Instrukcja obsługi Aim TTi EL561R


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Aim TTi EL561R (30 stron) w kategorii nieskategoryzowany. Ta instrukcja była pomocna dla 12 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/30
EL-R SERIES
Linear Bench ies Power Suppl
1
Table of Contents
Introduction 2
Specification 2
Safety 4
Installation 5
Connections 6
Operation - Main Outputs 6
Operation Auxiliary Output 7
Operation General- 8
Maintenance 8
Instructions en Francais
Sécurité 9
Installation 10
Connexions 11
Fonctionnement - Sorties principales 11
Fonctionnement 12– S ortie Auxiliaire
Fonctionnement Généralités 13-
Maintenance 13
Bedienungsanleitung auf Deutsch
Sicherheit 14
Installation 15
Anschlüsse 16
Betrieb Hauptausgänge 16-
Betrieb Hilfsausgang 17
Betrieb - Allgemein 18
Wartung 18
Istruzioni in Italiano
Sicurezza 19
Installazione 20
Collegamenti 21
Funzionamento 21- Uscite principali
Funzionamento 22 Uscita Ausiliaria
Funzionamento Generale 23-
Manutenzione 23
Instrucciones en Español
Seguridad 24
Instalación 25
Conexiones 26
Operación 26- Salidas principales
Operación 27 Salida Auxiliar
Operación General 28-
Mantenimiento 28
2
Introduction
The EL series provides medium levels of power (up to 125 watts) in a compact and attractive -R
case style using linear regulation.
High resolution controls allow precise setting of voltage and current levels which are indicated on
accurate and highly legible digital meters.
Excellent line and load regulation is matched by very low noise and good transient response.
Improved power efficiency ensures that the units require no fan cooling. Remote sense terminals
are provided so that good regulation can be maintained across remote loads at high current.
The EL302RD has two independent isolated outputs each with a 0 to 30V, 0 to 2A capability. The
outputs operate in constant voltage or constant current mode with automatic crossover and mode
indication. Each output has its own on off switch. The outputs can be wired in either series or -
parallel to provide voltages up to 60 volts or currents up to 4 amps. The EL302RT has, in
addition, an Auxiliary ‘logic voltage’ output with a 2A current capability. This output can be preset
between 1.5 volts and 5 volts via a front panel control.
The EL155R, EL183R, EL301R, EL302R, EL303R and EL561R are single output supplies
capable of supplying up to 15V/5A, 18V/3.3A, 30V/1A, 30V/2A, 30V/3A or 56V/1.1A respectively.
The EL rporates separate digital voltage and current meters on each output. The -R series inco
meters use bright 14mm (0.56”) LED displays and have an update rate of 4 per second providing
near instantaneous response. Simultaneous metering of voltage and current provides accurate
information “at a glance” and avoids any possibility of misinterpretation. When an output switch is
set to “off”, the current limit setting is displayed enabling conditions to be set before the load is
connected. With the right hand main output off the hand meters can be used to - -right
momentarily display the preset Auxiliary voltage and current limit.
The EL R series has been designed to meet the stringent requirements of relevant IEC -
standards for safety and EMC. All outputs are intrinsically short circuit proof, and are protected
against external voltages and reverse currents.
Specification
MAIN OUTPUTS
Voltage Range: 0V to 15V minimum (EL155R)
0V to 18V minimum (EL183R)
0V to 30V minimum (EL301R, EL302R, EL303R, EL302RD, EL302RT)
0 to 56V minimum (EL561R)
Current Range: 0A to 1A minimum (EL301R)
0A to 1.1A minimum (EL561R)
0A to 2A minimum (EL302R, EL302RD, EL302RT)
0A to 3A minimum (EL303R)
0A to 3.3A minimum (EL183R)
0A to 5A minimum (EL155R)
Voltage Setting:
By coarse and fine controls.
Current Setting:
By single logarithmic control.
Operating Mode:
Constant voltage or constant current with automatic cross-over.
Output Switch:
Electronic. Preset voltage and current displayed when off.
Output Terminals:
Universal 4mm safety binding posts on 19mm (0.75”) pitch.
Sensing: Switchable between local and remote. Spring loaded push terminals for -
remote connection.
Output Protection: Outputs will withstand forward voltages of up to 20V above the rated
output voltage. Reverse protection by diode clamp for currents up to 3A.


Specyfikacje produktu

Marka: Aim TTi
Kategoria: nieskategoryzowany
Model: EL561R

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Aim TTi EL561R, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje nieskategoryzowany Aim TTi

Instrukcje nieskategoryzowany

Najnowsze instrukcje dla nieskategoryzowany

Meec Tools

Meec Tools 010-084 Instrukcja

6 Października 2024
Outwell

Outwell Scenic Road 250 Instrukcja

5 Października 2024
Impact

Impact QuikBalance Instrukcja

4 Października 2024
Impact

Impact CA-112 Instrukcja

4 Października 2024
Impact

Impact LS-BHA Instrukcja

4 Października 2024
Impact

Impact LKB-5C Instrukcja

4 Października 2024
Impact

Impact RST-001 Instrukcja

4 Października 2024