lite
- Ventilator ECG
- Ventilator Unold
- Ventilator Antari
- Ventilator ORNO
- Ventilator Dyson
- Ventilator RYOBI
- Ventilator Gembird
- Ventilator Zelmer
- Ventilator Bomann
- Ventilator Teesa
- Ventilator Corsair
- Ventilator Emerio
- Ventilator H.Koenig
- Ventilator V-TAC
- Ventilator Eurolite
- Ventilator MPM
- Ventilator OneConcept
- Ventilator Thermex
- Ventilator Perel
- Ventilator Fagor
- Ventilator Trotec
- Ventilator Trumatic
- Ventilator Izzy
- Ventilator Klarstein
- Ventilator AFK
- Ventilator Camry
- Ventilator Steba
- Ventilator NewAir
- Ventilator Scarlett
- Ventilator TriStar
- Ventilator Dimplex
- Ventilator DCG
- Ventilator Vornado
- Ventilator G3 Ferrari
- Ventilator Clatronic
- Ventilator Inventum
- Ventilator SVAN
- Ventilator Princess
- Ventilator Innoliving
- Ventilator Sunbeam
- Ventilator Hama
- Ventilator Heller
- Ventilator Meaco
- Ventilator VOX
- Ventilator Solis
- Ventilator Frigidaire
- Ventilator Gemini
- Ventilator Thermaltake
- Ventilator Hunter
- Ventilator Martin
- Ventilator Gaggenau
- Ventilator Sencor
- Ventilator EasyMaxx
- Ventilator Fuave
- Ventilator Asko
- Ventilator Kalorik
- Ventilator Suntec
- Ventilator Be Quiet!
- Ventilator Grunkel
- Ventilator Cotech
- Ventilator Clas Ohlson
- Ventilator Lasko
- Ventilator Profile
- Ventilator Swan
- Ventilator Alpina
- Ventilator Andrews
- Ventilator Argo
- Ventilator Tomado
- Ventilator Sinbo
- Ventilator Itho
- Ventilator Mellerware
- Ventilator Heinner
- Ventilator Termozeta
- Ventilator Bionaire
- Ventilator White Knight
- Ventilator Evolar
- Ventilator Costway
- Ventilator Everglades
- Ventilator CasaFan
- Ventilator Duux
- Ventilator Gamma
- Ventilator Primo
- Ventilator Hema
- Ventilator Bulex
- Ventilator Team
- Ventilator Boneco
- Ventilator Tornado
- Ventilator Superior
- Ventilator Day
- Ventilator HQ
- Ventilator Fakir
- Ventilator Arno
- Ventilator Proklima
- Ventilator PAX
- Ventilator Orcon
- Ventilator Tron
- Ventilator Klarbach
- Ventilator Schweigen
- Ventilator Sichler
- Ventilator SMC
- Ventilator Portacool
- Ventilator Neo
- Ventilator Siku
- Ventilator O2 Cool
- Ventilator Elix
- Ventilator Casablanca
- Ventilator Wallair
- Ventilator Envira-North
- Ventilator Canarm
- Ventilator SEPA
Najnowsze instrukcje dla Ventilator
19 Września 2024
19 Września 2024
19 Września 2024
19 Września 2024
19 Września 2024
19 Września 2024
19 Września 2024
19 Września 2024
19 Września 2024
19 Września 2024